ICS55.040CCSA82T/CPF0028—2022/T/CSTE0018—2022产品质量分级及“领跑者”评价要求激光全息定位纸Productqualitygradingandforerunnerevaluationrequirements—Laserholographicpositionedpaper2022-04-01发布2022-04-01实施发布T/CPF0028—2022/T/CSTE0018—2022I目次前言·························································································································II1范围······················································································································12规范性引用文件······································································································13术语和定义············································································································14评价指标体系·········································································································15评价方法及等级划分································································································3附录A(规范性)甲醛、邻苯二甲酸酯总量、特定芳香胺总量的测定···································4T/CPF0028—2022/T/CSTE0018—2022II前言本文件按照GB/T1.1—2020《标准化工作导则第1部分:标准化文件的结构和起草规则》和T/CAQP015—2020、T/ESF0001—2020《“领跑者”标准编制通则》的规定起草。请注意本文件的某些内容可能涉及专利。本文件的发布机构不承担识别专利的责任。本文件由中国包装联合会和企业标准“领跑者”工作委员会提出。本文件由中国包装联合会和中国技术经济学会归口。本文件起草单位:中柔凹印技术服务(北京)中心、浙江亚欣包装材料有限公司、湖北宜美特全息科技有限公司、浙江三润新科技发展有限公司、深圳劲嘉集团股份有限公司、上海紫江喷铝环保材料有限公司、上海维凯光电新材料有限公司、海盐吉龙机械股份有限公司、绍兴虹鑫激光材料科技有限公司、苏大维格(盐城)光电科技有限公司、中丰田光电科技(珠海)有限公司、广州慧谷化学有限公司、上海睿途新材料科技有限公司、绍兴毅龙镭射科技有限公司、青岛澳科顺诚包装有限公司、广东邦固化学科技有限公司、武汉华工图像技术开发有限公司、绍兴虎彩激光材料科技有限公司、四川宜宾普拉斯包装材料有限公司、浙江京华激光科技股份有限公司、北京印刷学院。本文件主要起草人:汪名海、邵国良、李春阳、郝亚军、刘兵、王晓磊、段育歌、孔秀英、吕伟、李静、郭玉清、刘伟、朱立纲、董海普、谢允斌、王紫君、廖界丰、曹晓梅、王启江、刘海峰、张雪飞、罗万里、毛一丁、黄艳轶、卢耀柏、张华、于晓英、徐建林、薛慧林、王少恒、薛萌、吕兴军、鲁琴、徐晓光、杨涛、邓刚、王莎佟、任文峰、吕正光、许文才、曹国荣、张云、冯梦珂。本文件为首次发布。T/CPF0028—2022/T/CSTE0018—20221产品质量分级及“领跑者”评价要求激光全息定位纸1范围本文件规定了激光全息定位纸“领跑者”标准评价的评价指标体系和评价方法及等级划分。本文件适用于激光全息定位纸的产品质量分级及企业标准水平评价。相关机构在制定企业标准“领跑者”评估方案时可参照使用。企业在制定企业标准时可参照使用。2规范性引用文件下列文件中的内容通过文中的规范性引用而构成本文件必不可少的条款。其中,注日期的引用文件,仅该日期对应的版本适用于本文件;不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。GB/T7974纸﹑纸板和纸浆蓝光漫反射因数D65亮度的测定(漫射/垂直法,室外日光条件)GB/T18733防伪全息纸GB/T19001质量管理体系要求GB/T23331能源管理体系要求及使用指南GB/T23808全息防伪膜GB/T24001环境管理体系要求及使用指南GB/T45001职业健康安全管理体系要求及使用指南BB/T0087包装材料激光全息定位纸YC/T207烟用纸张中溶剂残留的测定顶空-气相色谱/质谱联用法3术语和定义GB/T18733、GB/T23808、BB/T0087界定的以及下列术语和定义适用于本文件。3.1组版缝imageassemblyseams指小版组大版时的接缝,或由不同光刻图案/元素的拼接接缝。4评价指标体系4.1基本要求4.1.1生产企业近三年,无较大及以上环境、安全、质量事故。4.1.2企业未列入国家信用信息严重失信主体相关名录。4.1.3企业可根据GB/T19001、GB/T23331、GB/T24001和GB/T45001建立并运行相应质量、能源、环境和职业健康安全管理体系,同时鼓励企业根据自身运营情况建立更高水平的相关管理体系。4.1.4产品应为量产产品,激光全息定位纸“领跑者”标准应符合GB/T18733、GB/T23808和BB/T0087规定的要求。