1目录1、施工组织设计····················································21.1编制依据··························21.2工程概况及施工条件··········································31.3施工目标····················································41.4主要施工方法简介············································41.5施工程序····················································51.6主要分部分项施工方法····················61.6.1施工测量···············································61.6.2施工开挖注意···········································51.6.3给水、消防管线施工······································71.6.4污水管线施工··········································121.6.5雨水管线施工··········································161.6.6热力管线施工··········································192.项目班子机构及劳动力安排·······································352.1项目班子机构:·············································372.2劳动力安排················································413.质量保证体系和保证措施··········································243.1建立完善、全面的质量管理体系································243.2建立健全完善的质量保证体系································243.3建立严格的工地质量管理制度·································243.4建立严格的材料进场管理制度································243.5建立完善质量检测体系·······································253.6建立完善的施工试验及送检制度······························253.7质量保证措施···············································263.8施工技术交底···············································303.9质保资料的整理、存档······································314.安全保证体系和保证措施··········································3121、施工组织设计1.1编制依据本工程施工组织设计按照建设单位招标及答疑文件等的要求和现场周边环境进行编制,未提之处均按照施工图纸设计、国家现行技术规范、规程、质量评定标准以及有关文件等要求的具体规定进行施工。编制依据如下:(1)《室外给水设计规范》〈GB50013-2006〉;(2)《建筑给水排水设计规范》〈GB50015-2003〉(2009年版);(3)《建筑设计防火规范》〈GB50016-2006〉;(4)《建筑给水排水及采暖工程施工质量验收规范》〈GB50242-2002〉;(5)《给水排水管道工程施工及验收规范》〈GB50268-2008〉;(6)《城镇给水排水技术规范》〈GB50788-2012〉;(7)《湿陷性黄土地区建筑规范》〈GB50025-2004〉;(8)《湿陷性黄土地区室外给水排水管道工程构筑物》〈S531-1~5〉;(9)《室外排水设计规范》〈GB50014-2011〉;(10)《给水排水构筑物工程施工及验收规范》〈GB50141-2008〉;(11)《城镇供热管网设计规范》CJJ34-2010(12)《城市供热管网工程施工及验收规范》GJJ28-2004(13)《城镇直埋供热管道工程技术规程》CJJ/T81-98(14)《直埋供热管道工程设计》(15)《室外排水设计规范》〈GB50014-2011〉3(16)《埋地聚乙烯排水管道技术规程》〈CECS164:2004〉;(17)《城镇给水排水技术规范》〈GB50788-2012〉;(18)九院小区三期工程及室外管线综合图设计.(19)太原市气象资料(20)本工程管线综合规划图、竖向规划设计图及单体建筑给排水专业施工图;(21)甲方委托的设计任务合同书;(22)现行的其它有关规范及规程。1.2工程概况及施工条件本工程为太原市九院小区三期室外工程施工图设计。本工程位于山西省太原市万柏林区,九院小区三期西邻开城路,南邻纬二路,东临西山北外环路,整个地块东西长约370.0m,南北长约130.0m。地势西高东低,南高北低,场地坡度较为陡峭。本工程总建筑面积约为170047.0m2,总户数约1930户(3.5人/户)。地质情况:本工程拟建场地为自重湿陷性场地,湿陷等级为Ⅲ级。勘察期间,本场地在勘察深度范围内,未揭露地下水。施工条件:2014年由于室外地下管线、挡土墙、庭院与主楼裙楼、独立商铺、办公楼同时施工,为了互不影响施工,最先进行2#楼消防水池方涵及各化粪池施工。