招标文件XX供电公司110kV变压器保护(主后分置)专用技术规范xxxxx电力公司20XX年X月目次110kV备用电源自动投入装置专用技术规范1标准技术参数···········································································································1192项目需求部分···········································································································1202.1货物需求及供货范围一览表·························································································1202.2必备的备品备件、专用工具和仪器仪表供货表·····································································1212.3图纸资料提交·········································································································1212.4工程概况··············································································································1212.5使用条件··············································································································1222.6项目单位技术差异表·································································································1222.7一次、二次及土建接口要求(适用扩建工程)·····································································1223投标人响应部分········································································································1223.1投标人技术偏差表····································································································1233.2销售及运行业绩表····································································································1233.3推荐的备品备件、专用工具和仪器仪表供货·······································································1233.4最终用户的使用情况证明····························································································1233.5投标人提供的试验检测报告表·······················································································1233.6投标人提供的鉴定证书表····························································································1241标准技术参数投标人应认真逐项填写标准技术参数表(见表1~表5)中投标人保证值,不能空格,也不能以“响应”两字代替,不允许改动招标人要求值。如有差异,请填写表12投标人技术偏差表。表1110kV变压器差动保护标准技术参数表序号参数名称单位标准参数值投标人保证值1*差动速断动作时间ms≤25ms(2倍整定值)(投标人填写)2*比率差动动作时间ms≤35ms(2倍整定值)(投标人填写)3*电流定值误差不超过±3%(投标人填写)4*制动系数定值误差不超过±3%(投标人填写)5交流电流回路功率损耗(每相)W≤0.5VA(IN=1A)≤1VA(IN=5A)(投标人填写)6装置直流消耗W≤50W(工作时)≤80W(动作时)(投标人填写)表2110kV变压器后备保护标准技术参数表序号参数名称单位标准参数值投标人保证值1*后备保护电流定值误差不超过±3%(投标人填写)2*后备保护电压定值误差不超过±3%(投标人填写)3*后备保护时间定值误差固有延时不应大于40ms(对于过量保护施加1.2倍动作值进行测试,欠量保护施加0.8倍动作值)(投标人填写)4*后备保护方向元件动作范围边界误差(最大灵敏角下)不超过±3°(投标人填写)5交流电压回路功率损耗(每相)W≤1VA(投标人填写)6交流电