HMDWR-5A接地阻抗测试仪

整理文档很辛苦,赏杯茶钱您下走!

免费阅读已结束,点击下载阅读编辑剩下 ...

阅读已结束,您可以下载文档离线阅读编辑

资源描述

1目录一、用途················································2二、概述················································2三、性能特点············································3四、技术指标············································3五、仪器内部结构和测试原理······························4六、仪器面板说明········································5七、仪器操作说明········································5八、工频接地阻抗的测量··································7九、场区地表电位梯度的测试······························9十、接触电位差、接触电压的测量·························10十一、跨步电位差、跨步电压的测量························10十二、土壤电阻率的测量··································11十三、查看历史数据······································12十四、异常处理··········································13十五、注意事项··········································13十六、与计算机的通讯····································13十七、装箱单············································14十八、可选配件··········································14十九、服务电话··········································142一、用途本仪器适用于测试各类接地装置的工频接地阻抗、接触电压、跨步电压、转移电位、场区地表电位梯度等工频特性参数以及土壤电阻率。本仪器采用异频抗干扰技术,能在强干扰环境下准确测得工频50Hz下的数据。测试电流较小(最大5A),不会引起测试时接地装置的电位过高,同时它还具有极强的抗干扰能力,故可以在不停电的情况下进行测量。二、概述目前国内接地装置的测试工作比较薄弱,一些关键的技术观念比较模糊,技术手段落后。针对上述现状,我国制订了最新行业标准DL/T475-2006和国家标准GB/T17949.1-2000。新标准对旧标准做了很多重要改变。为了方便广大现场测试和研究人员,我们根据这些最新标准,结合我们多年研究大型地网测试的实际经验,研制成功本仪器。工频接地阻抗,是指接地装置对远方电位零点间的电位差与通过接地装置流入地中的工频电流的比值。工频接地阻抗以往被习惯地称为“工频接地电阻”。此名称的纠正,在国家标准GB/T17949.1-2000“接地系统的土壤电阻率,接地阻抗和地面电位测量导则第一部分:常规测量”以及电力行业标准“接地装置特性参数测量导则修订稿”(取代DL475-92)中作了阐述。本测量仪采用交流电流进行测试,故所测数值称为接地阻抗,而不再沿用以往的称呼“接地电阻”。在对接地装置进行测量时,由于受不平衡零序电流以及射频等各种干扰,使得测试结果产生很大的误差。特别是大型接地网的接地阻抗一般很小(一般在0.5Ω以下),干扰带来的相对误差更大。为了降低现场干扰的影响,目前采用的方法主要有两种,一种是增大测试电流,一种是使用异频法。第一种方法是通过加大测试电流来加大信号电压和信号电流,从而提高信噪比,减小测量误差。