第六章建筑电气工程目录1.配电箱(盘)安装···························································································12.电线、电缆导管和线槽敷设················································································93.电线、电缆导管和线槽敷线··············································································144.普通灯具安装·······························································································195.插座、开关、风扇安装····················································································226.建筑照明通电运行·························································································257.接地装置安装······························································································258.避雷引下线和变配电室接地下线敷设··································································319.建筑等电位连接····························································································33北京惟明力通工程监理有限责任公司建筑电气部分-1-1.配电箱(盘)安装1.1施工前期准备序号检查方式控制项目控制要点备注1巡视检查施工现场条件1)安装配电箱(盘)孔洞预留尺寸是否合适、位置是否符合图纸要求;2)检查接地引线是否到位;3)检查土建粉刷是否完毕,具备安装条件;4)检查施工人员、工机具是否到位;5)检查辅材是否合格2见证检查箱(盘)到场情况1)再次核查箱(盘)防止二次搬运造成损坏;2)检查箱(盘)内元器件是否完好,有无锈蚀;3)检查专用工具和易损件备品、门柜钥匙是否齐全,并妥善保管;3见证检查技术准备条件1)检查有、无技术交底;2)检查施工人员上岗资格证书;3)检查施工单位质量保证体系能否正常开展工作;北京惟明力通工程监理有限责任公司建筑电气部分-2-1.2配电箱(盘)安装质量控制序号检查方式控制项目控制要点备注1见证基础型钢安装1)基础型钢安装的不直度小于5mm/全长、水平度5mm/全长、位置误差及不平行度5mm/全长;2)基础型钢按装后,其顶部宜高出抹平地面10mm,并有明显可靠接地;2见证箱(盘)稳固1)箱(盘)安装在震动场所,应按设计要求采取防震措施;2)箱(盘)及内部设备与各构件间连接应牢固:3)箱(盘)不宜与基础型钢焊死;4)箱(盘)应安装牢固,其垂直偏差不应大于3mm;5)箱(盘)暗装时,箱(盘)四周应无空隙,器面板四周边缘应进贴墙面,箱体与建筑物、构筑物接触部分应涂防腐漆;北京惟明力通工程监理有限责任公司建筑电气部分-3-1.3箱(盘)上电器安装序号检查方式控制项目控制要点备注1见证电器安装1)电气元件良好,型号、规格应符合设计要求,外观应完好,且附件齐全,排列整齐,固定牢固,密封良好;2)各电器应能单独拆装更换而不影响其它电器及导线束的固定;3)熔断器的熔体规格、自动开关的整定值应符