国家电网公司集中规模招标采购(项目单位)35kV(工程名称)35kV电力电缆招标文件(技术规范专用部分)设计单位:2011年XX月2目录1技术参数和性能要求·····································································································11.126/35kV电缆结构及技术参数····················································································11.2电缆非电气技术参数·······························································································12项目需求部分··············································································································62.1货物需求及供货范围一览表······················································································62.2必备的备品备件、专用工具和仪器仪表供货表······························································62.3投标人应提供的有关资料·························································································72.4工程概况···············································································································72.5使用条件···············································································································72.6项目单位技术差异表·······························································································83投标人响应部分···········································································································83.1技术偏差···············································································································83.2投标产品的销售及运行业绩表···················································································93.3主要原材料产地表··································································································93.4推荐的备品备件、专用工具和仪器仪表供货表······························································911技术参数和性能要求投标人应认真填写表1~表3中投标人保证值,不能空格,也不能以“响应”两字代替。不允许改动招标人要求值。如有偏差,请填写技术偏差表。1.126/35kV电缆结构及技术参数26/35kV电缆结构及技术参数见表1、表2。1.2电缆非电气技术参数电缆非电气技术参数见表3。表126/35kV电缆结构参数表序号项目单位标准参数值投标人保证值备注1电缆型号2铜导体材料铜(投标人填写)材料生产厂及牌号(投标人提供)(投标人填写)芯数×标称截面积芯×mm23×185(投标人填写)3×240(投标人填写)3×300(投标人填写)3×400(投标人填写)3×500(投标人填写)1×630(投标人填写)结构形式圆形紧压(投标人填写)最少单线根数根30(投标人填写)对应185截面34(投标人填写)对应240截面34(投标人填写)对应300截面53(投标人填写)对应400截面53(投标人填写)对应500截面53(投标人填写)对应630截面单线直径mm(项目单位填写)(投标人填写)对应185截面(项目单位填写)(投标人填写)对应240截面(项目单位填写)(投标人填写)对应300截面(项目单位填写)(投标人填写)对应400截面(项目单位填写)(投标人填写)对应500截面(项目单位填写)(投标人填写)对应630截面导体外径mm(项目单位填写)(投标人填写)对应185截面(项目单位填写)(投标人填写)对应240截面(项目单位填写)(投标人填写)对应300截面(项目单位填写)(投标人填写)对应400截面2表1(续)序号项目单位标准参数值投标人保证值备注2铜导体导体外径mm(项目单位填写)(投标人填写)对应500截面(项目单位填写)(投标人填写)对应630截面紧压系数≥0.9(投标人填写)3铝导体材料铝(投标人填写)材料生产厂及牌号(投标人提供)(投标人填写)芯数×标称截面积芯×mm23×150(投标人填写)3×240(投标人填写)