DSS-L软起动器用户手册安全注意事项警告!主回路电源得电后即存在危险电压。警告!电机停止后,主回路上依然存在危险电压,须在软起动器断电后,再打开前面板。警告!DSS—L软起动器停止后,继电器端子上(6、7、8、9)依然存在危险电压。警告!不允许软起动器输出端(2L1、4L2、6L3)接补偿电容器或压敏电阻。警告!电机综合保护器应接于软起动器输入端(1L1、3L2、5L3),不允许接于输出端。警告!软起动器与变频器混用时,二者输出端要彼此隔离。警告!不要试图修理损坏的器件,请与供货商联系。警告!散热器的温度可能较高(在线运行方式下)。警告!严禁在软起动输出端反送电。DSS-L软起动器用户手册1目录1.产品简介·················································12.产品型号及收货检查·································23.安装························································34.接线························································4&4.1主回路接线··········································4&4.2控制回路接线·······································4&4.3控制端子说明·······································55.显示························································7&5.1功能特点·············································7&5.2键盘说明·············································8&5.3显示状态说明·······································86.设定及操作··············································9&6.1编程操作·············································9&6.2参数设定及说明·····································97.维护······················································108.故障分析···············································119.技术参数···············································13&9.1一般参数···········································13&9.2基本接线图········································1410.不同应用的基本设置·····························15DSS-L软起动器用户手册21.产品简介及特点DSS-L系列电机软起动器是一种将电力电子技术,微处理器和自动控制相结合的新型电机起动装置。它能无阶跃地平稳起动/停止电机,避免因采用直接起动、星/三角起动、自耦减压起动等传统的起动方式起动电机而引起的机械与电气冲击等问题,并能有效地降低起动电流及配电容量,避免增容投资。DSS-L系列软起动器特点如下:①多起动方式:限流起动、斜坡起动、斜坡限流起动,最大程度满足现场需求,实现最佳起动效果。②高可靠性:有高性能微处理器对控制系统中的信号进行数字化处理,避免了以往模拟线路的过多调整,从而获得极佳的准确性和执行速度。③强大的抗干扰性:控制单元中的信号均采用光电隔离方式,并设置了不同的抗噪级别,避免了主电网上干扰引起的软起动器误动作。④简便的调整方式:控制系统应用范围广,方式调整简便、直观,通过各种功能选项可匹配各类不同的控制对象。⑤结构的优化:独特的紧凑结构设计,特别方便用户集成到已有系统中,为用户节约系统改造费用⑥电机的保护:多种电机保护功能(如过流、输入/输出缺相、晶闸管短路、过热保护等)确保电机及软起动器在故障或误操作时不被损坏。⑦维护简便:由4位数码显示组成的监控信号编码系统,24小时监控系统设备的工作状况,同时提供快速故障诊断。DSS-L软起动器用户手册32.产品型号及收货检查设备拆封后请按下列步骤仔细检查,如发现问题,请及时与供货商联系。&2.1铭牌检查请检查您收到的产品规格型号与您所订购的是否相符。DSS-□□□□—□适用电压等级:3-380V,6-660V适配电机功率:例如045表示45KW系列号:P-普通型,S-智能型,L-数码型产品代码&2.2产品检查请检查产品在运输过程中是否有损伤,如:外壳凹陷、变形,连线、连接件松动等。&2.3装箱检查每台软起动器配有产品合格证、保修卡、《使用说明书》各一份,检查是否齐全。DSS系列软启动器型号规格:DSS—输入电压:VAC适配电机:KW出厂编号:XNR出厂日期:年月日沈阳西诺尔电气有限公司沈阳西诺尔电气有限公司DSS-L软起动器用户手册43.安装为保证良好的产品性能,软起动器必须垂直安装。安装空隙应遵循下表。安装环境通风良好,室内安装,避免阳光直射。环境温度:-25℃~+45℃相对湿度:≤95%(20℃±5℃)环境条件:无易燃、易爆、腐蚀性气体,无导电尘埃室内安装,通风良好振动小于0.5G海拔超过2Km,应相应降低容量使用外型尺寸及开孔图(单位:mm)规格型号GHIKLMABCDSS-L008~075170286200133250751020DSS-L090~160286439220240357951020DSS-L185~315325480220279386951020DSS-L400~53040762022035148195102090KW及以上产品75KW及以下产品DSS-L软起动器用户手册54.