武汉世纪华胜(电力)科技有限公司转载—2004高电压测试设备通用技术条件第3部分:高压开关综合测试仪GeneratechnicalspecificationsforhighvoltagetestequipmentsPart3:highvoltageswitchintegratedetector2004-03-09发布2004-06-01实施中华人民共和国国家发展和改革委员会发布武汉世纪华胜(电力)科技有限公司转载目次前言················································································································································1范围···········································································································································2规范性引用文件·······················································································································3术语和定义·······························································································································4产品分类···································································································································5功能特性···································································································································6技术要求···································································································································7试验方法···································································································································8试验规则···································································································································9标志、包装、运输、储存········································································································参考文献·········································································································································武汉世纪华胜(电力)科技有限公司转载前言本标准是根据原国家经济贸易委员会电力司《关于确认1999年度电力行业标准制、修订计划项目的通知》(电力[2000]22号)下达的《高电压测试仪器通用技术条件》标准项目的制定任务安排制定的。DL/TT846《高电压测试仪器通用技术条件》是一个系列标准,本次发布9个部分:——第1部分:高电压分压器测量系统;——第2部分:冲击电压测量系统;——第3部分:高压开关综合测试仪;——第4部分:局部放电测量仪;——第5部分:六氟化硫微量水分仪;——第6部分:六氟化硫气体检漏仪;——第7部分:绝缘油介电强度测试仪;——第8部分:有载分接开关测试仪;——第9部分:真空开关真空度测试仪。本部分是DL/TT846《高电压测试仪器通用技术条件》的第3部分。本部分由中国电力企业联合会提出。本部分由全国高压电气安全标准化技术委员会归口。本部分起草单位:武汉高压研究所、武汉市泛科变电检修设各制造有限公司、北京北大实验电子仪器厂。本部分起草人:蔡崇积、夏武炳、杨莉、王莹。本部分委托武汉高压研究所负责解释。武汉世纪华胜(电力)科技有限公司转载部分:高压开关综合测试仪1范围DL/T846的本部分规定了高压开关综合测试仪(以下简称测试仪)的功能特性、技术要求、试验方法、试验规则及标志、包装、运输与储存。本部分适用于高压开关(高压断路器)动作特性的生产制造、试验及验收等。2规范性引用文件下列文件中的条款通过DL/T846本部分的引用而成为本部分的条款。凡是注日期的引用文件,其随后所有的修改单(不包括勘误的内容)或修订版均不适用于本部分,然而,鼓励根据本部分达成协议的各方研究是否可使用这些文件的最新版本。凡是不注日期的引用文件,其最新版本适用于本部分。