药厂净化中央空调工程设计(空调负荷计算表)

整理文档很辛苦,赏杯茶钱您下走!

免费阅读已结束,点击下载阅读编辑剩下 ...

阅读已结束,您可以下载文档离线阅读编辑

资源描述

0备注空调工程P46空调工程P46空调工程P62空调工程P571内包装间(10K)63.82.616624±160±553.1711.3744.7541.1888.38211.116.3011000.82内包材中转间31.862.68324±160±553.1711.3744.7541.1888.38210.68.06500.43工具清洗及存放间10.712.62824±160±553.1711.3744.7541.1888.38210.23.261190.2编号建筑照明负荷kw室内温度要求oC容积m3送风点焓值kJ/kg夏季室外鲜风含湿量g/kg夏季室外鲜风焓值kJ/kg车间名称面积m2室内湿度要求%层高m外墙及吊顶面积m2围护结构(外墙)负荷kw室内空气焓值kJ/kg室内空气含湿量g/kg外墙边长m机械露点焓值kJ/kg送风量m3/h换气次数送风量m3/h换气次数空调工程P58空调工程P60空调工程P63空调工程P63空调工程P866.60.41.10.00050.81.16500397964147250202.40.10.50.00000.00.06500134842071250200.00.00.20.00000.00.065000123469625020设备负荷kw人员负荷kw围护结构(外窗)负荷kw外窗/安全门面积m2污染源面积m2室内正压值Pa除尘量风量m3/h人员数量围护结构负荷kw设备功率kw人员散湿量kg/h热湿比室内冷负荷(未考虑再热和新风)kw按温度要求确定按净化要求确定排气量m3/h空调工程P753497.64670.43200172.79670.4374147.003248.51334.80086.29334.8042070.90383.54112.54029.01112.541696.15满足卫生要求的新风量m3/h风量确定m3/h维持正压所需换气次数排气量+正压风量+漏风量m3/h维持正压风量m3/h漏风量m3/h新风量实选m3/h新风负荷kw0备注空调工程P46空调工程P46冬季室外鲜风含湿量g/kg外墙边长m层高m编号室内温度要求oC容积m3面积m2车间名称送风点焓值(30℃)kJ/kg室内湿度要求%室内空气焓值kJ/kg冬季室外鲜风焓值kJ/kg室内空气含湿量g/kgK点焓值kJ/kg送风点含湿量g/kg混合点的焓值kJ/kgK点的含湿量g/kg混合点的含湿量g/kg送风量m3/h换气次数送风量m3/h换气次数空调工程P57空调工程P58负荷计算文件中的《渗透风量计算》参照空调工程P75空调工程P63空调工程P86渗透风量m3/h室内正压值Pa排气量m3/h人员数量围护结构(外墙)负荷kw围护结构(外窗)负荷kw外墙及吊顶面积m2外窗/安全门面积m2按净化要求确定热湿比人员散湿量kg/h渗透热负荷kw围护结构负荷kw按温度要求确定维持正压所需换气次数漏风量m3/h新风量实选m3/h满足卫生要求的新风量m3/h排气量+正压风量+漏风量m3/h维持正压风量m3/h编号面积m2车间名称所需冷量kw估算室内总负荷(含再热量)kw室内总冷负荷kw估算室内总负荷(含再热量)kw所需冷量kw所需冷量(考虑同时使用率)kw室内总热负荷kw编号车间名称面积m2室内总冷负荷kw估算室内总热负荷kw所需热量kw所需热量(考虑同时使用率)kw制冷机组形式制冷机组长*宽*高mm*mm*mm蒸发器水流量(冷冻水)m^3/h过渡性季节输入功率kw夏季输入功率kw制热量kw蒸发器水压降kPa冷凝器空气流量m^3/h蒸发器水流量(热水)m^3/h制冷量kw冬季输入功率kw制冷机组型号冬季额定电流A机组运行重量kg蒸发器接管管径mm最大启动电流A风机功率kw过渡性季节额定电流A夏季额定电流A编号面积m2车间名称洁净风柜型号机组功率KW实选机组风量m3/h实选机外余压Pa供回水管的长度水的流速管件局部阻力系数水管管径空调组表冷器阻力编号面积m2车间名称制冷机组蒸发器压力降水流量房间名称新风量GX新风量GX排风量Gp排风量Gp维持正压风量Gz维持正压风量Gz选型后选型后选型后(m3/h)(m3/h)(m3/h)内包装间9796414725670.43570.7000497.64422.99内包材中转间3484207125334.80285.0000248.51211.23工具清洗及存放间123469625112.5595.800083.5471.01工具存放间167494625152.98130.2200113.5596.52工具清洗间2564146825237.38202.0700176.20149.