合设计要求;4)信号回路的信号灯、光字牌、电铃、电笛、事故电钟等应显示准确可靠工作;5)盘上装有装置行设备或其它有接地要求的电器,器外科应可靠接地;2见证端子排安装1)端子应有序号,端子排应便于更换接线方便;离地高度宜大于350mm;2)强、弱电端子宜分开布置;当有困难时,应有明显标志并设空端子隔开或设加强绝缘的隔板;3)潮湿环境宜采用防潮端子;4)二次回路的连接件均应使用铜质制品;绝缘件应采用自熄性北京惟明力通工程监理有限责任公司建筑电气部分-4-阻燃材料;5)箱(盘)的正面及背面各电器、端子排等应标明线编号、名称、用途及操作位置,其标明的自己应清晰、公正,且不易脱色1.4箱(盘)二次回路接线质量控制序号检查方式控制项目控制要点备注1见证箱(盘)内二次回路接线1)导线与电气元件见采用螺栓连接、插件、焊接或压接等,均应牢固可靠。2)盘、柜内的导线不应有接头,导线芯应无损伤;3)电缆芯线和所配导线的端部均应标明其回路编号,编号应正确,自己清晰且不易脱色;4)配线应整齐、清晰、美观,导线绝缘应良好,无损伤;5)每个接线端子的每侧接线宜为1根,不得超过2根。对于接插式端子,不同截面的两根导线不得接在同一端子上;对于螺栓连接端子,当接两根导线时,中间赢家平垫片;6)二次回路应设专用螺栓;7)盘、柜内的配线电流回路应采用电压不低于500V的铜芯绝缘导线,器界面不应小于2.5mm2;其它回路界面不应小于1.5mm2;对北京惟明力通工程监理有限责任公司建筑电气部分-5-于电子元件回路、弱电回路采用锡焊连接时;在满足载流量和电压降基有足够机械强度的情况下,可采用不小于0.5mm2截面的绝缘导线;8)用于连接门上的电器控制台板等可动部位的导线尚应符合下列要求:○1应采用多股软导线,敷设长度应有适当裕度;○2线束应有外套塑料管等加强绝缘层;○3与电气连接时,端部应绞紧,并应加终端附件或搪锡,不得松散、断股;○4在可动部位链段应用卡子固定。2见证引入盘内的缆线连接1)引入盘、柜的电缆应排列整齐,编号清晰,避免交叉,并应固定牢固,不得是所接端子排受机械应力;2)铠装电缆在进入盘、柜后,应将钢带切断,切断处的端部应扎紧,并应将钢带接地;3)使用与静态保护、控制等逻辑回路的控制电缆,应采用屏蔽电缆。其屏蔽层应按设计要求的接地方式予接地;4)橡胶绝缘的芯线应外套绝缘管保护;5)盘、柜内的电缆芯线,应按垂直或水平有规律地配置,不得任意歪斜交叉连接。备用芯长度应留有适当余量;6)强、弱电回路不应使用同一根电缆,并应分别成束分开排列;北京惟明力通工程监理有限责任公司建筑电气部分-6-1.5工程试验序号检查方式控制项目控制要点备注1见证低压电器试验1)测量低压电器连同所连接电缆及二次回路的绝缘电阻;2)电压线圈动作值校验;3)低压电气动作情况检查;4)低压电气采用的脱扣器的整定;5)测量电阻器和变阻器的直流电阻;6)低压电器连同所连接电缆及二次回路的交流耐压试验;7)测量低压电气连同所连接电缆及二次回路的绝缘电阻值不应小于1MΩ:在比较潮湿的地方,可不小于0.5MΩ;8)低压电器动作情况的检查,应符合下述规定:对采用电动机或液压、气压传动方式操作的电气,处产品另有规定外每当电压、液压或气压在额定值的85%~110%范围内,电气应可靠工作;9)低压电器采用的脱扣器的整定,各类过电流脱扣器、失压和分励脱扣器、延时装置等,应按使用要求进行整定;10)低压电气连同所连接电缆及二次回路的交流耐压试验,应符合下述规定:试验电压为100V。当回路的绝缘电阻值在10MΩ以上时,可采用2500V兆欧表代替,试验持续时间为1min;11)漏电开关动作灵活可靠,动作电流不大于30mA,动作时间不大于0.1S。