雨淋系统可操作性运行方案报告

整理文档很辛苦,赏杯茶钱您下走!

免费阅读已结束,点击下载阅读编辑剩下 ...

阅读已结束,您可以下载文档离线阅读编辑

资源描述

苏州科技文化艺术中心雨淋系统介绍及运行方案SuzhouScience&CulturalArtCenter目录科文雨淋系统简介······························································2科文中心雨淋设备介绍及系统的工作原理································3雨淋阀···········································································3信号蝶阀········································································3雨淋控制系统··································································3雨淋泵组和稳压泵组·························································3系统工作原理··································································4科文雨淋系统目前状态分析··················································5雨淋泵···········································································5雨淋阀···········································································5信号蝶阀········································································5管路系统········································································5雨淋控制中心··································································5科文雨淋系统可行性方案探讨···············································6科文中心雨淋系统操作方案··················································7雨淋泵···········································································7信号蝶阀········································································7管路系统········································································7雨淋阀···········································································7雨淋控制中心··································································7SuzhouScience&CulturalArtCenter科文雨淋系统简介苏州科文中心雨淋灭火系统是一个开式系统,系统由开式喷淋头、闭式喷淋电子探测传感器、TycoDV-5电启动雨淋阀组、信号蝶阀、水流压力开关、西门子雨淋控制主机、Wilo90KW*3台雨淋泵和两台稳压泵1.5kw*2组成。中心雨淋系统服务区域及阀门、喷头类型:见下表:雨淋报警阀室F1195(大剧院)阀类型喷头类型服务区域雨淋阀开式喷头大舞台水幕系统雨淋阀开式喷头大舞台东侧雨淋阀开式喷头大舞台东侧雨淋阀开式喷头大舞台主舞台雨淋阀开式喷头大舞台主舞台雨淋阀开式喷头大舞台主舞台雨淋阀开式喷头大舞台主舞台雨淋阀开式喷头大舞台西侧雨淋阀开式喷头大舞台西侧雨淋阀开式喷头大舞台后台雨淋阀开式喷头大舞台后台雨淋报警阀室F235(小剧院)雨淋阀开式喷头表演台雨淋阀开式喷头表演台湿式报警间(B177)雨淋阀开式喷头锅炉1#雨淋阀开式喷头锅炉2#雨淋阀开式喷头锅炉3#雨淋阀开式喷头锅炉4#湿式报警间(B229)湿式报警阀闭式喷头地下室景物储存间合计由18组阀门来执行所服务区域的灭火工作。SuzhouScience&CulturalArtCenter科文中心雨淋设备介绍及系统的工作原理雨淋阀苏州科文中心选用的是DN150TYCODV-5型电启动膜片式雨淋阀。当膜片腔内充满超过2.5kg/cm2以上的水压时膜片就可完全切断供水管路和喷洒管路,使系统在没有火灾的情况下,消防水无法从供水管路通过雨淋阀进入喷洒管路。雨淋阀的开启方式有:电磁阀启动、手动紧急启动信号蝶阀在雨淋阀前后各有一手动信号蝶阀,主要作用是起维修隔断和监测作用。雨淋控制系统在本中心雨淋控制系统由探测器、监测模块、控制模块、雨淋控制主机组成雨淋控制网络。消控主机通过总线结构和信号模块、控制模块实现数据通讯。主要实现下列功能:探测器:探测保护区域的火警信号,反馈到消控主机监测模块:监测信号蝶阀、水流压力开关状态,反馈到消控主机控制模块:接受消控主机的信号,控制雨淋组上的电磁阀开启消控主机:综合处理输入的探测器信号、监测模块信号。输出报警、启动雨淋阀、启动雨淋泵功能。工作方式由手动和自动两种。在手动方式时,雨淋电磁阀的开启及雨淋泵的启动由人工完成。自动方式时所有输出由消控主机计算机自动完成。雨淋泵组和稳压泵组本中心有三台90KW雨淋泵,二用一备,每小时额定流量276m3/h/台。