3×300(投标人填写)3×400(投标人填写)结构形式圆形紧压(投标人填写)最少单线根数根15(投标人填写)对应150截面30(投标人填写)对应240截面30(投标人填写)对应300截面53(投标人填写)对应400截面单线直径mm(项目单位填写)(投标人填写)对应150截面(项目单位填写)(投标人填写)对应240截面(项目单位填写)(投标人填写)对应300截面(项目单位填写)(投标人填写)对应400截面导体外径mm(项目单位填写)(投标人填写)对应150截面(项目单位填写)(投标人填写)对应240截面(项目单位填写)(投标人填写)对应300截面(项目单位填写)(投标人填写)对应400截面(项目单位填写)(投标人填写)(项目单位填写)(投标人填写)紧压系数≥0.9(投标人填写)4挤包导体屏蔽层材料、生产厂及牌号半导电料(投标人填写)平均厚度mm0.8(投标人填写)最小厚度mm0.7(投标人填写)外径mm(投标人填写)5绝缘材料、生产厂及牌号XLPE(投标人填写)平均厚度不小于标称厚度tmm10.5(投标人填写)3表1(续)序号项目单位标准参数值投标人保证值备注5绝缘最薄点厚度不小于mm9.7(投标人填写)偏心度%8(投标人填写)6挤包绝缘屏蔽层标称厚度mm0.8(投标人填写)最小厚度mm0.8(投标人填写)外径mm(项目单位填写)(投标人填写)7金属屏蔽铜带层数1(投标人填写)铜带厚度mm0.15(投标人填写)搭盖率不小于%20(投标人填写)20℃时最大直流电阻Ω/km(项目单位填写)(投标人填写)8填充层填充材料非吸湿性聚丙烯撕裂薄膜(投标人填写)9隔离套挤包材料(项目单位填写)(投标人填写)最小厚度不小于mm80%t(投标人填写)10内衬层材料(项目单位填写)(投标人填写)厚度mm(项目单位填写)(投标人填写)11铠装层材料镀锌钢带(投标人填写)厚度mm0.8(投标人填写)仅适用于三芯电缆层数层2(投标人填写)宽度mm(项目单位填写)(投标人填写)12外护套材料PVC(投标人填写)材料生产厂及牌号(项目单位填写)(投标人填写)颜色黑色/红色(投标人填写)标称厚度tmm4.2(投标人填写)对应150截面4.4(投标人填写)对应185截面4.5(投标人填写)对应240截面4.6(投标人填写)对应300截面4.9(投标人填写)对应400截面2.7(投标人填写)对应500截面2.9(投标人填写)对应630截面最薄点厚度不小于mm90%t(投标人填写)13电缆外径Dmm(项目单位填写)(投标人填写)(投标人填写)4表226/35kV电缆电气技术参数表序号项目单位标准参数值投标人保证值备注120℃时铜导体最大直流电阻Ω/km0.0991(投标人填写)对应185截面0.0754(投标人填写)对应240截面0.0601(投标人填写)对应300截面0.0470(投标人填写)对应400截面0.0366(投标人填写)对应500截面0.0283(投标人填写)对应630截面220℃时铝导体最大直流电阻Ω/km0.0206(投标人填写)对应150截面0.1250(投标人填写)对应240截面0.1000(投标人填写)对应300截面0.0778(投标人填写)对应400截面390℃时铜导体最大交流电阻Ω/km(项目单位填写)(投标人填写)对应185截面(项目单位填写)(投标人填写)对应240截面(项目单位填写)(投标人填写)对应300截面(项目单位填写)(投标人填写)对应400截面(项目单位填写)(投标人填写)对应500截面(项目单位填写)(投标人填写)对应630截面490℃时铝导体最大交流电阻Ω/km(项目单位填写)(投标人填写)对应150截面(项目单位填写)(投标人填写)对应240截面(项目单位填写)(投标人填写)对应300截面(项目单位填写)(投标人填写)对应400截面5导体短路电流(250℃)kA/5s(项目单位填写)(投标人填写)6屏蔽短路电流kA/5s(项目单位提供)(投标人填写)7电缆电容值μF/km(项目单位填写)(投标人填写)8电缆电感值μH/km(项目单位填写)(投标人填写)9电缆长期允许载流量A(项目单位填写)(投标人填写)10导体温度℃90(投标人填写)正常运行时最高允许温度250(投标人填写)短路时最高允许温度11局部放电(试验灵敏度10pC或更优,35kV下)pC无可检测放电(投标人填写)12雷电冲击试验(导体温度95℃~100℃下)kV/次±200/各10(投标人填写)13tanδ(导体温度95℃~100℃下)≤8×10-4(投标人填写)14导体屏蔽层老化前后90℃时电阻率Ω·m≤1000(投标人填写)15绝缘屏蔽层老化前后90℃时电阻率Ω·m≤500(投标人填写)5表2(续)序号项目单位标准参数值投标人保证值备注16出厂工频电压试验kV/min91/5(投标人填写)17安装后工频电压试验kV/min35/5(投标人填写)18电缆盘尺寸mm(项目单位填写)(投标人填写)19电缆敷设时的最小弯曲半径m10D(投标人填写)20电缆运行时的最小弯曲半径m(项目单位填写)(投标人填写)21电缆敷设时的最大牵引力N/mm270(投标人填写)铜芯,牵引头40(投标人填写)铝芯,牵引头22电缆敷设时的最大侧压力N/m(项目单位填写)(投标人填写)23电缆质量kg/m(项目单位填写)(投标人填写)24电缆敷设时允许环境温度℃(项目单位填写)(投标人填写)25电缆在正常使用条件下的寿命年≥30(投标人填写)26最大卤素含量(低毒电缆)mg/g(项目单位填写)(投标人填写)(采用阻燃电缆时填写)27最大烟密度(低烟)(项目单位填写)(投标人填写)(采用阻燃电缆时填写)28电缆阻燃级别(项目单位填写)(投标人填写)(采用阻燃电缆时填写)表3电缆非电气技术参数表序号项目单位标准参数值投标人保证值备注1绝缘老化前抗张强度不小于MPa12.5(投标人填写)老化前断裂伸长率不小于%200(投标人填写)老化后抗张强度变化率不超过%±25(