ENERGYPLUS例子的中文说明

整理文档很辛苦,赏杯茶钱您下走!

免费阅读已结束,点击下载阅读编辑剩下 ...

阅读已结束,您可以下载文档离线阅读编辑

资源描述

E+例子的中文说明输入文件!VAVSingleDuctReheat.IDF!Basicfiledescription:BasictestofaverysimpleVAVsystem.Thisfileismoreorless!identicaltotheTermReheat.idffileexceptthataVAVfanhas!replacetheconstantvolumefananddamperswithcontrolshave!beenaddedtothezoneequipmentloop.!Run:2designdays.!Building:Fictional3zonebuildingwithinterzonepartitionsconnectingallzonestogether.!Nogroundcontact(allfloorsarepartitions).Roofsexposedtooutdoorenvironment.!Notethatthisfilehasonesinglepanewindowfortestingthenewdaylightingmods.!Internal:People,equipment,andlightingallatapproximatelynormallevelsandschedules.!System:3zonevariableairvolumesystemusingasingleairloop.ControlledaboutliketheoldBLASTNWS2controlprofile.Heatingupto20Cduringoccupiedhours,15Cotherwise.!Coolingto24Cwhileoccupied,30Cotherwise.Fansandcoilsscheduledtobeunavailableduringunoccupiedhours.Coolingcoiloffallwinter.Reheatcoilonallyear.!Systemconfigurationisverybasic--airloophasafanandcoolingcoil,eachzoneleghasnothingmorethanareheatcoil.!Plant:Heatingloopservedbypurchasedheating.Coolingloopservedbytwodifferenttypesofchillersandpurchasedcooling.Prioritybasedcontrolsdeterminewhichpieceofequipmenttriestomeettheload.!SolDis=FullInteriorAndExterior,Aniso,DetailedInteriorandExteriorConvection一、模拟参数-simulationparametersVersion此处允许你输入你所使用的IDF的正确的版本号。如果输入版本号与实际使用的不同将显示出现严重错误。1.2.Building1)NorthAxis从真正的北向到建筑北向的度数2)Loadconvergence(收敛)toleranceValue缺省为0.4该值表示:在收敛达到之前负荷必须满足的值3)Temperatureconvergence(收敛)toleranceValue缺省为0.4该值表示:在收敛达到之前区域温度必须满足的值4)SolarDistribution太阳辐射通过外窗进入室内的形式三个选项:Minimalshadowing:除了门和窗外,无外部的遮阳,最小阴影的情况认为太阳的辐射全部的落到地板上并被吸收FullExterior:有外遮阳FullinteriorAndExterior:同上,但太阳辐射并不是全在地板上,还包括墙和窗户3.TimeStepinhour时间步长这一项指在模拟过程中每小时取多少步长。无HVAC的模拟有HVAC的模拟时间步长:小时内的时间步长,可根据模拟的类型和经度进行调整,无HVAC系统推荐4,HVAC系统模拟推荐64.InsideConvectionAlgorithm(算法)EenergyPlus中可供选择的内部对流模式(4种)Simple:简单自然对流,根据壁面朝向设置一个热传递系数Detailed:复杂自然对流,热传递系数与不同朝向的温度差别相关联CeillingDiffuse:混合和强迫对流模式Trombe:太阳能吸收壁面对流换热系数(内、外侧):包含若干种对流换热的模型可供选择。无特殊情况下,推荐选择Detailed5.OutsideConvectionAlgorithm同上EenergyPlus中可供选择的外部对流模式(4种)SimpleDetailed6.SkyRadianceDistribution0SkyRadiance(isotropic)各向同性1SkyRadiance(anisotropic)各向异性7.SolutionAlgorithm决定哪种的热平衡算法将被使用CTF(ConductionTransferFunctions),CTF它只考虑热量的传递而不考虑湿度在建筑结构中的储存和扩散MTF(MoistureTransferFunctions),MTF是同时考虑热质传递和在建筑结构中的蒸汽的吸收EMPD(EffectiveMoisturePenetrationDepth)EMPD是可感知表面的热量散射和内表面湿度储存的计算法则。8.ZoneVolumeCapacitancemultiplier(乘数)缺省为1在特定区域空间里的空气的容量,如果区域空气容量需要增加以保证模拟的稳定性,那么该乘数也会增加。9.Runcontrol让用户去定义将要使用哪种类型的energyplus模拟给出的计算。例如:用户也许想执行一个或是更多的sizing计算,但是不需要进行一个全年的天气文件的模拟。