GB191包装储运图示标志EQVISO780:1997GB4793.1—1995测量、控制和试验室用电气设备的安全要求第1部分:通用要求IDTIEC61010-1:1990GB/T6587.1—1986电子测量仪器环境试验总纲GB/T6587.2—1986电子测量仪器温度试验GB/T6587.3—1986电子测量仪器湿度试验GB/T6587.4—1986电子测量仪器振动试验GB/T6587.5—1986电子测量仪器冲击试验GB/T6587.8—1986电子测量仪器电源频率与电压试验GB/T6593—1996电子测量仪器质量检验规则GB/T11463—1989电子测量仪器可靠性试验DL/T596—1996电力设备预防性试验规程3术语和定义下列术语和定义适用于DL/T846本部分。3.1触头开距clearancebetweenopencontacts(gap)分位置时,开关一极的各触头之间或其连接的任何导电部分之间的总间隙。武汉世纪华胜(电力)科技有限公司转载行程(触头的)travel(ofcontacts)分、合操作中,开关动触头起始位置到任一位置的距离。3.3超行程overtravel合闸操作中,开关触头接触后动触头继续运动的距离。[GB/2900.20—1994]注:对某些结构,如对接式触头,为触头接触后产生闭合力的动触头部件继续运动的距离。3.4时间行程特性time-traveldiagram合、分操作中,开关的动触头行程与时间的关系。3.5分闸速度openingspeed开关分(闸)过程中动触头的运动速度。注:实施时常以某尽量小区段的平均值表征。3.6触头刚分速度speedatinstantofcontactssepaating开关分(闸)过程中,动触头与静触头分离瞬间的运动速度。注:测试有困难时,常以刚分后l0ms内的平均值表征。3.7合闸速度closingspeed开关合(闸)过程中,动触头的运动速度。注:实施时常以某尽量小区段的平均值表征。3.8触头刚合速度speedatintantofcontctstouching开关合(闸)过程中,动触头与静触头接触瞬间的运动速度。注:测试有困难时,常以刚合前l0ms内的平均值表征。3.9武汉世纪华胜(电力)科技有限公司转载合(闸)位置(开关装置的)closedposition(ofaswitchingdevice)保证开关装置主回路的预定连续性(通电)的位置。3.10分(闸)位置(开关装置的)openposition(ofaswitchingdevice)保证开关装置主回路中分闸的触头间具有预定(电气)间隙的位置。3.11合(闸)时间closingtime从接到合(闸)指令瞬间起到所有极触头都接触瞬间的时间间隔。注1:合(闸)时间包括开关合闸所必需的并与开关组成一整体的任何辅助设各的动作时间。注2:对装有并联电阻的断路器,需把与并联电阻串联的触头都接触瞬间前的合闸时间和主触头都接触瞬间前的合(闸)时间作出区别。除非另有说明,合(闸)时间就是指直到主触头都接触瞬间的时间。3.12分-合时间(自动重合时)open-closetime(duingauto-eclosing)重合操作时,从所有极的弧触头都分离瞬间起到所有极各弧触头都重新接触瞬间的时间间隔。3.13无电流时间(自动重合时)dedtime(duringauto-eclosing)自动重合闸中,开关分操作时,从各极均熄弧起到随后重新合时任意一极首先通过电流时的时间间隔。注1,对装有并联电阻的断路器,需对下列情况作出区别即不包括从主电弧熄灭瞬间起到电阻电流电弧熄灭瞬间的时间间隔,也不包括从建立电阻电流瞬间起到建立全电流瞬间的时间间隔的无电流时间。包括上述一种或两种时间间隔的无电流时间。注2:无电流时间可以由于预击穿时间和燃弧时间的变化而不同。3.14重合闸时间reclosingtime重合闸操作中,从接到分闸指令瞬间起到所有极的动静触头都重新接触瞬间武汉世纪华胜(电力)科技有限公司转载的时间间隔。3.15合-分时间;金属短接时间close-opentime在合-分操作中,从所有极各触头都接触瞬间起到随后的分操作时在所有极中弧触头都分离瞬间的时间间隔。注:除非另有说明,即认为与开关装在一起的分闸脱扣器是在首合极中各触头都接触瞬间通电。这种情况下的分-合时间是最短的合一分时m。3.16分闸时间(开关的)openingtime(ofaswitchingdevice)从开关分闸操作起始瞬间(即接到分闸指令瞬间)起到所有极的触头分离瞬间的时间间隔。注:对装有并联电阻的断路器,需把直到弧触头都分离瞬间的分闸时间和直到带并联电阻的串联触头都分离瞬间的分闸时间作出区别。除非另有说明,分闸时间就是指直到主触头都分离瞬间的时间。3.17开关合(闸)同期性closing-simultaneityoftheswitchingdevice开关合时各极间及(或)同一极各断口间的触头接触瞬间的最大时间差异。3.18开关分(闸)同期性opening-simultaneityoftheswitchingdevice开关分时各极间及(或)同一极各断口间的触头分离瞬间的最大时间差异。3.19时间-电流特性time-currentchaacteristic在规定操作条件下,表示时间(例如动作时间)作为预期电流的函数的曲线。3.20弹跳次数springingtimes开关动触头与静触头在分(合)闸操作中,分开(合上)的次数。3.21弹跳时间springingtime武汉世纪华胜(电力)科技有限公司转载开关动触头与静触头在分(合)闸操作中,从第一次分开(合上)开始到最后稳定地分开(合上)为止的时间。3.22分(合)闸平均速度open(close)averagespeed开关分(合)闸操作中,动触头在整个运动中的行程