青岛工学院毕业论文(设计)××结构设计学生姓名学号指导教师学院专业年级答辩日期青岛工学院××结构设计完成日期:指导教师签字:评阅教师签字:答辩小组组长签字:答辩小组成员签字:I摘要本工程位于山东省青岛市,为现浇钢筋混凝土框架结构,总建筑面积为33352m。本工程共四层,首层层高3.6m,其他层高3.3m,建筑总高度为13.5m。根据设计要求,设防烈度为6度,耐火等级为二级,抗震等级为三级,设计中要考虑抗震设计。结构设计由框架设计,梁柱设计,板设计和基础设计等组成。本工程选择中间一榀横向框架进行计算设计,内力计算时考虑竖向荷载、水平风荷载以及地震作用,对于竖向荷载作用采用的是二次弯矩分配法,水平荷载采用D值法,地震作用采用底部剪力法。基础采用钢筋混凝土独立基础。关键词:框架结构;现浇混凝土;结构设计;抗震设计IIAbstractTheprojectislocatedinqingdaocity,ShandongProvince.Anditistheconstructionofcast-in-situreinforcedconcreteframestructure.Thewholearchitectureareais3335m².Theengineeringhasfourfloors.Thefirstlayeris3.6mandtheotherlayeris3.3m.Thetotalbuildingheightis13.5m.Accordingtothedesignrequirements,fortificationintensityof6degrees,fireresistanceratingforthesecondary,earthquakeresistantlevelforlevel3,wanttoconsiderinthedesignofseismicdesign.Structuraldesignisconsistedbydesignofframe,beamandcolumndesign,boarddesignandthefoundationdesignetc.Thisprojectchoosethemiddleonecommonhorizontalframeworkfordesigncalculation.Theinternalforcecalculationshouldconsiderverticalload,horizontalwindloadandseismicaction.Verticalloadfunctionadoptsquadraticmomentdistributionmethod,levelloadfunctionadoptsDvaluemethod,andseismicloadfunctionadoptsequivalentbaseshearmethod.Basisusereinforcedconcreteindependentfoundation.Keywords:framestructure;cast-in-situconcrete;structuredesign;seismicdesignIII目录1工程概况...........................................................12板的设计...........................................................32.1板的设计.......................................................32.2框架结构布置及计算简图.........................................72.2.1梁柱的截面尺寸.............................................72.2.2梁柱线刚度.................................................83竖向荷载下的内力计算.............................................93.1恒荷载的计算...................................................93.2恒荷载作用下内力计算..........................................123.3活荷载内力计算................................................213.3.1荷载标准值计算............................................213.3.2活荷载作用下内力计算......................................224水平荷载作用下框架内力分析.....................................294.1层间侧刚度计算................................................294.1.1线刚度计算................................................294.1.2梁的线刚度计算............................................294.1.3柱的侧移刚度计算D.........................................314.2地震作用下框架内力分析........................................324.2.1各层重力荷载代表值计算....................................324.2.2结构自振周期..............................................334.2.3水平地震作用及框架侧移验算计算............................344.2.4地震荷载作用下的内力计算..................................364.2.5水平地震荷载内力图........................................464.3风荷载计算....................................................485框架结构的内力组合..............................................555.1框架梁内力组合................................................555.2框架柱内力组合................................................626截面设计..........................................................676.1框架梁的截面设计..............................................676.2框架柱的截面设计..............................................747基础设计..........................................................767.1选择基础材料..................................................767.2初步选择基底尺寸..............................................77IV7.3基础结构设计..................................................79致谢.................................................................84附表1柱正截面配筋表..............................................85附表2柱斜截面配筋表..............................................87××结构设计11工程概况设计题目:山东省青岛市第一人民医院病房楼结构设计设计标高:室内设计标高000.0±,屋面板顶面标高为14.00m,室内外高差为600mm,1.2m女儿墙高度]1[。屋面做法:(1)刚性防水层:40厚C20防水细石混凝土;(2)隔离层(干铺玻纤布或低强度等级砂浆)一道0.1厚;(3)防水层:a.1.2厚合成高分子防水卷材;(4)找平层:20厚1:3水泥砂浆找平;(5)保温层:40厚(最薄处)1:8(重量比)水泥珍珠岩找坡层2%;(6)钢筋混凝土屋面板楼面做法:(1)15厚水磨石面层;(2)20厚1:3水泥砂浆找平层;(3)1.5厚合成高分子防水涂料防水层;(4)20厚1:3水泥砂浆抹平;(5)60厚LC7.5轻骨料混凝土填充层并找坡;(6)现浇钢筋混凝土楼板活荷载:均布活荷载标准值0.52/kNm(不上人屋面),楼面活荷载为2.02/kNm,雪荷载标准值为0.22/kNm。抗震要求:地震设防烈度为6度,设计基本地震加速度值为0.05g;设计地震分组为第二组,建筑场地类别为II类,场地地震周期为0.35s。设计材料:混凝土采用C30,钢筋混凝土框架梁、柱等主要结构构件的纵向受力钢筋采用HRB400,构造钢筋及箍筋可采用HPB335,对于钢筋混凝土板、墙等构件的受力钢筋及构造钢筋采用HPB335。基本风压:0.62/kNm(地面粗糙度属于B类)门窗做法:门厅处为铝合金门窗,其余均为木门、钢窗。屋盖设计。××结构设计2××结构设计32板的设计2.1板的设计1、板的设计屋面活荷载与雪荷载不同时考虑,两者取较大值。(屋盖)不上人屋面找平层:40mm厚1:3水泥砂浆找平280kN/m.0040.020防水层:(刚性)40厚C20细石混凝土20kN/m.1防水层:(柔性)1.2mm厚合成高分子防水卷2kN/m170.00012.041保温找坡层:40mm厚水泥珍珠盐找坡2%240kN/m.0040.010结构层:150mm厚现浇混凝土板2m/kN75.351.025合计2.97kN/m5楼面楼面层:15mm厚水磨石面层2m/kN30.0015.020找平层:20mm厚1:3水泥砂浆2m/kN40.002.020防水层:1.5mm厚合成高分子防水卷材21kN/m20.00015.041找平层:20mm厚1:3水泥砂浆2m/kN40.002.020填充层:60mm厚轻骨料填充并找坡2m/kN60.006.010结构层:150mm厚现浇混凝土板2kN/m75.351.025合计5.472kN/m则屋面板的恒载2/97.5mkNgk屋盖,2/16.72.197.5mkNg屋盖活载××结构设计42/0.5mkNqk屋面2/0.74.10.5mkNqk屋面楼面的恒载2/47.5mkNgk楼面,2/56.62.147.5mkNgk楼面活载2/2mkNqk楼面,2/8.24.12mkNqk楼面板传荷载示意图及板分割示意图分别如下图所示。弯矩计算××结构设计5楼面板和屋面板的计算过程见表2-1和表2-2。表2-1屋面板弯矩值计算表AB01lm3.852.402lm7.03.850201/ll0.550.621m(0.039+0.2×0.006)×6.05×3.852+(0.089+0.2×0.021)×0.35×3.852=4.09=3.988(0.036+0.2×0.008)×6.05×2.42+(0.079+0.2×0.02