T/CPF0028—2022/T/CSTE0018—202224.2评价指标分类4.2.1激光全息定位纸“领跑者”标准的评价指标包括基础指标、核心指标和创新性指标。4.2.2基础指标为外观、激光光刻元素质量、咬口标识、切边、尺寸偏差、水分、表面张力、定量偏差、厚度偏差、复合牢度和表层附着力。4.2.3核心指标包括偏斜度、分切标识线宽度、定位元素位置偏差和色差。4.2.4创新性指标包括组版缝、溶剂残留总量、溶剂杂质、甲醛、邻苯二甲酸酯总量、特定芳香胺总量和D65荧光亮度。4.2.5核心指标分为先进水平、平均水平和基准水平共3个等级,先进水平相当于企业标准排行榜中5星级水平;平均水平相当于企业标准排行榜中4星级水平;基准水平相当于企业标准排行榜中3星级水平。4.3评价指标体系激光全息定位纸“领跑者”标准的评价指标体系见表1。表1评价指标体系序号指标类型评价指标指标来源指标水平分级判断依据/检验方法先进水平平均水平基准水平1基础指标a外观涂层GB/T18733符合GB/T18733的要求GB/T187332图像质量3黄斑4划痕5版缝6套色错位7表面平整度BB/T0087符合BB/T0087的要求BB/T00878白点、亮点、暗点、黑斑/mm9激光光刻元素质量10咬口标识11切边12尺寸偏差/mm≤0.513水分/%GB/T18733软包:4~6卡纸:6~8GB/T1873314表面张力/(mN/m)GB/T23808水性≥38油性≥36GB/T2380815定量偏差/%BB/T0087±3.0BB/T008716厚度偏差/µm±2017复合牢度/(kN/m)≥0.1018表层附着力GB/T18733符合GB/T18733的要求GB/T1873319核心指标偏斜度/mmBB/T0087≤0.5≤1.0≤2.0BB/T008720分切标识线宽度b/mm≤0.20≤0.35≤0.5021定位元素位置偏差c/mm≤0.20≤0.35≤0.5022色差(△L*)同批同色±1.5±2.0±3.0异批同色±2.0±2.5±3.0T/CPF0028—2022/T/CSTE0018—20223表1(续)序号指标类型评价指标指标来源指标水平分级判断依据/检验方法先进水平平均水平基准水平23创新性指标组版缝/mm市场需求≤0.10≤0.20≤0.30用带刻度的放大镜,放在组版缝正上方,测量组版缝宽度24溶剂残留总量/(mg/m2)≤10≤30≤60YC/T20725溶剂杂质总量/(mg/m2)≤2≤4≤6苯系物/(mg/m2)≤0.15≤0.3≤0.5苯/(mg/m2)≤0.003≤0.004≤0.00526甲醛/(mg/kg)≤20≤30≤40附录A27邻苯二甲酸酯总量/(mg/kg)≤30≤40≤5028特定芳香胺总量/(mg/kg)≤10≤15≤2029D65荧光亮度/%≤0.7≤0.8≤1.0GB/T7974a基础指标应符合相应标准中一级品的要求。b在咬口边和与其垂直的定位边分别以阶梯状标明分切标识线。c幅面应以700mm为基准。5评价方法及等级划分评价结果划分为一级、二级和三级,各等级所对应的划分依据见表2。达到三级及以上要求的企业标准,并按照有关要求进行自我声明公开后,均可进入激光全息定位纸企业标准排行榜。达到一级要求的企业标准,且按照要求进行自我声明公开后,其标准和符合标准的产品可以直接进入激光全息定位纸的企业标准“领跑者”候选名单。表2指标评价要求及等级划分评价等级满足条件一级应同时满足基本要求基础指标要求核心指标先进水平要求创新性指标至少5项,且达到先进水平要求二级应同时满足核心指标平均水平要求创新性指标平均水平要求三级应同时满足核心指标基准水平要求—T/CPF0028—2022/T/CSTE0018—20224附录A(规范性)甲醛、邻苯二甲酸酯总量、特定芳香胺总量的测定A.1抽样与样品抽取A.1.1以同一交收批、同一类型、同一规格的卷烟条与盒包装纸为一个检查批。A.1.2从检查批中随机抽取3个包装单元(箱或托盘)。A.1.3对平张条与盒包装纸,从3个包装单元(A.1.2)中,各随机抽取一包(扎或捆),共取3包(扎或捆),从各包随机抽取20张,共取3份,作为其他检验项目样品。对卷盘盒包装纸,从3个包装单元(A.1.2)中各随机抽取一卷,共取3卷,从每卷表面第一层开始,切取20张印刷完整的包装纸,共取3份,作为其他检验项目样品。分别密封包装,避免样品污染。注:3份样品,其中一份测定用,另外两份作为备用样品。A.1.4试样包装上应至少标明以下信息:——样品名称;——相关技术指标和产品指标标称值;——生产厂家;——生产日期;——抽样日期;——抽样地点;——抽样人。A.2甲醛的测定A.2.1原理用水萃取样品中的甲醛,通过2,4-二硝基苯肼衍生形成腙后,用高效液相色谱仪/紫外检测器测定,外标法定量。A.2.2试剂A.2.2.1水,GB/T6682,一级。A.2.2.2乙腈,色谱纯。A.2.2.3磷酸,质量分数≥85%。A.2.2.42,4-二硝基苯肼,纯度≥97%。A.2.2.5衍生化试剂制备。准确称取0.01g2,4-二硝基苯肼(A.2.2.4)于100mL棕色容量瓶中,精确至0.1mg,加入5mL磷酸(A.2.2.3)后用乙腈(A.2.2.2)定容。A.2.2.6甲醛-2,4-二硝基苯腙(甲醛-DNPH),纯度≥99.9%。A.2.3标准溶液A.2.3.1混合标准储备溶液准确称取10mg的甲醛-2,4-二硝基苯腙(A.2.2.6),精确至0.1mg,用乙腈(A.2.2.2)溶解并定容于100mL容量瓶中,配制成浓度为0.1mg/mL的混合标准储备液。在(0~4)℃条件下密T/CPF0028—2022/T/CSTE0018—20225封避光贮存,有效期1个月。A.2.3.2混合标准溶液准确称取10mL混合标准储备溶液(A.2.3.1)于100mL容量瓶中,用乙腈(A.2.2.2)定容,配制成浓度为0.01mg/mL的混合标准溶液,现配