稳压泵组主要维持常态时供水管路内保持恒定的压力。主泵启动方式分为下列几种情况。1.自动:即水泵控制柜上选择开关置自动状态。此时水泵的开启由安装于供水管路上的压力开关控制(科文未使用)。2.手动:即水泵控制柜上选择开关置手动状态。此时水泵的开关由水泵控制柜启动/停止操作。3.强制启动:有两种方式可强制雨淋泵工作A)消控中心的手动强制启动。。B)喷洒管路上的流动压力开关。此时不论水泵控制开关在何种状态,二台水泵同时就被强制启动。SuzhouScience&CulturalArtCenter系统工作原理分布在保护区域的探测器,发出火灾报警信号传到雨淋控制主机经过综合处理后,雨淋控制主机自动输出雨淋电磁阀开启信号,导致雨淋阀隔膜腔压力下降,雨淋阀开启,供水系统内预作用的消防水向喷洒侧管路流动,并从开式喷头喷向保护区,执行灭火功能。同时,触发流动压力开关动作,启动雨淋主泵信号。若此时消防主泵不能自动启动,则由人工在雨淋控制主机上强制启动雨淋泵。SuzhouScience&CulturalArtCenter科文雨淋系统目前状态分析雨淋泵目前水泵主电源未合闸,控制电源正常。故任何启动信号也无法使水泵启动.雨淋阀1.大剧院的11组雨淋阀隔膜腔压力只有2kg/cm2.低于厂家要求的压力.雨淋阀目前未完全关闭.2.小剧院2组雨淋阀雨淋阀隔膜腔无压力,雨淋阀目前完全打开.3.锅炉4组雨淋阀隔膜腔内无压力,雨淋阀目前完全打开.4.地下室景物储存间使用的是湿式报警阀,目前末端管路内预作用消防水的压力为8kg/cm2.信号蝶阀1.大剧院,锅炉房雨淋阀前后的信号阀已关闭,合计30个.2.小剧院,景物储藏室前后的信号阀是开启状态,合计6个.管路系统目前管路内基本无压力,未完全充满消防水。雨淋控制中心目前在手动状态。所有的输出信号需人工切换。.从以上各设备的状态设置,目前此雨淋系统无法发挥其应有的作用。SuzhouScience&CulturalArtCenter科文雨淋系统可行性方案探讨经过仔细研究科文雨淋系统水泵电气控制、雨淋设备、消防控制中心等设备,为了使系统尽最大可能避免意外发生,下列条件必须在技术上予以保证:1.系统的启动点必须是唯一的,2.各区域必须相对的独立。3.一旦系统需要使用时,操作必须方便安全。4.适合平时管理检查及系统测试。基于以上几点考虑,制定了三个方案并进行了对比。设备状态方案一方案二方案三雨淋泵主电源合闸,控制选择开关置”停”。。主电源合闸,控制选择开关置”停”。拆除“流动开关强起控制线”及控制柜上手动及自动功能主电源合闸,控制选择开关置”停”。拆除“流动开关强起控制线”及控制柜上手动及自动功能。信号蝶阀开启开启开启雨淋阀隔膜腔充水,保持阀关闭隔膜腔充水(压力3.5-4kg/cm2)保持阀关闭隔膜腔充水(压力3.5-4kg/cm2)保持阀关闭供水管路预作用额定压力的消防水6kg/cm21)无压力的消防水(以F195表压力为零为基准)2)景物储藏室报警阀后充满6kg/cm2水压完全无消防水消防主机置“手动”置“手动”置“手动”优点实现了系统启动权限的集中化、灭火区域的独立化、以及响应的及时性1)实现了系统启动权限的集中化、灭火区域的独立化。2)使非火灾因素的损失最小化实现了系统启动权限的集中化、灭火区域的独立化。人为或意外的损失最小化缺点1)雨淋阀的意外开启(手动或隔膜的破损)或喷淋头的意外损坏将导致重大财产损失。1)雨淋阀的意外开启或喷淋头的意外损坏会使锅炉或景物储藏室遭受雨淋。2)剧院区域的响应略有延时(约2-10S内)有延时效应(约60S以内)。SuzhouScience&CulturalArtCenter科文中心雨淋系统操作方案雨淋泵控制开关状态:置“停”位水泵主电源合闸,控制柜选择开关按钮置“停”.,拆除水泵控制电路“流动开关强起控制线”及手动和自动控制功能.目的实现水泵启动的控制权限集中在消控中心.信号蝶阀状态:置“开”目的:火灾时无须再进行手动开启.保证系统及时响应.管路系统状态:供水管路:无压力的消防水(以F195表压力为零为基准)喷洒管路:1)景物储藏室湿式报警阀后充满6kg/cm2水压.其余为空.目的:防止因雨淋阀人为开启或橡胶隔膜破裂,造成财产损失.雨淋阀状态:置“隔膜”充压.压力为3.5-4kg/cm2目的:实现各灭火分区的独立化。.雨淋控制中心状态:置“手动位置”目的;防止系统误动作。一旦收到火警信号和相关人员启动指令,转换到自动状态,并强制开启雨淋主泵。以上各设备设定可以保证雨淋系统启动点的唯一性、灭火分区的独立化和响应的及时性,以及平时测试的方便性。起草人:时间:审核人:时间:批准人:时间:SuzhouScience&CulturalArtCenter附件:损失评估:方案一:1.大剧院、小剧院任何一组雨淋阀的意外开启将导致该雨淋阀服务区域至少100-150M2被消防水淋.2.锅炉区域任何一组的雨淋阀开启将导致一台锅炉电控柜损失及炉体被高压水淋.3.地下室景物储存间任何一个自喷意外破裂将导致约2-4M2范围被水淋.结合以上分析,雨淋阀的意外开启将会导致较大的经济损失.方案二:1.锅炉区域的雨淋阀意外开启将导致某一台锅炉电控柜损失及炉体被低压消防水淋.2.地下室景物储存间任何一个自喷意外破裂将导致约2-4M2范围被水淋.雨淋阀意外开启导致的损失有限.方案三:若意外发生仅使地下室景物储存间有限的范围内被水淋.SuzhouScienceCultural&ArtCenter科文中心雨淋系统操作方案实施前、后测试结果方案实施前负责人测试项目测试结果确认奚工在水泵手动、自动控制线拆除时,现场按钮无法启动水泵正常水泵主电源已合闸正常水泵控制电源正常正常马工三台雨淋主泵由消控中心强制启动(已修复)正常现场信号蝶阀有信号反馈到消控中心正常消控中心有信号输出到雨淋电磁阀有2个坏(177)现场雨淋电磁阀和主机CRT显示一一对应正常流动开关启动主泵直接启动王工供水管路和出水管路阀门

1 / 11
下载文档,编辑使用

©2015-2020 m.777doc.com 三七文档.

备案号:鲁ICP备2024069028号-1 客服联系 QQ:2149211541

×
保存成功