六系列说明书V12

整理文档很辛苦,赏杯茶钱您下走!

免费阅读已结束,点击下载阅读编辑剩下 ...

阅读已结束,您可以下载文档离线阅读编辑

资源描述

产品使用说明书(六系列探测器模块)目录1.0火灾探测器1.0.1JTY-GD-OT602点型光电感烟火灾探测器··········································11.0.2JTY-GD-OT302点型光电感烟火灾探测器··········································31.0.3JTW-ZD-OT603点型感温火灾探测器(A2)······································51.0.4JTW-ZD-OT306点型感温火灾探测器(A2)······································72.0按钮2.0.1JSA-M-OA610手动火灾报警按钮························································92.0.2OX620-QG消火栓按钮·······································································112.0.3ODZ52按钮底座···················································································133.0模块3.0.1OM621(OM611)输入/输出模块·····························································143.0.2OM622输入模块···················································································163.0.3OM613中继模块····················································································183.0.4OMDZ51模块底座··················································································203.0.5ODZ3007底座························································································223.0.6ODZ6004底座························································································233.0.7OM515隔离模块··················································································244.0消防警铃4.0.1OJL01消防警铃·····················································································255.0声光警报器5.0.1OS631火灾声光警报器······································································266.0地址编码器6.0.1OBM地址编码器····················································································2811.0概述1.1JTY-GD-OT602点型光电感烟火灾探测器(以下简称探测器)是我公司成功研制的新一代智能火灾探测器,该探测器采用红外散射原理设计,内置先进的MCU微处理器,具有现场参数采集,自动检测探测器两端电压等功能,制造工艺采用先进的SMT贴片技术。完善的屏蔽措施,对电磁环境恶劣场所有着很好的抗干扰能力。同时也采用了防潮湿、防腐蚀、防霉变等措施,对沿海高潮湿地区有着很好的防护能力。1.2该探测器采用电址编码器编址,编址后与我公司生产的OZH4800等火灾报警控制器配合使用,探测器正常工作时,红灯闪亮,当检测到火警信号时红灯常亮。1.3JTY-GD-OT602代表意义:JT:探测器专用符号,Y:感烟;GD:光电;0:ORENA;T:探测器6:6系列;02:感烟类。1.4符合标准《GB4715-2005点型感烟火灾探测器》。2.0结构特征及工作原理2.1壳体材料和颜色采用ABS复合塑胶注塑成型,外观美观、安装方便。2.2工作原理、工作特性该探测器原理是通过红外光线传感器来测量烟的浓度,探测器的迷宫在结构设计时,红外光束是偏离传感器。当烟雾进入到迷宫内,烟雾粒子会将部分光束散射到传感器上。若烟雾浓度逐渐增加,就会有更多的光束被散射到传感器上,在达到一定的浓度探测器就会报警,报警时探测器指示灯常亮,并向控制器反馈火警信号,直到复位控制器。控制器通过检测回路中探测器反馈的火警信号启动控制设备。2.3主要部件该探测器是由迷宫体、红外发射管、红外接收管、一块线路板、外壳主要部件组成。3.0技术特征3.1工作电压:DC20V~30V3.2监视电流:≤400uA报警电流:≤2mA3.3线制:二线制,无极性3.4环境条件:温度-10℃~+50℃。相对湿度≤95%(40±2℃)3.5尺寸及重量直径:100mm高度:40mm重量:约82g4.0安装4.1安装基础、条件及要求4.1.1探测器对烟雾、灰尘、水雾及挥发性气体敏感,因此对那些灰尘大、经常有水雾等场所不适用;另外风速≥5m/s的风口也不宜安装,因为这些地方烟雾很难积聚。4.1.2安装前探测器应保存在防尘、防潮、防霉的地方。