空调计算040401

整理文档很辛苦,赏杯茶钱您下走!

免费阅读已结束,点击下载阅读编辑剩下 ...

阅读已结束,您可以下载文档离线阅读编辑

资源描述

工程名稱:顶正(天津)工程建築名稱:车间二1.空氣狀態乾球溫度(℃)濕球溫度(℃)露點溫度(℃)相對溼度(%)絕對溼度g/kg比容(m3/kgair)焓值(kJ/kgAir)外氣條件(夏)31.426.424.867.919.90.87382.7外氣條件(冬)-11620.910.746-8.81供风点条件1715.715.596.911.60.82446.4混风点條件29.223.921.964.615.60.86271.8室內要求條件2619.516.35511.60.85355.7冬天室內條件211612.9609.30.83844.82.無塵室狀態印刷车间小计潔淨等級100,000樓板面積(m2)29442944高度(m)7外牆面積(m2)33923.外氣處理正壓換氣(次/hr)1000機台排氣(cmm)2113外氣需求(cmm)2456.470002456.47顯熱(kw)681.400000潛熱(kw)973.110000冷卻量(kw)1654.51000冷卻量(USRT)470.45000OverCool(kw)00004.循環風量潔淨循環(次/hr)10循環風量(cmm)3434.675.室內發熱(1)熱貫流率(w/m2℃)1.89外牆傳導(kw)34.62(2)照明電力(w/m2)20照明負荷(kw)58.8858.88(3)工作人員(人)58.8800058.88發熱量(w/人)88發熱量(w/人)潜147人員負荷(kw)显5.18人員負荷(kw)潜8.66人員負荷(kw)总13.8413.84(4)設備(kw)740.4740.40(5)FCU(台數)XFCU負荷(kw)00.00總和(kw)839.1000CMM46156.循環冷卻冷卻量(kw)2493.590.000.000.002493.59冷卻量(USRT)709.03000進風溫度(℃)出風溫度(℃)冰水溫差(℃)5555冰水流量(lpm)7148.290007.冰水機總冷卻量(kw)2394.910002394.91總冷卻量(USRT)680.97000冰水溫差(℃)5666冰水流量(m3/hr)411.92000Header管徑(mm)269.90000制程用冷却水(T/H)46.3646.36制程用冷冻水(T/H)155.4155.4加热量(KW)2490.222490.22加湿量(Kg/hr)1657.621657.62加热用蒸汽量加湿用蒸汽量5023.098.冷卻水塔10.凝結水量印刷方案2019/11/23/0:07總冷卻量(kw)3897.71水量(lpm)12.10總冷卻量(USRT)1108.28水量(m3/hr)0.73冷卻水溫差(℃)5冷卻水量(m3/hr)670.41Header管徑(mm)344.32制程用蒸汽KG)供热用蒸汽KG)制冷单位负荷(W/M2)813.49供热单位负荷(W/M2)845.8612.蒸汽用量印刷方案2019/11/23/0:07工程名稱:顶正(天津)工程建築名稱:车间二1.空氣狀態乾球溫度(℃)濕球溫度(℃)露點溫度(℃)相對溼度(%)外氣條件(夏)31.426.424.867.9外氣條件(冬)-1162供风点条件1312.512.194.3混风点條件----室內要求條件2315.712.155冬天室內條件211612.9602.無塵室狀態瓶标车间潔淨等級樓板面積(m2)0360高度(m)07外牆面積(m2)06333.外氣處理正壓換氣(次/hr)100機台排氣(cmm)0外氣需求(cmm)0.0015.0700顯熱(kw)0.005.34潛熱(kw)0.007.98冷卻量(kw)0.0013.32冷卻量(USRT)0.003.79OverCool(kw)4.循環風量潔淨循環(次/hr)10循環風量(cmm)0.0005.室內發熱(1)熱貫流率(w/m2℃)1.891.89外牆傳導(kw)0.0010.0(2)照明電力(w/m2)2020照明負荷(kw)0.007.20(3)工作人員(人)0.0018.0000發熱量(w/人)8897發熱量(w/人)潜147138人員負荷(kw)显0.001.75人員負荷(kw)潜0.002.48人員負荷(kw)总0.004.23(4)設備(kw)08.4(5)FCU(台數)FCU負荷(kw)00總和(kw)0.027.4000CMM01516.循環冷卻冷卻量(kw)0.0040.720.000.00冷卻量(USRT)0.0011.5800進風溫度(℃)出風溫度(℃)冰水溫差(℃)55.0055冰水流量(lpm)0.00116.73007.冰水機總冷卻量(kw)0.0043.2000總冷卻量(USRT)0.0012.2800冰水溫差(℃)56.0066冰水流量(m3/hr)0.006.1900Header管徑(mm)0.0033.0900制程用冷却水(T/H)46.36制程用冷冻水(T/H)155.4加热量(KW)0.0047.69加湿量(Kg/hr)0.0010.17加热用蒸汽量加湿用蒸汽量0.0030.81總冷卻量(kw)0.00總冷卻量(USRT)0.00冷卻水溫差(℃)5冷卻水量(m3/hr)0.00Header管徑(mm)0.00制程用蒸汽KG)供热用蒸汽KG)制冷单位负荷(W/M2)120.01供热单位负荷(W/M2)132.478.冷卻水塔12.蒸汽用量絕對溼度g/kg比容(m3/kgair)焓值(kJ/kgAir)19.90.87382.70.910.746-8.818.80.81535.4---8.80.839449.30.83844.8小计3600015.077.20018.004.238.400.0000.0040.72050043.200600.0000046.36155.447.6910.17水量(lpm)#VALUE!水量(m3/hr)#VALUE!10.凝結水量工程名稱:顶正(天津)工程建築名稱:车间一1.