1一.住宅电能表箱体尺寸标注标准序号电表箱型号箱体尺寸(WxHxC)表数安装方式备注11表箱MB1300x500x1601表箱暗装/明装22表箱MB2500x500x1602表箱暗装/明装33表箱MB3A650x500x1803表箱暗装/明装43表箱MB3B500x800x1803表箱暗装/明装54表箱MB4A500x800x1804表箱暗装/明装64表箱MB4B850x500x1804表箱暗装/明装75表箱MB5A650x800x1805表箱暗装/明装85表箱MB5B550x1000x1805表箱暗装/明装96表箱MB6A650x800x1806表箱暗装/明装106表箱MB6B550x1100x1806表箱暗装/明装118表箱MB8850x800x1808表箱暗装/明装129表箱MB8650x1100x1809表箱暗装/明装1312表箱MB12A650x1400x18012表箱暗装/明装1412表箱MB12B850x1100x18012表箱暗装/明装注:1以上参数选自华北标《低压配电装置》09BD3-31;2.箱体表面采用环氧树脂静电喷涂或烤漆,5.采用磁卡电度表时,箱面应留插卡孔;箱体采用1.2~1.5mm钢板制作;3.本箱体进线断路器为63A,进线截面不大于25mm2;4.墙体留洞尺寸为箱体尺寸加10mm;二.86系列电能表技术参数名称型号精度额定电流(A)额定电压(V)外型尺寸(mm)接线单相有功电能表DD86225100200220240124x207x118互感器DD862-41.5,2.5,3,5,10,15,20,30,直接接入DD862-610(20),10(40),15(60,)20(80)三相有功电能表DT86221.5(6),3(6)380220172x279x124互感器DT862-45.10.15.20.30直接接入DT862-610(60),30(90)三相无功电能表DS86223(6)100380172x279x124互感器DS862-41.5(8),5(20),10(40)直接接入DS862-61(6)互感器1.以上参数选自华北标《低压配电装置》09BD3-49;2.预付费表一般采用DDY型号,厂家不同而不同;参数参考DD862-6系列;2三.住宅户内照明配电箱尺寸参数序号明装嵌入暗装箱体尺寸(WxHxC)出线回路单极断路器数量1LB11LBR11250x250x1203~62LB12LBR12350x250x1207~103LB13LBR13450x250x12011~154LB14LBR14550x250x12016~215LB15LBR15600x250x12022~266LB16LBR16750x250x12027~331.以上参数选自华北标《低压配电装置》09BD3-57;2.墙体留洞尺寸为箱体尺寸加10mm;3.分路断路器每极宽度为18mm;四.普通照明配电箱尺寸参数序号明装嵌入暗装箱体尺寸(WxHxC)进线断路器小于A出线回路单极短路器数量1LB21LBR21300x500x120639~152LB22LBR22400x500x1206316~243LB23LBR23460x500x1206325~334LB24LBR24560x500x1206334~405LB25LBR25660x500x1206341~506LB31LBR31600x500x120250247LB32LBR32700x500x120250308LB33LBR33800x500x120250369LB34LBR34100x500x1202504610LB35LBR351200x500x120250581.以上参数选自华北标《低压配电装置》09BD3-59.61;2.箱体采用1.2~1.5mm电解钢板或冷轧钢板制作;3.箱体表面采用环氧树脂静电喷涂或烤漆,不注明一般为浅灰色。4.本箱体进线断路器为63A,进线截面不大于25mm2;5.分路断路器每极宽度为18mm;6.墙体留洞尺寸为箱体尺寸加10mm;3五.动力配电箱尺寸参数序号嵌入暗装明装箱体尺寸(WxHxC)元器件备注1PBR11300x500x1802PBR12400x600x2003PBR13500x800x2004PBR14600x1000x2205PBR15800x1000x2206PBR16800x1200x2507PB11300x500x1808PB12400x600x2009PB13500x800x20010PB14600x1000x22011PB15800x1000x22012PB16800x1200x2501.以上参数选自华北标《低压配电装置》09BD3-63.64。2.箱体采用1.2~1.5mm电解钢板或冷轧钢板制作;3.箱体表面采用环氧树脂静电喷涂或烤漆,不注明一般为浅灰色。4.墙体留洞尺寸为箱体尺寸加10mm;5.PC级双电源带分支配电开关箱尺寸:600X800X200六.动力配电柜参数序号型号断路器等级(A)箱体尺寸(WxHxC)进线断路器不大于分断路器不大于1PB8011630600x1600x400630A315A2PB8012630600x1800x400630A315A3PB8013630800x1800x400630A315A4PB8014630600x2200x600630A315A5PB8015630800x2200x600630A315A6PB8021630600x1600x400630A315A7PB8022630600x1800x400630A315A8PB8023630800x1800x400630A315A9PB8024630600x2200x600630A315A10PB8025630800x2200x600630A315A11PB8026630900x2200x600630A315A12PB8027630900x2200x600630A315A1.以上参数选自华北标《低压配电装置》09BD3-63.64。2.PB801柜为高层住宅落地式动力配电柜,柜前检修,可靠墙安装;3.柜体采用不小于2mm冷轧钢板制作;柜体表面采用环氧树脂静电喷涂4七.常用变配电室低压配电柜参数型号额定电压(V)额定电流(A)额定短路开断电流(KA)额定短时耐受电流(KA)额定峰值耐受电流(KA)柜体尺寸固定式低压柜GGD1380A1000151530800(1000)X600x2200B600(630)C400固定式低压柜GGD2380A1500(1600)303063800(1000)X600x2200B1000C固定式低压柜GGD3380A31505050103800(1000)X600(8020)x2200B2500C2000抽出式低压柜GCK380660水平母线630~31505050105600(800,1000)x1000x2200垂直母线400~1000抽出式低压柜GCS380660水平母线40005050105600(400,800,1000)x1000(800,600)x2200垂直母线10005050105抽出式低压柜SE-MNS380690水平母线6300100220220800(400,600,1000,1200)x800(600,1000,1200)x2200垂直母线1200~2000651102201.以上参数选自华北标《低压配电装置》09BD3-97~151