水泵选型计算公式一、水泵选型计算1、水泵必须的排水能力流量:QB=2024maxQm3/h2、水泵扬程估算H=K(HP+HX)mHP:排水高度;HX:吸水高度;K:管路损失系数,竖井K=1.1—1.5;斜井<20°时K=1.3~1.35;=20°~30°时K=1.25~1.3;>30°时K=1.2~1.25二、管路选择计算1、管径:'900'VQdnmQn:水泵额定流量;'V经济流速m/s;'Vp=1.5~2.2m/s;'Vx0.8~1.5m/s;'dx='dp+0.025m2、管壁厚计算CPdPPPp)65.0(230*)65.0(230211mmdP:标准管内径mm;P:水管内部工作阻力P=0.11Hsy(测地高度m)Kg/cm2;:许用应力,无缝管=8Kg/mm2,焊管=6Kg/mm2,C=1mm;3、流速计算2900dQVnm/s三、管路阻力损失计算gVgdLVh22*22m;总阻力损失计算hw=(hp+hx+gVp22)*1.71.7:附加阻力系数四、水泵工作点的确定H=Hsy+RQ2m;22QHQHHRWSYHsy:测地高度m五、校验计算①吸水高度:Hx=Hs-hwx-gVx22m;②η2=85%~90%ηmax;③稳定性:Hsy≤0.9H0六、电机容量计算cmmmHQKN102*3600Kw;c:传动效率,直联时c=1,联轴节时c=0.95~0.98;K备用系数Qm<20m3/h,K=1.5;Qm=20—80m3/h,K=1.3—1.2;Qm=80—300m3/h,K=1.2—1.1;Qm>300m3/h,K=1.1;水力计算参数表名称简图局部阻力系数ξ弯管d/R0.40.50.60.81.0*1.21.41.61.82.0ξ900.1370.1450.1580.2060.2940.4400.6611.0971.4081.978当弯管角度φ为非90°时,ξφ=ξ90°*φ/90°异径管变径锥角α﹤7°10°~15°20°~30°45°~55°ξ0.20.50.6~0.70.8~0.9当水由大头流向小头时ξ=0.16~0.3三通水流不拐弯ξ=0.1水流拐弯ξ=1.5滤水器有底阀d405075100150200250300ξ12108.57.06.05.24.43.7无底阀ξ=2~3闸板阀开启高度h/d1/82/83/84/85/86/87/8全开ξ97.8175.522.060.810.260.07*0.00逆止阀开启角度α(°)1520253040506070ξ90624230146.63.21.7*沿程阻力系数λ管子直径5075100125150175200225λ0.04550.04180.0380.03520.03320.03160.03040.0293管子直径250275300325350400450500λ0.02840.02760.0270.02630.02580.0250.02410.0234