4.2探测器的布线4.2.1要求用截面积1mm2以上的铜质双绞线,每米绞合节数为20~30,导线总电阻低于60Ω,总分布电容低于0.2uF。在总线负载较重的情况下,宜根据实际最大负载电流计算导线压降,以保证现场单元得到20V以上的总线电压。4.2.2屋顶的穿线管在装入底座后应使用密封膏或密封胶封堵,防止积水进入探测器。4.2.3接线时导线应使用冷压接线端子或做镀锡处理,不可随意缠绕。避免线头接触不良。4.2.4探测器接线:1端和2端接火灾报警控制器总线(不分极性),所有探测器之间并联连接。(如下图)JTY-GD-OT602点型光电感烟火灾探测器使用说明书43.8MM12312312332150mm80mm迷宫指示灯24.3安装程序、安装调整方法及注意事项4.3.1底座安装a.安装前应首先检查探测器外壳是否完好无损,标识是否齐全。b.OT602底座的型号为ODZ6004,安装时可采用86H50型预埋盒或其它安装孔距为40~85mm的预埋盒。c.事先选择好位置或在墙体上打出深度为30mm以上Φ5孔径,用二枚塑料膨胀栓、插进钻的孔中。塑料膨胀栓应该和墙体表面齐平。用自功螺钉把底座安装在塑料膨胀栓孔中。在拧紧螺丝钉前,查验一下火警灯指向正确的位置。如果不正确的话,调整方向,拧紧螺丝钉。4.3.2探测器安装a.采用电址编码器或控制器自动编址对探测器进行编址,并将编好的地址记录下来以备查询。b.应在工程装修完毕后安装,在安装探测器前,应检查安装导线对地绝缘电阻(用500V兆欧表量)是否大于20MΩ,同时应检查总线电压是否正常。探测器底部侧面和底座侧面各有一凸棱,底座上有一卡槽。安装时先将探测器凸棱对准底座旁的卡槽,接着将探测器放入底座卡槽中,最后顺时针旋转探测器直至探测器凸棱和底座凸棱对齐为止。4.3.3安装完后探测器必须可靠地卡在底座卡槽中并且凸棱和底座凸棱对齐,否则重新安装。5.0功能描述5.1探测器正常工作时红灯应能闪亮。5.2对探测器进行加烟,探测器应报警,指示红灯常亮;报警指示应予保持,直到复位火灾报警控制器。6.0故障分析与排除故障现象原因分析排除方法备注相连接的主机或设备报故障1.外部接线错误2.导线松动3.安装时探测器未完全卡入底座1.按接线图更改错误接线。2.紧固接线螺丝。3.卸下重新安装连接设备仍无法正常工作,请与厂家联系处理。易报火警1.迷宫体内有灰尘。2.安装环境不适合,如发电机房1.清除迷宫体内灰尘。2.更换适合安装环境。探测器仍无法正常工作,请与厂家联系处理。7.0维护、保养及维修7.1探测器没有其它可让用户自己更换的部件,出现故障,请与本公司联系。7.2维护、保养前应通知有关部门,该感烟探测器系统将要进行维护,暂时停止工作。切断将进行维护区域的电源或系统控制的逻辑控制功能。以免造成不必要的报警联动。7.3污染和积尘对烟雾检测室造成的影响如下表所示,应定期进行清洗、保养、至少一年进行一次。污染部位可观察到的现象导致结果处理方法防虫网污垢附着,堵塞网孔减少通烟面积失去报警功能.1.用湿布轻轻擦拭探测器的外壳,将外壳上网格里的灰尘擦拭干净。2.用手捏住迷宫体两侧,用棉棒或棉球蘸适量的酒精仔细清洁迷宫体内腔及镜头。3.清洁完毕后,小心安装好迷宫。注意:不要将棉絮纤维留在迷宫体内,否则会导致探测器误报警。8.0运输、贮存8.1产品内包装采用纸盒、泡沫;外包装采用纸箱等。8.2产品运输途中不应受雨、霜、雾直接影响,并不受挤压、撞击等损伤。8.3产品应贮存在通风、干燥、相对湿度小于85%的仓库中,离地面50mm以上;叠层高度不超过5层;周围应无腐蚀气体;贮存时间不超过12个月,超过12个月应重新进行性能检查。9.0开箱及检查9.1当您购买此产品时,应当场开箱检查,根据装箱清单对所有物品进行清点。9.2包装应完好无损。9.3开箱时若发现本产品有损坏或部件脱落松动,请及时通知本公司。10.0注意事项10.2在建筑物内部装饰完成前只允许安装底座,不允许安装探测器,以免建筑粉尘和涂料污染探测器。31.0概述1.1JTY-GD-OT302点型光电感烟火灾探测器(以下简称探测器)是我公司成功研制的新一代火灾探测器,该探测器采用红外散射原理设计,先进的SMT贴片制造工艺,完善的屏蔽措施,对电磁环境恶劣场所有着很好的抗干扰能力。同时也采用了防潮湿、防腐蚀、防霉变等措施,对沿海高潮湿地区有着很好的防护能力。1.2该探测器无地址,属于开关量探测设备,与接口模块或气体灭火控制器等配合使用。1.3JTY-GD-OT302代表意义:JT:探测器专用符号,Y:感烟;GD:光电;0:ORENA;T:探测器3:3系列;02:感烟类。1.4符合标准《GB4715-2005点型感烟火灾探测器》。2.0结构特征及工作原理2.1壳体材料和颜色采用ABS复合塑胶注塑成型,外观美观、安装方便。2.2工作原理、工作特性该探测器原理是通过红外光线传感器来测量烟的浓度,探测器的迷宫在结构设计时,红外光束是偏离传感器。当烟雾进入到迷宫内,烟雾粒子会将部分光束散射到传感器上。若烟雾浓度逐渐增加,就会有更多的光束被散射到传感器上,在达到一定的浓度探测器就会报警,报警时探测器指示灯常亮,并向控制器反馈火警信号,直到复位控制器。控制器通过检测回路中探测器反馈的火警信号启动控制设备。2.3主要部件该探测器由迷宫体、红外发射管、红外接收管、一块线路板和外壳组成。3.0技术特征3.1工作电压:接开关量输入设备或监视模块控制端DC24V3.2监视电流:≤70uA报警电流:≤20mA(电阻1k,电压DC24V)3.3线制:二线制,无极性3.4环境条件:温度-10℃~+50℃。相对湿度≤95%(40±2℃)3.5尺寸及重量直径:100mm高度:43.8mm重量:82g4.0安装4.1安装基础、条件及要求4.1.1探测器对烟雾、灰尘、水雾及挥发性气体敏感,因此对那些灰尘大、经常有水雾等场所不适用;另外风速≥5m/s的风口也不宜安装,因为这些地方烟雾很难积聚。4.1.2安装前探测器应保存在防尘、防潮

1 / 32
下载文档,编辑使用

©2015-2020 m.777doc.com 三七文档.

备案号:鲁ICP备2024069028号-1 客服联系 QQ:2149211541

×
保存成功