1#、2#楼主楼北边东西走向管线和1#楼西边管线以及3#、4#楼北边东西走向管线受主楼施工影响,不能进行施工,待主体结构封顶后进行施工。410米小路上地下管线计划通长施工,为保证1#楼主楼施工材料及运输,须在10米小路开成路口处开门。施工经二路两侧所有地下管线施工时,需要封堵纬二路西边大门。为保证不影响4#楼主楼以及管线施工,保证材料运输,须在4#楼南边围墙处开门。3#、4#楼主楼南侧管线在纬二路上,为了不影响主楼施工(材料运输、浇筑主楼混凝土纬二路上需支泵车及罐车运输),则纬二路路面及树木不能进行破坏。纬二路上管线须在3#、4#楼主楼施工完毕后进行破路面及拆除马路牙和迁移树木后,方可进行施工。1.3施工目标(1)进度目标:室外工程计划于2014年3月20日开工,2015年9月1日竣工。(2)质量目标:工程质量达到“合格”标准,争创“市优”。(3)安全目标:杜绝死亡、重伤事故,轻伤事故频率控制在2‰以内。(4)文明施工目标:文明现场达标,创太原市文明施工样板工地。(5)环境保护目标:降低施工噪音,减少大气污染,控制污水排放,保持环境整洁。1.4工程的重点和难点2014年九院工程可分为三个主要目标及管理重点:第一个是商5铺主体及内装饰安装工程,第二个是室外管网道路及配套工程,第三个是主体及二次结构装饰安装工程。三个目标即独立又相互交叉,室外工程影响商铺的竣工,主体工程影响室外工程衔接。在不便于施工的条件下,努力创造施工条件,对室外管网进行划分区段进行施工,在保证不影响主体结构施工的情况下,同时开展室外管网的施工。1.5施工程序由于室外地下管线、挡土墙、庭院与主楼裙楼、独立商铺、办公楼同时施工,为互不影响,室外管网施工初步计划分两段进行施工,第一段施工不影响主体结构施工的各管线,待各楼主体施工完毕后,进行第二段其余管线施工。第一段室外管网施工计划2014年3月份中旬开始,首先进行施工的室外管网部位和时间如下:①、3月20日开始进行2#楼消防水池处方涵及管沟施工。②、4月20日开始进行10米小路上所有管线施工(从东边六建围墙处至经二路交叉口),为保证室外管网施工,不受主体施工影响,拟定分段施工,为保证分段施工的可操作性,10米小路计划通长施工,在10米小路开成路口处开门,以保证1#楼主体施工材料的进场。;③、4月20日开始进行1#楼、2#楼化粪池施工。④、5月20日开始进行1#楼裙楼、2#楼裙楼南边所有管线施工;⑤、5月20日开始进行4#楼北边的所有管线施工,确保在6月底完成。然后将4#楼原钢筋棚移至4#楼东北角,进行原钢筋棚处的管线施工(在4#楼东南角开门,作为施工通道)。6⑥、6月份开始经二路两侧所有管线施工,7月底结束(封堵纬二路西边大门)。⑦、6-8月份,进行4#楼原钢筋北区所有管线施工。⑧、确保8月10日完成所有主体结构施工,9月份开始进行主楼南侧以及其余室外管网施工。同时,10月中旬开始进行现场庭院、造型以及护坡等施工。第二段室外管网施工:待主体结构施工完毕后,进行第二段室外管网其余管线施工。1.6主要分部分项施工方法1.6.1施工测量1)、进入现场后,先探明地下各类管线,若遇重要管线,应及时通知甲方,进行保护。2)、进入施工现场后,根据设计资料和建设单位交付的控制点,认真校核各控制点高程及坐标,若与现状不符,应及时与设计单位和甲方联系。3)、导线复测采用全站仪,原有导线点不能满足施工要求时,应进行加密。4)、施工过程中,测量人员对平面和水准测量应准确及时,并应及时向施工人员提供测量数据并现场交桩,测量标志应坚固稳定,施工人员对测量标志应认真保护。5)、编制详细的施工测量方案,严格执行测量复测制度,并对所有的测量成果进行记录整理。76)、技术负责人应会同设计或勘测部门现场交接中线控制桩和设计水准点,并设置护桩,临设水准点应与设计水准点复测闭合。1.6.2施工开挖注意1)、施工前,应对开槽范围内的地上地下障碍物进行现场核查,逐项查清障碍物构造情况,以及与工程的相对位置关系。建议采取物探、坑探等方法查明地下管线和设施以防对其他地下管线和设施造成破坏,并在开挖过程中采取措施加以保护。当开挖管沟发现发现文物时,应采取措施保护并及时通知文物管理部门。2)、土方开挖中发现事先未查到的地下障碍物时应停止施工。应采取措施并经有关单位同意后,再进行施工。1.6.3给水、消防管线施工本工程的水源除换热站由九院二期供给外,其它水源均为本小区南侧市政路纬二路上的市政供水管线供给,市政入口压力为0.4MPa,其水质必须符合国家现行生活饮用水卫生标准的要求。1.6.3.1、管线布置:室外给水工程从本小区南侧纬二路接入市政给水管线后分两路供水,一路JS管线供给各个商铺,一路J1管线直供给各楼座低区生活用水、泵房中的无负压设备和消防水池;各楼座中、高区生活用水由J1管道直接接至泵房无负压设备,经叠压加压后分别供给各楼座(1#、2#、3#、4#号楼所共用的无负压设备与廉租房所使用的无负压设备相互独立);消防用水由消防水池经吸水管吸至消防泵加压后沿管道(其管道出泵房绕本小区外围成环敷设)分别供给个楼座,以满足各楼座室内外消防用水量需求。81.6.3.2、管材及接口:消防给水管采用内外壁热浸镀锌钢管,其接口采用法兰连接;生活给水管和商铺给水管采用钢丝网骨架塑料(聚乙烯)复合管,其接口形式为热容连接。1.6.3.3、管道敷设、基础及回填;管道敷设:本小区北侧部分管线由于场地局限,管线敷设方式采用管沟敷设;本小区东侧、南侧和西侧部分管线由于不满足三级湿陷性黄土地区建筑物对管道防护距离的要求,管线敷设方式为检漏沟敷设;其余管线均采用直埋敷设。其中管沟做法见室外热力管道施工图;检漏沟做法参见图集04S531.管道基础及回填土:根据单体提供,本工程地质情况为:1#、1#裙楼、3#、4#及3#和4#间的裙楼为Ⅲ级自重湿陷性黄土,2#、廉租房为Ⅱ级自重湿陷性黄土;给水管线不满足对湿陷性黄土地区防护距离要求的(在Ⅲ级自重湿陷性场地,甲类建筑的防护距离为8.0~9.0m,丙