Lo油田机械动态无功补偿装置说明书江苏默顿电气有限公司Lo-2-目录一.产品概述················································································-3-二.相关国家标准········································································-3-三.产品原理及框架图···································································-4-四.技术性能描述············································································-7-1.1技术条件···················································································-7-1.2操作流程···················································································-7-1.3装置的防护等级········································································-13-1.4指示灯、按钮导线·····································································-13-1.5电气间隙和爬电距离·································································-13-1.6装置的介电强度······································································-13-1.7安全防护··············································································-14-五.注意事项·············································································-15-Lo-3-一、产品概述SVC无功补偿装置是我公司针对油田机械、冶金、煤炭、电气化铁路等专业开发的项目;装置的主要元器件:电容器、电抗器、晶闸管阀等;SVC的装置是“静止”的(相对于调相机之类的旋转设备而言),但其功能是动态无功功率补偿。凡是需要对无功进行连续控制或快速控制的场合可以用SVC来满足以下一个或多个要求:改善电压控制;提高静态和动态稳定性;降低暂时过电压;阻尼系统的低频和次同步振荡;减小电压和电流的不平衡;减小因电压波动引起的设备出力率低下;抑制谐波;提高功率因数。以调节方式的不同,产品分为两大类:一类是晶闸管控制的;一类是利用铁磁饱和特性调节的;(静止无功补偿器晶闸管控制电抗器晶闸管投切电容器协调配合协调控制母线电压容性无功感性无功)。应用场合有室内型(柜体采用敷铝锌板,表面喷塑处理)装置和室外型(不锈钢)装置。对的低压无触点式动态无功补偿装置根据系统实际无功需求,采用瞬时无功理论、小波分析、动态测量计算并合理动作,采用SVC动态无功补偿调节器,对多只电容器组进行快速投切,控制可调电抗进行无级调节;为电力系统提供动态无功功率。SVC无功补偿装置,能够详细精确地控制无功电流,同时,可以在系统产生的较为严重的谐振时退出所有补偿电容器的优点,提高大扰动时补偿器运行的灵活性以及减少稳态运行时的损耗,我们开发了TSC+TCR型SVC补偿器;该TSC+TCR型SVC装置可以互补各自的局限性,装置通过无功补偿器的智能判断触发TSC模块来调节滤波电容,补偿容性无功,触发TCR模块来调节电抗器,补偿感性无功;实现无功功率的无级平滑调节,而且能够智能调节容性无功和感性无功,精确补偿无功功率;并在过负荷情况下保护装置。二、动态无功补偿装置符合的相关国家标准产品满足的技术参数和要求以及如下的专用标准:GB/T191-2008包装储运图示标志GB/T3047.1-1995高度进制为20mm的面板、架和柜的基本尺寸系列JB/T9663-1999《低压无功功率自动补偿控制器》JB/T5346-1998《串联电抗器》GB/T12326-2008电能质量电压波动和闪变Lo-4-GB/T13384-2008机电产品包装通用技术条件GB/T14549-1993电能质量公用电网谐波GB/T15543-2008电能质量三相电压不平衡GB/T17626.5电磁兼容试验和测量技术浪涌(冲击)抗扰度试验(idtIEC61000-4-5)GB/T19862-2005电能质量监测设备通用要求三、产品原理及框架图Lo-5-Lo-6-柜体技术要求:1、柜体规格:GCK型材800宽*550深*1780高、提供接地排支架及两侧封板;2、数量:7台3、颜色:电脑灰.喷粉涂装厚度40μ。4、提供安装接线端子的支架和后门散热风机启动电容安装支架5、前门做加强筋。Lo-7-四、设备/材料技术性能详细描述1.1技术条件额定电压:AC380V额定频率:50HZ补偿容量:例:250KVAR(可按总装机容量配置)主接线:Δ/Y接线海拔高度:2000米以下;环境温度:-20℃~+65℃;相对湿度:5~95%,25℃时相对湿度短时可达100%;安装倾斜度:≤5%最大日温差:≤15K周围空气没有明显的尘埃、烟、腐蚀性或可燃性气体、水蒸气或盐的污染.1.2操作流程1、确认三相四线、PE接地无误;2、按下装置启动按钮(绿色)装置进入开机自检,电压表显示电压参数,等待五秒进入控制器界面;3、相序位置说明相序垂直排列水平排列前后排列L1相上左远L2相中中中L3相下右近中性线最下最右最近Lo-8-4、控制器设置说明Lo-9-Lo-10-Lo-11-Lo-12-Lo-13-1.3装置的防护等级装置的防护等级符合GB/T-15576的规定达到IP44。1.4指示灯、按钮导线1、装置中所选的指示灯和按钮的颜色符合GB2682之规定。2、装置中所选用导线及母线的颜色符合GB2681之规定。1.5电气间隙和爬电距离1、装置内的电器元件符合各自的相关规定,并在正常使用条件下,保持其电气间隙和爬电距离。2、装置内不同极性的裸露带电体之间,以及它们与外壳之间的电气间隙和爬电距离不小于表1之规定。表11.6装置的介电强度1、主电路和其直接连接的辅助电路能耐受表3规定的试验电压不与主回路直接连接的辅助电路能耐受表2规定的试验电压表2额定绝缘电压U(V)电气间隙mm爬电距离mmU≤605560<U≤300610300<U≤660814660<U≤8001020800<U≤15001428Lo-14-1.6安全防护1、对直接触电的防护依靠装置本身的结构措施。2、装置的金属壳体、可能带电的金属件及要求接地的电器元件的金属底座(包括应绝缘损坏可能会带电的金属件)与接地螺钉间具有可靠的电气连接,其与接地螺钉间的连接电阻值符合规程要求。3、接地保护导体的截面积不小于表3的规定值。表3额定绝缘电压U(V)试验电压(有效值)VU≤60100060<U≤3002000300<U≤6602500660<U≤8003000800<U≤100035001000<U≤15003500额定绝缘电压U(V)试验电压(有效值)VU≤1225012U≤60500U>602Ui+1000,但不小于1500相导线的截面积S相应保护导体最小截面积S≤16S16<S≤3516S>35S/2Lo-15-五、注意事项1、装置必须安全接地,相序不能接反(ABCN)正确顺序连接;2、取样电流必须取自次总柜A相电流互感器二次侧,极性不能接反;3、CT电流变比设定必须与次总柜电流变比相符;(如:1000/5设定变比应为200)4、实际操作需严格按参数设定,不得另设参数。Lo-16-江苏默顿电气有限公司地址:常州市天宁区青洋北路3号电话:0519-88777733传真:0519-88772098服务热线:400-0519-500技术支持:0519-88772698售后热线:0519-85503992售后手机:13372262929网址::jsmodun@163.com