合肥供电公司配变监测系统通讯规约合肥供电公司发布目录通讯规约.....................................................................................................I1概述.......................................................................................................12术语.......................................................................................................22.1主站masterstation.........................................................................................22.2前置机frontendprocessor.............................................................................22.3客户现场终端fieldagent...............................................................................32.4应用层applicationlayer.................................................................................32.5通讯接口层communication-interfacelayer..................................................32.6配变监测应用层协议......................................................................................32.7标准报文standardpacket...............................................................................32.8非标准报文nonstandardpacket.....................................................................32.9测量点measuredpoint...................................................................................32.10中继命令forwardcommand..........................................................................42.11任务scheduledtask........................................................................................42.12中继任务forwardtask...................................................................................43通讯规约...............................................................................................43.1协议层次描述..................................................................................................43.2加密压缩帧格式..............................................................错误!未定义书签。3.3应用层(LMAL)..........................................................................................53.3.1帧格式...............................................................................................................53.4通讯接口层....................................................................................................263.5终端校时........................................................................................................284附录.....................................................................................................294.1数据项编码与格式........................................................................................294.2错误编码........................................................................................................464.3告警编码........................................................................................................464.4供电电压编码................................................................................................484.5任务描述........................................................................................................484.6对于规约必须实现部分和可选部分的规定................................................514.7异常告警的默认参数配置............................................................................524.8多套功率曲线说明........................................................................................554.9针对技术条件的实现举例............................................................................56合肥供电公司配变监测系统通讯规约版本:1.0合肥供电公司第1页1概述本规约规定了配变监测系统终端与前置机、厂商分析程序、应用服务器的通讯规约。本规约适用于配变监测系统。本规约参考了DL-535-96《电力负荷控制系统数据传输规约》,DL/T645-1997《多功能电能表通信规约》。考虑到应用的特殊性和支持多种通讯方式,特别是新出现的GPRS、短信等方式(没有对应的标准规约可以参照),所以规定了本通讯规约。配变监测系统的整体构架如下图所示:厂商A解码分析包LMALSMS现场应用服务信息调度前置机通讯服务CNCGPRS............FAALDB前置机数据库服务器对外通讯部分厂商解码分析部分厂商N解码分析包厂商B解码分析包FAoverSMSFAoverTCP/UDPFASIS应用服务器终端终端主体部分终端通讯部分MLALFAoverxxx合肥供电公司配变监测系统通讯规约版本:1.0合肥供电公司第2页如上图所示,系统由应用服务器、数据库服务器、前置机和终端组成,其中应用服务器、数据库服务器和前置机构成了主站;前置机由对外通讯部分、厂家解析分析部分与前置机通讯服务程序组成。对于上行信息,通过前置机的对外通讯部分接收后,进行通讯层的解码,得到规约的应用层报文,然后根据应用层报文的类型作如下处理:标准报文交给主站现场应用服务程序进行解释处理,同时传送给厂商解码分析程序;非标准报文按照不同的厂商提交相应的厂商解码分析程序。厂商解码分析程序可以以上行报文的形式将分析结果按照标准报文格式送给前置机通讯服务程序,通讯服务收到后转发给应用服务器;厂商解码分析程序也可以以下行报文的形式将召测命令发送给前置机通讯服务程序,通讯服务程序收到后转发给终端。由应用服务器发起的通讯一律通过标准报文下发。在本规定中,已对具体帧结构中的数据传输顺序表述的,以该表述顺序传输;对于数据项字节数≥2的,以低字节在前高字节在后的顺序传输。2术语2.1主站masterstation具有选择终端并与终端进行信息交换功能的设备。在配变监测系统中,主站包括前置机、应用服务器和数据库服务器三个部分,而前置机则是直接和终端进行通讯的部分。2.2前置机frontendprocessor负责通过各种通讯介质和终端进行通讯的前置设备,并能在与主站其它部分脱离联系后(通讯部分还正常),维持系统运行的设备。合肥供电公司配变监测系统通讯规约版本:1.0合肥供电公司第3页2.3终端Teminal安装于配变的用于配变数据采集和工况监控的设备,简称终端。2.4应用层applicationlayer独立于通讯层的,在主站和终端之间传输信息的协议部分。2.5通讯接口层communication-interfacelayer规定了应用层协议如何在不同的下层通讯协议上实现。2.6配变监测应用层协议独立于通讯层的,在配变监测系统主站内部之间以及主站与终端之间传输信息的协议2.7标准报文standardpacket指本规约的应用层规约制定的非用户自定义部分的报文2.8非标准报文nonstandardpacket指本规约的应用层规约制定的用户自定义部分的报文2.9测量点measuredpoint指采用某种装置可以在一个特定的时间点测量出唯一的一组量值的电气连接点,这组量值以某种方式被传递到终端。当物理上相同的一个电气连接点被多个装置所测量,或者被一个装置所测量但通过多种方式被传递到终端时,按照多个测量点计。合肥供电公司配变监测系统通讯规约版本:1.0合肥供电公司第4页2.10中继命令forwardcommand终端将收到的中继命令中的命令内容不做任何解释发给下属设备,然后将下属设备返回的结果不加任何解释封装到中继命令返回结构中的数据域。2.11任务scheduledtask规定终端在指定时间或条件下所需执行的操作。2.12中继任务forwardtask规定终端在指定时间执行的中继命令,命令在任务中指定,结果由终端保存后返回到主站。3通讯规约3.1协议层次描述本规约主要详细描述了应用层的协议,该应用层协议可以基于多种不同的下层协