空氣狀態乾球溫度(℃)濕球溫度(℃)露點溫度(℃)相對溼度(%)絕對溼度g/kg比容(m3/kgair)焓值(kJ/kgAir)外氣條件(夏)31.426.424.867.919.90.87382.7外氣條件(冬)-11620.910.746-8.81供風條件1817.617.596.812.50.83149.9室內要求條件3023.721.460160.86771.3冬天室內條件211612.9609.30.83844.82.無塵室狀態车间一(外侧)车间一(内侧)车间一(预留)小计潔淨等級樓板面積(m2)218419929605136高度(m)777外牆面積(m2)29892160118463333.外氣處理正壓換氣(次/hr)機台排氣(cmm)外氣需求(cmm)32.7629.8814.477.0410.068顯熱(kw)8.467.713.72潛熱(kw)11.5710.555.09冷卻量(kw)20.0318.278.80冷卻量(USRT)5.695.192.50OverCool(kw)13.5012.325.944.循環風量潔淨循環(次/hr)循環風量(cmm)05.室內發熱(1)熱貫流率(w/m2℃)1.891.891.89外牆傳導(kw)7.915.723.13(2)照明電力(w/m2)202020照明負荷(kw)43.6839.8419.2102.72(3)工作人員(人)65.5259.7628.8發熱量(w/人)显606060發熱量(w/人)潜175175175人員負荷(kw)显3.933.591.73人員負荷(kw)潜11.4710.465.0427.0人員負荷(kw)总15.4014.046.7736.2(4)設備(kw)402.6417.62001020.2(5)FCU(台數)FCU負荷(kw)0總和(kw)458467224126012846163186.86.循環冷卻冷卻量(kw)464.64472.69226.932184.5冷卻量(USRT)132.12134.4164.52進風溫度(℃)303030出風溫度(℃)冰水溫差(℃)555冰水流量(lpm)1331.971355.04650.537.冰水機總冷卻量(kw)476.11483.15231.971191.22總冷卻量(USRT)135.38137.3865.96冰水溫差(℃)555冰水流量(m3/hr)81.8983.1039.90Header管徑(mm)120.34121.2384.00制程用冷却水(T/H)3.63.6制程用冷冻水(T/H)2500.23.422500.2加热量(KW)-100.97-200.47-80.71-382.15加湿量(Kg/hr)19.7918.058.7046.54加热用蒸汽量加湿用蒸汽量總冷卻量(kw)1938.72水量(lpm)0.65總冷卻量(USRT)551.26水量(m3/hr)0.04冷卻水溫差(℃)5冷卻水量(m3/hr)333.46Header管徑(mm)242.838.冷卻水塔10.凝結水量制冷单位负荷(W/M2)218.00242.54241.63供热单位负荷(W/M2)-46.23-100.64-84.07147.2810358工程名稱:顶正(天津)工程建築名稱:车间二1.空氣狀態乾球溫度(℃)濕球溫度(℃)露點溫度(℃)相對溼度(%)絕對溼度g/kg比容(m3/kgair)焓值(kJ/kgAir)外氣條件(夏)31.426.424.867.919.90.87382.7外氣條件(冬)-11620.910.746-8.8供風條件1817.617.596.812.50.83149.9室內要求條件282219.56014.20.8664.5冬天室內條件211612.9609.30.83844.82.無塵室狀態淋膜车间制袋车间检品车间碗盖车间分切车间小计潔淨等級樓板面積(m2)2976690345103310335044.0高度(m)77777外牆面積(m2)29761117397.51190.51190.56871.53.外氣處理正壓換氣(次/hr)-0.5機台排氣(cmm)730外氣需求(cmm)556.4010.358.62510.3310.33596.0顯熱(kw)143.620.002.672.232.672.67潛熱(kw)196.510.003.663.053.653.65冷卻量(kw)340.130.006.335.276.316.31冷卻量(USRT)96.710.001.801.501.801.80OverCool(kw)156.480.002.912.432.912.914.循環風量潔淨循環(次/hr)循環風量(cmm)05.室內發熱(1)熱貫流率(w/m2℃)1.891.891.891.891.891.89外牆傳導(kw)19.120.007.182.557.657.65(2)照明電力(w/m2)202020202020照明負荷(kw)59.52013.86.920.6620.66121.5(3)工作人員(人)29.76020.717.2520.6620.66發熱量(w/人)显606060606060發熱量(w/人)潜175175175175175175人員負荷(kw)显1.790.001.241.041.241.24人員負荷(kw)潜5.210.003.623.023.623.6219.1人員負荷(kw)总6.990.004.864.054.864.8625.6(4)設備(kw)342.6876.947.752.540.81081468.5(5)FCU(台數)FCU負荷(kw)0總和(kw)423706370138209403463123486813781.46.循環冷卻0.0冷卻量(kw)606.680.0073.3465.8473.76140.96960.6冷卻量(USRT)172.500.0020.8518.7220.9740.08進風溫度(℃

1 / 20
下载文档,编辑使用

©2015-2020 m.777doc.com 三七文档.

备案号:鲁ICP备2024069028号-1 客服联系 QQ:2149211541

×
保存成功