1目录1.编制依据·····························22.工程概况·····························23.施工准备·····························33.1施工现场准备··························33.2施工流水段划分原则·······················43.3施工流程····························44.技术准备·····························45.材料准备·····························45.1钢筋原材····························45.2模板架料····························65.3混凝土·····························66.机具准备和劳动力安排·······················76.1机具准备(人防部分)······················76.2劳动力安排(人防部分)·····················77.主要的施工方法和技术措施·····················87.1钢筋工程····························87.2模板工程····························247.3混凝土工程···························338.质量保证措施···························458.1钢筋工程质量控制························458.2模板工程质量控制························468.3混凝土施工质量控制措施·····················479.成品保护措施···························4810.基坑降水边坡维护··························································································48211.安全生产与文明施工措施······················511.编制依据施工合同文本《混凝土结构施工图平面整体表示方法制图规则和构造详图筏形基础》11G101-3《混凝土结构施工图平面整体表示方法制图规则和构造详图》11G101-1《建筑设计防火规范》GB50016-2006《高层民用建筑设计防火规范》GB50045-95(2005版)《汽车库、修车库、停车场设计防火规范》GB50067-97《汽车库建筑设计规范》JGJ100-98《建筑内部装修设计防火规范》GB50222-95《建筑灭火器配置设计规范》GB50140-2005《人民防空地下室设计规范》GB50038-2005《人民防空工程设计防火规范》GB50098-98《建筑地基基础工程施工质量验收规范》GB50202-2002《混凝土结构工程施工及验收规范》GB50204-2002《建筑工程抗震设防分类标准》GB50223-2004《普通混凝土配合比设计规程》JGJ55-2000《钢筋机械连接通用技术规程》JGJ107-2010《地下工程防水设计规范》GB50108-2008《防空地下室结构设计》07FG01~05《防空地下室建筑设计》FJ01~04《人民防空地下室设计规范》GB50038-2005共信华侨城二期人防工程结构和建筑图纸。2.工程概况本工程位于鞍山市铁西区六道街与九道街之间,原鞍山市广播电视大学校址,总建筑面积8845.5平方米,人防建筑面积7859.11平米。地下人防工程主要位于本工程部分楼旁及相邻地下车库。人防工程防水为一级,耐火等级:一级,抗震设防烈度:7度,使用年限为:50年。