AMFX-Manual-V240

整理文档很辛苦,赏杯茶钱您下走!

免费阅读已结束,点击下载阅读编辑剩下 ...

阅读已结束,您可以下载文档离线阅读编辑

资源描述

1/12001/10/09AutoMountFeedbackforX-series(Program-AMFX_10*.pgm,Manual-Ver2.40E)YAMAHAMOTORCO.,LTD.IMCAMPANYENG.TEAM.MOUNTERGr.2/2ContentsOverview________________________________________________________4ExecutionConditions____________________________________________5MountingAdjustmentProcedure___________________________________61.CameraAdjustment________________________________________62.RAxisAccuracy__________________________________________73.WarmUp__________________________________________________74.AdjustmentStepsfortheVariousRec.Devices____________7Proceduresforexecutingthevariousadjustmentsteps____________91.PreliminaryPreparation_________________________________10SelectingtheRecognitionMethod___________________10SpecifyingUsingRecognitionCamera________________10HeadSettingsForQFPNozzles______________________10ConfirmationaboutCord-MACSandMulti-MACS________112.Select/ConfirmPCBData_________________________________113.WarmUp_________________________________________________114.Mount___________________________________________________115.ConfirmMarkDatabase___________________________________126.AMFProgram_____________________________________________127.SelectPCBData(CameraNo.)____________________________128.ComponentRecognition___________________________________129.CheckTheResult________________________________________1310.CheckTheCorrectedValues_____________________________1411.SaveTheMeasuredData_________________________________1412.SaveTheAdjustmentsLog_______________________________1413.RestoringTheVariousSettings_________________________14AMFPCBData___________________________________________________151.PCBInformation_________________________________________152.MountInformation_______________________________________153.ComponentInformation___________________________________154.MarkInformation________________________________________175.BlockRepeatInformation________________________________176.Localfiducialinformation______________________________177.Localbadmarkinformation______________________________17AdjustedParameter_____________________________________________181.Movingcameraposition__________________________________182.Multicameraposition___________________________________183/33.Singlecameraposition__________________________________184.Headoffset_____________________________________________185.Zigzagparameter________________________________________186.Paralellparameter______________________________________187.Rotationparameter______________________________________18ItemstobeAdjustedonVariousModels_________________________191.YV100X-F,[TOPAZ-X]______________________________________192.YV100X-S________________________________________________203.YV88X-F_________________________________________________214.YV88X-SF,[EMERALD-X]____________________________________225.HSDX____________________________________________________236.YV100XT-F,[OPAL-X],YV100XTL-F__________________________247.YV100XT-S,YV100XTL-S___________________________________258.YV180X__________________________________________________269.i-CUBE,4HEADS___________________________________________2710.i-CUBE,SSF+SSFHEADs,SSF+SFHEADs,SF+SFHEADs________28ExecutingtheAMFProgram______________________________________291.BootingtheAMFProgram_________________________________292.SelectingthePCBNameandRecognitionDevice___________293.BeginningtheMeasurement_______________________________304.EndingtheMeasurement__________________________________305.SelectingtheDisplay___________________________________30[1/Yes,IwanttoFEEDBACK.]_______________________30[2/No,IdoNOTwanttoFEEDBACK.]_________________31[3/ShowDetailsofResults.]_______________________31[4/ShowallofmeasuredData.]_____________________31[5/Showfeedbackvalue.]___________________________326.ExitingtheAMFProgram_________________________________32Howtouse“AMFCHART”_______________________________________331.ExecuteAMFCHARTmacro_________________________________332.Selectdata_____________________________________________333.Chartoption____________________________________________334.Makechart______________________________________________344/4OverviewTheAutoMountFeedback(AMF)isanautomaticmountingprecisionadjustmentprogramdesignedforusewithYAMAHAFullVisionSurfaceMountersandDispensers.Intheautomaticoperationmode,somemountedchipcomponentsordummycomponentslikeaglassQFPordispensedfluidarerecognizedbythemarkrecognitioncameraplacedontheheadunit,andthemountingprecisionismeasured.Theparametersusedformountingarethenautomaticallycorrectedbythemachine.FeaturesoftheNewAMF1.VariousnewtypesofparametersaresupportedbyVIOSsoftwareVer.2.0std.orlater.2.PCBdatausedformountingcanbeedited,andcanbeadjustedtofitthepurposeathand.3.Themeasuredmountingprecisiondatacanbeoutputasatext-formatfile.Thesefilescanthenbeusedinspreadsheetprograms,foreasyconstructionofgraphsandcalculationofstatisticaldata.4.Theamountbywhichmachinedatahasbeencorrectedcanbeconfirmed,ascantheadjustmentresults.5.Datacanbeconfirmedonthespot,categorizedbycamera,byhead

1 / 34
下载文档,编辑使用

©2015-2020 m.777doc.com 三七文档.

备案号:鲁ICP备2024069028号-1 客服联系 QQ:2149211541

×
保存成功