接线&4.1主回路端子1L1、3L2、5L3接电源端,2T1、4T2、6T3接电机端。相序对软起动器没有影响。交流接触器的安装参见右图。&4.2控制回路注意:3、4、5节点接法只是开关信号的闭合或断开,无需接电源K1K2控制电源端子外控信号端子电流信号端子故障220VAC50/60HzSILimCommonRunStop旁路接线图-B接线图-ADSS-L软起动器用户手册6&4.3端子说明端子序号端子名称说明技术参数输入端子1电流取样端子接电流互感器,接时无方向见附件选用23外控信号公共端子外控时分别与起动、停止端子短接4外控起动信号端子起动、停止控制电路有单节点和双节点两种接线方式。如图(A)单节点如图(B)双节点5外控停止信号端子11控制电源输入端端子11接电源L端子12接零N220V±15%50Hz12输出端子6起动完成信号输出端子用于K2闭合后控制旁路接触器接点容量:AC250V/5A78故障输出端子故障时K1闭合输出信号报警接点容量:AC250V/5A910接地端子®接软起动器外壳1.5-2.5mm²®!接地电缆应尽可能短,并接于起动器旁最近的接地点。合适的地点应位于安装板上紧靠软起动器处。安装板也应接地。这是安全接地,而不是保护接地。回路说明:旁路接触器和电流互感器都是软起动器选件(需另行订购),在用户不选用互感器时,软起只能以斜坡方式起动工作,运行时无过流保护。注意:在选用互感器变比时务必按下表执行!附件选用:DSS-L软起动器用户手册7适配电机(KW)规格型号额定电流(A)接触器型号(选件)外部电流互感器(选件)7.5DSS-L008-318CJX4-2550:511DSS-L011-324CJX4-3250:515DSS-L015-330CJX4-32100:518.5DSS-L018-339CJX4-40100:522DSS-L022-345CJX4-50100:530DSS-L030-360CJX4-63100:537DSS-L037-376CJX4-80200:545DSS-L045-390CJX4-95200:555DSS-L055-3110CJX4-115F300:575DSS-L075-3150CJX4-150F300:590DSS-L090-3180CJX4-185F400:5110DSS-L110-3218CJX4-225F500:5132DSS-L132-3260CJX4-265F500:5160DSS-L160-3320CJX4-330F600:5185DSS-L185-3370CJX4-400F600:5220DSS-L220-3440CJX4-500F800:5250DSS-L250-3500CJX4-500F1000:5280DSS-L280-3560CJX4-630F1000:5315DSS-L315-3630CJX4-630F1500:5400DSS-L400-3780JWCJ20-800A1500:5470DSS-L470-3920JWCJ20-1000A1500:5530DSS-L530-31000JWCJ20-1000A1500:5DSS-L软起动器用户手册85.显示该起动器采用数码显示式操作键盘,可实现参数设定、显示、修改以及故障显示、复位和起动、停机等控制。&5.1功能特点:可调参数:起始电压(PO)起动时间(P1)停车时间(P2)起动电流(P3)起动方式:斜坡限流软起动电压斜坡软起动电流限幅软起动停车方式:电压斜坡停车方式自由停车方式软起/软停电压(电流)特性曲线DSS-L软起动器用户手册9&5.2键盘说明:确认键:1、进入参数菜单增减键:1、选择参数项2、确认要修改的参数2、修改参数值退出键:1、退出参数菜单停止键:1、停止设备运行2、退出参数项2、故障复位运行键:起动设备&5.3显示状态说明:序号显示符号状态说明备注1停止状态设备处于停止状态2编程状态此时可阅览和设定参数3运行状态1设备处于软起动过程状态4运行状态2设备处于全压工作状态5运行状态3设备处于软停车状态6故障状态设备处于故障状态DSS-L软起动器用户手册106.编程及操作说明&6.1编程操作当软起动器通电后,即进入起动准备状态,键盘显示STOP,此时按—键进入编程状态。编程状态下软起动可进行以下两种操作:参数阅览和参数设定,当显示参数前两位处于闪烁状态时是参数阅览状态,后两位处于闪烁状态时是参数设定状态。参数阅览状态时,按∧或∨键进行参数阅览;按—键进入参数设定状态,按∧或∨键进行参数设定及修改。按C键退出本级菜单并返回上一级。&6.2参数设定及说明参数显示有四位,前两位是参数项,后两位是参数值。序号显示参数说明操作说明出厂值1起始电压(10%-70%)Ue16级可调设为99%时为全压起动★参数设定状态下,按∧或∨键可修改起动电压大小。20%2起动时间0~60秒16级可调选择0秒为电流限幅软起动★参数设定状态下,按∧或∨键可修改起动时间。103停车时间0~60秒16级可调选择0秒为自由停车★参数设定状态下,按∧或∨键可修改停车时间。0DSS-L软起动器用户手册114电流限幅倍数(2~5)Ie16级可调★参数设定状态下,按∧或∨键修改起动电流限幅倍数。35运行过流保护(1.5~5)Ie8级可调★参数设定状态下,按∧或∨键修改运行过流保护值。1.56未定义参数7控制选择0—接线端子控制1—操作键盘控制2—键盘、端子同时控制★参数设定状态下,按∧或∨键选择控制方式。28SCR保护选择0—允许SCR保护1—禁止SCR保护★参数设定状态下,按∧或∨键选择是否用可控硅保护。09未定义参数设置参数须在软起动器的非工作状态下进行!软起动器所有技术参数在环境温度低于45℃时有效,对高于45℃至60℃的环境温度,额定功率需