或是用户也许定义了所有的流量和设备sizes并且需要一个全年的天气,而不需要任何sizing计算。TheinputforRunControlallowstheusertospecifywhatkindofcalculationsagivenEnergyPlussimulationwillperform.Forinstancetheusermaywanttoperformoneormoreofthesizingcalculationsbutnotproceedtoaannualweatherfilesimulation.Ortheusermighthaveallflowratesandequipmentsizesalreadyspecifiedanddesireanannualweatherwithoutanyprecedingsizingcalculations.DoZoneSizingCalculation:ZoneSizing(seeSizing:Zoneobject)performsaspecialcalculation,usingatheoreticalidealzonalsystem,anddeterminesthezonedesignheatingandcoolingflowratesandloads,savingtheresultsinthezonesizingarrays.IfYes,ZonesizingisaccomplishedfromcorrespondingSizing:Zoneobjectsandautosizefields.DoSystemSizingCalculationSystemSizing(seeSizing:Systemobject)alsoperformsaspecialcalculationthat,tooversimplify,sumsuptheresultsofthezonesizingcalculationandsavestheresultsinthesystemsizingarraysforreportingoncomponentsizerequirements.Sizing:System+autosize+DoZoneSizingCalculationDoPlantSizingCalculationPlantSizingusestheSizing:Plantobjectfieldsanddataonthemaximumcomponentflowrates.Thedataoncomponent(suchascoil)flowratesissavedandmadeavailabletothePlantcodewhetherornotcomponentautosizingisperformedandwhetherornotzonesizingand/orsystemsizingisperformed.Sizing:Plant+autosizeRunSimulationforSizingPeriodsYesimpliesthatthesimulationwillberunonalltheincludedSizingPeriodobjects(i.e.,SizingPeriod:DesignDay,SizingPeriod:WeatherFileDays,andSizingPeriod:WeatherFileConditionType)RunSimulationforWeatherFileRunPeriodsYesimpliesthesimulationwillberunonalltheincludedRunPeriodobjects.二、Location-Climate-WeatherFileAccess描述模拟时的周边条件1.Location天气数据文件的位置,如果存在,将覆盖在IDF中的任何位置数据。因此,对于一个年度的模拟,位置不需要输入。1)LocationName2)Latitude纬度3)Longitude经度4)TimeZone时区东八区,为85)Elevation海拔2.RunPeriod周期模拟:通过使用天气文件中的气象信息进行一段时间的模拟,可以设定开始和结束的日子定义energyplus的一个模拟周期(energyplus并不假设一个全年的模拟),如果没有输入该项应该就光是一个设计天的模拟。RunPeriod是创建一个天气文件模拟的一个必不可少的基础。多个运行周期可以被输入。Energyplus以一种Energyplus特有的天气格式,接受天气文件。在这些文件的定义中,它们能够描述DaylightSavingTimeperiods和holidays。RunPeriod将允许用户不考虑天气文件中内含的DaylightSavingTimeperiods(比如:使用或是忽略)和holidays的使用。值得注意的是,天气文件同样也包括设计条件的信息、典型的和极端的区域信息以及基于空气温度计算的地面温度。1)UseWeatherFileHolidays/SpecialDays天气文件包括holiday的定义和其他类型的特殊的天。这些天的类型会导致在做该天的模拟时,使用一个相应天的schedule。输入:yes表示保留天气文件中的这些特殊的天;no表示忽略天气文件中的这些天。2)UseWeatherFileDaylightSavingPeriod天气文件中包括DaylightSavingperioddays的指示器(不是所有的天气文件中都包含这些特殊的时期)。你可以忽略这些在天气文件中的指派。3)ApplyWeekendHolidayRule在一些国家,当假日正好是在周末时,他们经常评论与该holidayday最近的一个平常天(通常说来如果该特定天在周六,那么该observedday就是周五,如果特定天在周天,那么observeday是周一)。

1 / 30
下载文档,编辑使用

©2015-2020 m.777doc.com 三七文档.

备案号:鲁ICP备2024069028号-1 客服联系 QQ:2149211541

×
保存成功