流回路功率损耗(每相)W≤0.5VA(IN=1A)≤1VA(IN=5A)(投标人填写)7装置直流消耗W≤50W(工作时)≤80W(动作时)(投标人填写)表3110kV非电量保护标准技术参数表序号参数名称单位标准参数值投标人保证值1*非电量启动功率W5W(投标人填写)2*启动电压直流操作电压的55%~70%(投标人填写)3*动作时间ms10ms~35ms(额定直流电源电压下)(投标人填写)表4打印机标准技术参数表序号参数名称单位标准参数值投标人保证值1工作电源V220VAC(投标人填写)2接口型式与保护装置配套(投标人填写)110kV备用电源自动投入装置专用技术规范表5保护柜标准技术参数表序号参数名称单位标准参数值投标人保证值1尺寸mm高度:2260mm;宽度:800mm;深度:600mm(投标人填写)2颜色GSB05-1426-200177号GY09冰灰桔纹(投标人填写)注1.项目单位对标准技术参数表中参数有差异时,可在项目需求部分的项目单位技术差异表中给出,投标人应对该差异表响应。差异表与标准技术参数表中参数不同时,以差异表给出的参数为准。2.参数名称栏中带*的参数为重要参数。如不能满足要求,将被视为实质性不符合招标文件要求。2项目需求部分2.1货物需求及供货范围一览表表6货物需求及供货范围一览表序号名称单位招标人要求投标人响应型式、规格数量型式、规格数量1变压器差动保护台2变压器后备保护台3非电量保护台4电压切换箱台5操作箱台6柜体及附件面7打印机台8其他表7可选择的技术参数表序号名称参数投标人响应备注1装置工作电源(招标人填写)2TA二次额定电流(招标人填写)如果不一致,按侧注明3差动保护制动侧数(招标人填写)4配置后备保护的侧数(招标人填写)含分支数5断路器跳闸线圈电流(招标人填写)如果不一致,按侧注明6断路器跳闸线圈数量(招标人填写)如果不一致,按侧注明7断路器合闸线圈电流(招标人填写)如果不一致,按侧注明8电阻接地的变压器保护要求(招标人填写)9屏柜颜色(招标人填写)10其他(招标人填写)2.2必备的备品备件、专用工具和仪器仪表供货表表8必备的备品备件、专用工具和仪器仪表供货表序号名称单位招标人要求投标人响应型号和规格数量型号和规格数量1234562.3图纸资料提交经确认的图纸资料应由卖方提交表9所列单位。表9卖方提交的须经确认的图纸资料及其接收单位提交图纸资料名称接收图纸单位名称、地址、邮编、电话提交份数提交时间认可图、最终图、说明书、出厂试验报告(附电子文档)(设计单位)1)技术协议签订后两周内,供货商应提供认可图纸。2)工程师在收到认可图纸后两周内,应将经确认的1份图纸寄送给供货商。3)供货商收到经确认的图纸两周内提出最终图认可图、最终图、说明书、出厂试验报告(附电子文档)(买方)2.4工程概况2.4.1项目名称:2.4.2项目单位:2.4.3工程规模:2.4.4工程地址:2.4.5交通、运输:2.4.6变压器型式及主接线:注由招标人填写,内容包括:变压器型式、主接线、系统接地方式以及各侧电源/负载性质等。110kV备用电源自动投入装置专用技术规范2.5使用条件表10使用条件表序号名称单位招标人要求值投标人保证值1电源的频率Hz50(投标人填写)2环境温度日最高温度℃45(投标人填写)日最低温度5(投标人填写)日最大温差25(投标人填写)3湿度日相对湿度平均值%≤95(投标人填写)月相对湿度平均值≤90(投标人填写)4海拔高度m≤2000(投标人填写)5耐受地震能力水平加速度g0.3g(投标人填写)垂直加速度g0.15g(投标人填写)6用途组屏/单装置(项目单位提供)(投标人填写)7安装方式集中/分散(项目单位提供)(投标人填写)注表10中“招标人要求值”为正常使用条件,超出此值时为特殊使用条件,项目单位可根据工程实际使用条件进行修改。2.6项目单位技术差异表项目单位原则上不能改动通用部分条款及专用部分固化的参数。根据工程使用条件,当污秽等级、海拔高度等与标准技术参数表有差异或对通用部分条款有差异时,应逐项在“表11项目单位技术差异表”中列出,并以差异表给出的参数为准。投标人应对表11的技术参数进行确认。表11项目单位技术差异表序号项目标准参数值项目单位要求值投标人保证值12……序号项目变更条款页码、款号原表达变更后表达12……2.7一次、二次及土建接口要求(适用扩建工程)3投标人响应部分投标人需填写专用部分的第1和第2部分的相应表格。标准技术参数表和项目单位技术差异表中要求值不同时,以项目单位技术差异表为准。投标人保证值,不能空格,也不能以“响应”两字代替,不允许改动招标人要求值。如有差异,应填写投标人技术差异表。“投标人保证值”应与型式试验报告及其他性能试验报告相符。3.1投标人技术偏差表投标人提供的产品技术规范应与本招标文件中规定的要求一致。若有偏差投标人应如实、认真地填写偏差值;若无技术偏差则视为完全满足本技术规范的要求,且在投标人技术偏差表中填写“无偏差”。表12投标人技术偏差表序号项目对应条款编号技术招标文件要求偏差备注1233.2销售及运行业绩表表13销售及运行业绩表序号产品型号运行单位投运数量投运时间联系人及电话备注3.3推荐的备品备件、专用工具和仪器仪表供货表14推荐的备品备件、专用工具和仪器仪表供货表序号名称型号和规格单位数量1234563.4最终用户的使用情况证明3.5投标人提供的试验检测报告表表15投标人提供的试验检测报告表序号产品型号名称试验报告类别和内容依据标准试验时间试验单位110kV备用电源自动投入装置专用技术规范3.6投标人提供的鉴定证书表表16投标人提供的鉴定证书表序号鉴定产品型号名称组织鉴定单位依据标准鉴定时间