3本工程设计为4个防护单元:第一防护单元2294.44m2、二等人员掩蔽所、掩蔽面积1994.44m2、掩蔽人数1195人、疏散宽度4.3米、防护等级:甲类6级,防化等级丙级、抗暴单元数量4个。第二防护单元1382.20m2、二等人员掩蔽所、掩蔽面积1182m2、掩蔽人数1182人、疏散宽度4.5米、防护等级:甲类6级,防化等级丙级、抗暴单元数量4个。第三防护单元1971.82m2、二等人员掩蔽所、掩蔽面积1771.82m2、掩蔽人数1062人、疏散宽度4.5米、防护等级:甲类6级,防化等级丙级、抗暴单元数量4个。第四防护单元2283.50m2、二等人员掩蔽所、掩蔽面积1983.50m2、掩蔽人数1134人、疏散宽度2.8米、防护等级:甲类6级,防化等级丙级、抗暴单元数量4个。防核武器等级:核6级,防常规武器等级:常6级。序号项目内容1工程名称共信华侨城地下人防工程2工程地址鞍山市铁西区六道街与九道街之间,原鞍山市广播电视大学校址3建设单位鞍山共信房地产开发有限责任公司4设计单位辽宁省人防建筑设计研究院5监理公司鞍山市纵横工程监理咨询有限公司6质量监督鞍山市住房和城乡建设委员会建筑工程质量监督站7施工总包鞍山市东大建筑工程有限公司9合同范围土建、装饰、给排水、采暖、电气及消火栓等工程10投资性质自筹11合同工期14个月12合同质量目标合格3.施工准备3.1施工现场准备根据现场的实际情况,便于材料的加工和运输,在施工现场内部建钢筋加工区和钢筋堆放场地及模板加工场。43.2施工流水段划分原则地库底板及筏板流水段划分时根据图纸后浇带进行划分,以减少板施工缝隙,规避防水风险为原则。以工程量大致相同、平衡人、机、料的投入量和配置,合理安排施工场地为原则。3.3施工流程基坑降排水→土方开挖、支撑施工→截桩、凿桩→垫层砼浇注→桩头防水处理、底板防水卷材施工→底板钢筋放线→底板钢筋绑扎→底板砼浇注→底板砼养护→测量放线→地下墙、柱、梁、板钢筋绑扎→地下墙、柱、梁、板支模→地下墙、柱、梁、板砼浇注→地下墙、柱、梁、板砼养护4.技术准备4.1组织施工技术人员熟悉图纸,了解设计意图。4.2施工方案及交底的编制。项目技术部编制详细的施工方案并进行方案交底,明确施工中应注意的事项。4.3施工技术交底。责任工程师对操作班组进行交底,明确操作中的技术要求和质量控制标准和措施。5.材料准备5.1钢筋原材5.1.1钢筋原材质量控制图质量员材料员甲方和监理项目物资部材料工程师填写试验委托单试验员按规定现场随机取样、复试填写材料报验单报监理公司投入使用项目物资部各种资料技术部存档责任工程师技术部责任师钢筋进场计划单结构分包审核材料员物资公司收集资料验收批量55.1.2钢筋的检验要求(1)材质要求根据施工进度计划,钢筋进场按钢筋备料单分批进场,同时钢筋进场时必须具有出厂质量证明书或试验报告单。每批钢筋进场必须按规格附带该批钢筋的试验报告单,且试验报告单上的代表数量不应小于所进场的数量,试验报告单必须是原件,不得使用复印件。(2)复试要求钢筋出厂时,在每捆(盘)上都挂有标牌,印有厂标、钢号、炉(批)号、直径等标号。钢筋进入施工现场时应分批进行验收。(3)外观检查钢筋表面不得有裂缝、结疤、折叠及锈蚀。(4)力学性能试验同一种规格每批重量不大于60t,在每批钢筋中的任意两根钢筋上各取一套,每套试样从每根钢筋端部截去50cm,然后再截取两根,一根做拉伸试验(包括屈服点、抗拉强度和延伸率),另一根做冷弯试验(监理到场见证取样)。试验时,如有一个试验结果不符合规范所规定的数值时,则应另取双倍的试样,对不合格的项目做第二次试验,如仍有一根试样不合格,则该批钢筋为不合格品不予验收。5.1.3钢筋堆放要求堆放钢筋的场地要坚实平整,在场地基层上浇筑100厚的C20混凝土,并从中间向两边设排水坡度,避免基层出现积水。堆放时钢筋下面要垫垫木,垫木厚度不应小于20cm,间距1500mm,以防止钢筋锈蚀和污染。(1)原材堆放钢筋原材进入现场后,按照现场施工平面布置的位置分规格进行堆放,不能为了卸料方便而随意乱放。