北京惟明力通工程监理有限责任公司建筑电气部分-7-1.6箱(盘)交接验收序号检查方式控制项目控制要点备注1见证配电箱(盘)交接验收1)检查配电箱(盘)的安装和回路编号;2)检查产品的说明说、合格证等技术文件、专用工具和备品备件;3)检查安装技术记录和试验记录;(包括影像资料)4)检查箱(盘)多余孔洞封堵、内部清理、控制回路标识、暗式箱盖固定、焊接防腐处理;5)做好进入维护期的各项和准备工作;北京惟明力通工程监理有限责任公司建筑电气部分-8-1.7配电箱(盘)安装安全管理序号作业项目危险点防范类型预控措施1配电箱(盘)搬运搬运倾倒、磕碰、砸伤搬运时要齐心协力、互相照应提醒避开障碍物防止磕绊;保持搬运通道通畅;搬运时要绑牢、捆稳、垫好软垫,防止损伤人身、设备;装卸时严禁野蛮抛、扔,轻装、轻卸;2配电箱(盘)支架制作、安装工具使用不当人身伤害、触电使用砂轮切割机加工支架时,要防止砂轮片破裂伤人;使用射钉枪稳固时,防止弹头回弹伤人;使用电焊机时,检查好接地线和焊把线防止漏电伤人;按规定穿好防护服装,特别注意在潮湿环境下电焊作业的漏电保护;按规定距离设置电焊机专用闸箱,保证一机、一闸、一漏、一箱、一锁;进行电气焊作业时必须开具动火票,并按规定处理作业附近易燃物;工作完毕撤离现场时,要注意关闭临时电源;3配电箱(盘)稳固就位安装倾倒、砸伤箱(盘)就位时,严禁野蛮搬撬,防止倾倒、坠落伤人和设备;北京惟明力通工程监理有限责任公司建筑电气部分-9-4配电箱(盘)试验电气试验触电非试验人员不得随意操作试验设备;试验过程中非试验人员严禁靠近试验设备;正确使用试验设备,试验后要进行放电;2.电线、电缆导管和线槽敷设2.1电线导管敷设质量控制序号检查方式控制项目控制要点备注1见证线材、管材进场检查1)材料外观良好,符合设计要求,三证齐全有效;2)内外经符合相关规范规定,管壁厚度应均匀一致,无凸棱凹陷,内外壁应光滑无毛刺;3)螺栓、螺丝、膨胀螺栓、螺母、垫圈等应采用镀锌件;4)金属灯头盒、开关盒、接线盒等,盒板厚度应符合华北标办图集的要求,镀锌层无脱落,无变形开焊,敲落孔完整无缺,面板安装孔与地线焊接脚齐全;5)材料分批次进场,要按规定比例分批抽检,与样品核对;6)检查材料保管条件,防止潮绣、变形和丢失等;7)检查施工方材料采购计划落实情况;8)代用材料必须取得甲方和设计同意,方能进场;北京惟明力通工程监理有限责任公司建筑电气部分-10-2见证管路配置1)路径、位置、方式符合设计规定;2)弯曲部分(弯曲半径、弯扁度)符合GB50303-2002规定;3)管口平整、光滑,管路横平、竖直;4)与其他管线的距离符合GB50303-2002规定;5)管线及附件防腐、接地或接零符合设计规定;6)在埋有电线保护管的大型设备基础模板上,应标有测量电线保护管引出口坐标和高程用的基准点或基准线;7)埋入建筑物、构筑物内的电线保护管、支架、螺栓等预埋件,应在建筑工程施工时预埋;8)预留孔、预埋件的位置和尺寸应符合设计要求,预埋件应埋设牢固;9)电气线路经过建筑物、构筑物的沉降缝或伸缩缝处,应装设两端固定的补偿装置,导线应有余量;10)配线工程采用的管卡、支架、吊钩拉环和盒(箱)等黑色金属附件,均应镀锌或土防腐漆;11)线路若有变化时必须及时在原图上进行标注,做竣工图时的依据,并及时办理变更或洽商,涉及费用时及时办理工程变更费用报审表;北京惟明力通工程监理有限责任公司建筑电气部分-11-2.2电缆导管敷设质量控制序号检查方式控制项目控制要点备注1见证电缆管进场检查1)材料外观良好,符合设计要求,三证齐全有效;2)内外经符合相关规范规定,管壁厚度应均匀一致,无凸棱凹陷,内外壁应光滑无毛刺;3)螺栓、螺丝、膨胀螺栓、螺母、垫圈等应采用镀锌件;4)材料分批次进场,要按规定比例分批抽检,与样品核对;5)检查材料保管条件,防止潮绣、变形和丢失等;6)检查施工方材料采购计划落实情况;7)代用材料必须取得甲方和设计同意,方能进场;2见证电缆管制作检查1)每根电缆管的弯头数:一般弯头≤3个;直角弯头≤2个;2)弯曲部分(弯曲半径、弯扁度)符合GB50303-2002规定;3)电缆管内径按设计规定不小于1.5倍电缆外径,管内光滑通畅,无积水、杂物;3见证电缆管敷