77烘干整理间238699125128.45109.380087.1774.09男二更及洗手缓冲间125567925968.06823.04887753.9540.7234.61女二更及洗手缓冲间1635774251110.69944.311018865.346.4139.45安全门过道4354296425301.34256.7400177.84151.16制浆间3072333525728.44619.32678576.320.0917.08称配间15775532556.1747.860033.1528.18粉碎过筛间97234708251517.711290.3614121200.242.4736.10贮料间2635137625139.90119.190082.5670.18混合制粒间310743179925287.71245.1800158.27134.53烘干间135984355252394.702036.3718301555.5383.24325.75总混整粒间156611371725481.93410.3900327.07278.01颗粒中转间5225254725330.22281.2000224.11190.49装袋间(1)90683021251803.091533.2314961271.6181.23154.05装袋间(2)77963023251429.351215.561122953.7181.39154.18汇总127723616713185.8911215.9484437176.553105.162639.39按净化要求确定送风量m3/h(m3/h)(m3/h)(m3/h)换气次数换气次数送风量m3/h夏季送回风量计算具体见下表:按温度要求确定漏风量Gl漏风量G2系统送风量Gx回风量Gh实际送风量Gs回风量送风量配比率选型后空调机选型后空调机选型后风口选型后(m3/h)(m3/h)(m3/h)(m3/h)172.79147.714319.793649.363692.743122.04480076.9386.2973.762157.191822.391844.061559.06240076.8429.0124.80725.16612.61619.89524.0972086.1039.4333.70985.70832.72842.62712.40100084.2661.1852.301529.531292.151307.511105.44180072.6441.2835.281031.88903.43882.09772.71100088.2140.3434.481008.3940.33862.0138.97116074.3146.2839.561156.9746.28989.0344.72150065.94123.50105.573087.502786.162639.332382.59320082.4830.3525.95758.7930.35648.6429.3280081.0823.0219.68575.52519.35491.98444.1280061.5063.2454.061580.9563.241351.4661.10160084.4757.3449.011433.391293.491225.321106.13150081.69129.44110.653236.092948.382766.352521.17320086.45181.46155.124536.462141.763877.961841.59480080.79154.86132.383871.563389.633309.582899.19480068.95106.1190.712652.812322.592267.741986.54320070.87125.86107.593146.411343.322689.681156.45360074.71125.96107.683149.111719.762692.001476.44360074.781637.731400.0040943.1827757.3135000.0023784.0545480%(m3/h)夏季送回风量计算具体见下表:(m3/h)(m3/h)其中:①局部排风房间(烘干整理,制浆间,粉碎过筛间,总混整粒间,袋装(1),袋装(2))F——罩口面积,(m2);vX——控制点吸入风速,m/s;n——排风罩的个数,(个);式中:0.75——为尽量减少排风量,罩口四周增设法兰可使排风量减少25%G1=n3600*vX*F*0.75(m3/h)

1 / 17
下载文档,编辑使用

©2015-2020 m.777doc.com 三七文档.

备案号:鲁ICP备2024069028号-1 客服联系 QQ:2149211541

×
保存成功