这种方法由于采用了很大的测试电流(DL/T475-2006标准推荐不宜小于50A),使得设备非常笨重,且布线劳动强度很大,耗时耗力。而且,由于主要干扰与信号同频,无法从根本上消除干扰的影响。异频法则是通过改变测试电流的频率来避开工频干扰,由于信号频率与干扰频率不同,就可以通过滤波器来滤除干扰的影响,从而提高测量精度。异频法由于采用的测试电流较小,因此设备小巧,布线劳动强度也大大减轻。由于具有测试结果稳定可靠和省时省力的优点,异频法测试已被国内外专家广泛接受和采用。但是根据定义,工频接地阻抗是指接地装置在工频电流下呈现出的阻抗,而异频法采用的测试电流频率不为工频,因此测得的数值就会3与工频电流下测得的值有偏差。理论和实践表明,产生偏差的原因是,接地装置的接地阻抗是复数阻抗,不仅包含电阻性分量,还含有与频率有关的电感性和电容性分量。采用的测试频率与工频相差愈远则等效性愈差,即测量误差越大。为了保证测试的准确性,测试频率与工频不能相差太远,且测试电流的波形应为正弦波(其他波形如方波含有丰富的谐波频率)。早在70年代,美国、日本等国就规定了测试频率与工频之差不能超过10Hz。中国国家标准GB/T17949.1-2000要求测试电流频率应该尽量接近工频,行业标准DL/T475-2006规定了测试电流频率宜在40~60Hz之间。本仪器采用45Hz和55Hz两种频率进行测量,再计算出50Hz下的等效阻抗,因此测量的准确性和等效性进一步得到提高。三、性能特点1、测量的工频等效性好。测试电流波形为正弦波,频率与工频之差仅为5Hz,使用45Hz和55Hz两种频率进行测量。2、抗地电压干扰能力强。本仪器采用异频法测量,配合现代软硬件滤波技术,使得仪器具有很高的抗干扰性能,测试数据稳定可靠。30V工频干扰电压带来的误差仅为0.002Ω。3、精度高。可用来测量接地阻抗很小的大型地网。4、功能强大。可测量相关标准规定的接地装置的全部特性参数。不仅可测量接地阻抗,还可测量出电阻分量和电抗分量。可直接测量跨步电压、跨步电势、接触电压、接触电势、电位分布等。5、可测量现场干扰,方便用户估计测量误差。6、具备断线报警功能,避免了错误测量。7、操作简单。全中文菜单式操作,直接显示出测量结果。8、可保存50组测量数据,且自带微型打印机可现场打印测量结果。9、布线劳动量小,无需大电流线。10、本仪器体积小、重量轻,方便携带。11、具有RS232通讯接口,配备了客户端计算机软件,可用计算机软件来操作仪器。关于通讯软件的使用说明请参见随机光盘。四、技术指标1、阻抗测量范围:0~200Ω2、分辨率:0.001Ω3、测量误差:±(读数×1%+0.001Ω)4、抗地电压干扰能力:30V工频干扰电压带来的误差不大于0.002Ω4(测试电流不小于3A时)5、测试电流波形:正弦波6、测试电流频率:45Hz、55Hz双频7、最大输出电流:5A8、最大输出电压:400V9、测量线要求:电流线铜芯截面积≥2.5mm2电压线铜芯截面积≥1.0mm210、供电电源:AC220V±10%,50Hz11、使用环境:温度:-10℃~40℃;相对湿度:90%12、外形尺寸:440×350×31013、仪器重量:10.5kg五、仪器内部结构和测试原理本仪器主要由提供测试电流的异频电源、电流和电压测量电路以及微电脑测控系统组成。仪器通过测量接地装置的电位升高与流入接地装置的电流之比来测量接地阻抗。仪器内部结构如图1所示。异频恒流电源可输出频率为45Hz或55Hz的正弦波测试电流,输出频率受微电脑系统控制。其输出经过隔离后通过仪器面板上的C1、C2两个端子输出。电压放大器为一个高输入阻抗放大器,它将P1、P2两端的电压放大后送给滤波器。电流放大器将从电流互感器取得的电流信号进行放大后送给滤波器。滤波器用于滤除干扰信号,只允许45Hz和55Hz信号通过。A/D转换器用于将电压和电流信号转换为数字信号以便微电脑系统进行分析处理。用户启动接地阻抗测量后,仪器首先开启异频电源使之输出频率为45Hz的电流,待电流稳定之后,微电脑系统通过A/D转换器取得电压和电流波形数据,进行数字滤波后计算出电压V45和电流I45及其相位差,再进一步计算出阻抗Z45、电阻分量R45和电抗分量X45。