(2)成品钢筋堆放将加工成型的钢筋分层、分段、分部和构件名称按号码顺序堆放,同一部位钢筋或同一构件要堆放在一起,保证施工方便。(3)钢筋的标识6钢筋原材及成品钢筋堆放场地必须设有明显标识牌,钢筋原材标识牌上应注明钢筋进场时间、受检状态、钢筋规格、长度、产地等;成品钢筋标识牌上应注明使用部位、钢筋规格、钢筋简图、加工制作人及受检状态。5.2模板架料本工程的模板架料统一进行租赁或采购,模板支撑体系详见《地下结构模板施工方案》。5.3混凝土5.3.1混凝土配合比及材料要求(1)搅拌站按照设计要求的混凝土强度等级对其所选用的水泥品种、砂石级配、含泥量和外加剂等进行混凝土试配,得出优化配合比,并把试配结果及相关材质报告报送到项目经理部,由技术负责人审核,报监理审查认可。(2)在混凝土中掺加的混凝土外加剂的性能或种类,必须符合设计要求及规定批准使用的品种和生产厂家,并报监理认可后方准使用。1)普通混凝土:选用普通硅酸盐水泥,低水化热。选用中砂,含泥量应在2%之内,泥块含量不大于1%。洗净的卵碎石,最大粒径25mm,含泥量不大于1%,泥块含量不大于0.5%。搅拌用水要求清洁、可饮用、无色无味。减水缓凝剂:缓凝6小时以上(根据天气情况及施工可适当调整)。为了有效预防混凝土碱骨料反应发生所造成的危害,对于掺入混凝土的外加剂的碱含量(Na2O+0.658K2O)加以规定,由化学外加剂带入混凝土工程中的碱含量防水类应≤0.7kg,非防水类≤1.0kg。混凝土中最大碱含量3.0kg/m3。2)抗渗混凝土:粗骨料宜采用连续级配,最大粒径不宜大于40mm,含泥量不得大于1.0%,泥块含量不得大于0.5%。细骨料最大粒径不宜大于40mm,含泥量不得大于1.0%,泥块含量不得大于0.5%。每立方米混凝土中的水泥和矿物掺和料总量不宜小于320kg。砂率为35%~45%。需进行抗渗性能试验。5.3.2砼的供应本工程混凝土全部采用商品混凝土,选用多家技术实力强、生产能力足、社会信誉好的砼厂家作为本工程的供应商。混凝土坍落度由搅拌站根据季节、气温、运输路径等条件试配确定,泵送砼坍落度控制在18±2cm;混凝土泵车或塔吊吊斗下灰时,坍落度不大于18cm,水灰比不宜大于0.5,初7凝时间控制在7-11小时。对防水砼和普通砼不同强度等级、不同品种的砼同时使用时,应专车专供,并在罐车前挡风玻璃上贴上标识,以防出现差错。6.机具准备和劳动力安排6.1机具准备(人防部分)序号机具名称单位数量用途1钢筋切断机台2钢筋切断2砂轮切割机台4钢筋切割3钢筋成型机台2钢筋成型4钢筋调直机台2钢筋调直5直螺纹套丝机套2钢筋连接6电焊机台6钢筋连接及机电7断绑扎丝铡刀台2断绑扎丝8塔吊台49布料杆台410混凝土地泵台111汽车泵台212砼振动棒只613圆锯台314平压两用刨台115手电钻台416手提电箱台817手电锯台106.2劳动力安排(人防部分)序号工种数量(人)备注1钢筋工60钢筋绑扎2模板工80模板支设83测量人员4测量4砼工30浇注混凝土5力工40搬运6瓦工20混凝土面抹平收光7架子工15外脚手架搭设7.主要的施工方法和技术措施7.1钢筋工程7.1.1钢筋加工(1)钢筋放样钢筋加工前,由技术人员依据结构施工图、规范要求、施工方案及有关洽商对各种构件的每种规格钢筋放样并填写《钢筋配料单》。《钢筋配料单》应注明钢筋的规格、形状、长度、数量、应用部位等。《钢筋配料单》经项目专业责任师审核签字认可后,开始加工。(2)钢筋下料1)直筋下料长度=构件长度-保护层厚度+弯钩增加长度+接头连接长度-弯钩弯曲调整值。2)弯起筋下料长度=直段长度+弯起段长度+斜段长度-弯曲调整值+弯钩增加长度+接头连接长度3)箍筋下料长度=箍筋周长+箍筋调整值+2弯钩长度。4)钢筋弯钩增加长度。半圆弯钩增加长度6.25d,直弯钩3.5d,斜弯钩4.9d。箍筋调整值+两个弯钩增加长度(mm)。(3)钢筋弯曲1)应按:划线→试弯→弯曲成型的顺序进行