然后,切换电流放大器45Hz/55Hz异频恒流电源电压放大器C11C2P1P2A/D转换器微电脑系统R232通讯接口液晶显示器微型打印机图1仪器内部结构图滤波器滤波器5异频电源的输出频率为55Hz,经过同样的步骤后可计算出阻抗Z55、电阻分量R55和电抗分量X55。取Z45和Z55的平均值作为工频接地阻抗Z50。最后,关闭异频电源,通过液晶屏显示测量结果。因此阻抗测量时,仪器测量的是两电压输入端P1、P2之间的电压与电源输出电流之比。六、仪器面板说明仪器面板布置如图2所示图2面板图1、接线端子:位于面板右侧,共有4个接线柱,分别是C1—电源输出端1,进行接地阻抗测量时接被测接地装置C2—电源输出端2,进行接地阻抗测量时通过电流线连接到电流极P1—电压输入端1,进行接地阻抗测量时接被测接地装置P2—电压输入端2,进行接地阻抗测量时通过电压线连接到电位极2、按键共4个按键,位于面板中下部。上箭头键一般用于增加数字或向上移动光标。下箭头键一般用于减小数字或向下移动光标。光标键主要用于移动光标。确认键主要用于确认已输入的数据或者执行光标处的命令。3、微型打印机位于面板之左上部4、液晶显示器液晶屏位于面板之中部偏右处5、电源输入插座6位于面板左下部,用于接入交流220V电源。6、电源开关船形开关向上时,仪器接通电源。七、仪器操作说明首先应根据实际使用需要,布置好测试回路并接好线,检查接线无误后方可打开仪器电源开关。注意,为了确保安全,接线时请将电源开关置于断开的位置。打开电源开关后,液晶屏首先显示“欢迎使用”约3秒,之后自动进入日期设置屏。此时可通过按键修改日期,按“确认”键后进入功能选择菜单。屏幕如下图所示:图3按一下或者“光标”键可改变待执行的功能选项,按“确认”键后,仪器执行光标所指示的功能。§7.1“测量接地阻抗”功能本功能主要用于测量工频接地阻抗。本文将在下面章节中详叙。§7.2“测量土壤电阻率”功能此功能用专门用于四极法测量土壤电阻率,输入电极间距后,仪器自动测量并计算出土壤电阻率。§7.3“跨步电压、接触电压”功能此功能用于测量接触电势、接触电压、跨步电势、跨步电压、转移电位、场区地表电位梯度等。§7.4“测量干扰电压”功能启动此功能后,现场干扰电压将被不断地测量并将其有效值显示出来,同时还显示其波形。按任意键可以退出此功能。§7.5“查看历史数据”功能本功能用于调出用户曾经测量并保存过的测量数据记录。本功能将在第十三节详述。请选择命令测量接地阻抗测量土壤电阻率跨步电势、接触电势测量干扰电压查看历史数据7八、工频接地阻抗的测量接地阻抗的测量可按下面的步骤进行。§8.1布置测试回路首先应根据现场的实际情况选择合适的测试回路布置。图4为现场通常采用的电流-电压表直线三极法的布置图,电压线和电流线之间的夹角为零。采用夹角法时,电压线和电流线之间的夹角不为零。直线法可视为夹角法的特例。辅助电流极应尽量远离被测接地装置,通常电流极与被测接地装置的距离应为被测接地装置最大对角线长度D的4倍以上。测试回路应尽量避开河流、湖泊;尽量远离地下金属管路和运行中的输电线路;注意减小电流线和电位线之间的互感影响,当采用直线法时,应注意使电压线和电流线保持尽量远的距离。现场条件允许时,大型地网接地阻抗的测试最好采用夹角法。一般情况下,可按下面的修正公式计算出接地装置的接地阻抗Z。]cosd2ddd1d1d1[2D1'ZZCGPG2CG2PGCGPG(8-1)式中,Z´=V/I为仪器测量值,D为被测接地装置最大对角线长度,dCG为电流极与接地装置边缘的距离,dPG为电位极与接地装置边缘的距离,θ为电流线与电位线的夹角。三极直线法可看作是θ=0时的特例。由上式可看出,若满足条件CGPGCGPG2CG2PG

1 / 14
下载文档,编辑使用

©2015-2020 m.777doc.com 三七文档.

备案号:鲁ICP备2024069028号-1 客服联系 QQ:2149211541

×
保存成功