8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00瑞士哈美顿伽利略呼吸机产品培训8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00伽利略呼吸机整体8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00空气压缩机电源及开关压力表接中心供气端(提供后备空气源)呼吸机空气源端过滤网(定期清水清洗)8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00空压机指示表当指针指向绿色区域为正常使用状态如指针在红色或黄色区域,需联系维修工程师8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00正确连接配件(接MR810湿化器)8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00正确连接配件(接MR850湿化器)8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00正确连接流量传感器•呼吸机端:蓝管接蓝色端口,透明管接白色端口。•病人端:蓝色管朝向病人,透明管远离病人复用型细菌过滤器可用高压蒸汽灭菌法,124℃,10分钟8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00传感器技术—近心端流量传感器•管道顺应性自动补偿•密闭性测试通过后,可定位漏气部位为传感器到病人端•死腔量小,可用于低体重新生儿,其他同类产品只有在新生儿功能才选配近心端流量传感器•测量灵敏度和精确度高,用于闭环通气•使用中失效的话,呼吸机采用远心端内置传感器测量•减少误触发,减低病人呼吸做功8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00近心端流量传感器的使用1.正确连接2.连接病人前需做流量传感器校准,2次校准不能通过,请更换新的传感器3.测压管维持向上的方向4.维持病人端稍微高于呼吸机端,以便冷凝水排到积水杯5.如遇病人痰液,血液喷出到流量传感器,发现后立即取下,用清水或1:300多酶浸泡后清洗干净待用6.消毒:清水清洗后,用2%戊二醛浸泡传感器端+10公分测压管10分钟,反复无菌蒸馏水清洗干净,晾干待用7.连接病人时如出现”流量传感器”需校准的信息,一般是由冷凝水聚集造成,清除冷凝水即可8.如处理后信息仍存在,更换新的传感器,测试通过后连接病人,期间用复苏气囊维持病人通气8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00呼气阀盖及阀膜金属片朝上方阀盖阀膜可用2%戊二醛浸泡15分钟,或高压蒸汽灭菌124℃、10分钟,或环氧乙烷气体消毒8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00湿化装置1.使用中无需安装铝轴,或将湿化纸卷入铝轴中再用。湿化纸每个病人更换一张。2.MR810尽量保持用3档3.无菌蒸馏水加到警戒线4.清洗前需将湿化罐各部件全部拆开,包括各种接头,用清水清洗干净。5.然后可用2%戊二醛浸泡15分钟,反复蒸馏水清洗干净,晾干待用6.或高压蒸汽灭菌124℃、10分钟,或环氧乙烷气体消毒MR810MR850MR370成人儿童通用湿化罐MR340儿童新生儿通用湿化罐8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00伽利略呼吸机背面1.医用顶盘2.风扇滤膜(定期清水清洗)3.高压空气进口4.高压氧气进口5.配有过滤器的高压气体积水杯6.序列号标签7.通讯接口8.泄压口9.电源开关10.电源线及固定夹11.保险丝盒12.电源插座13.电压均衡点(接地)导线端子8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00伽利略呼吸机背面空气端积水杯需定期排放水氧气端积水杯需定期排放水8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00伽利略前面板11.显示屏2.监测按钮3.控制按钮4.报警静音键5.100%氧气键6.手动通气键7.雾化功能键8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00伽利略前面板21.Paux接口2.雾化器接口3.流速传感器接口4.通向病人的端口5.吸气过滤器6.氧电池托架7.排气口8.呼气阀盖和膜9.来自病人的端口8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00开机选择成人儿童新生儿选择上次设置8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00上机前务必完成2项测试1.进入模式菜单2.选择Calibration3.如图选择流量传感器校准和密闭性测试4.更换新管道后必须完成这两项测试8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00面板显示模式主要参数设置报警设置病人类型8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00选择适合病人病情的呼吸机模式8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00报警设置初始上机可选择Auto,待病人稳定后再做微调8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00雾化器正确连接雾化器连接吸气端注意事项•呼气阀盖和膜与管道一期常规清洗消毒;•请勿接呼气端过滤器;•请勿接HME;•如使用MR850湿化器,则雾化装置接在温度探头与Y管之间;•雾化停止后要及时取下雾化装置8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00雾化进行•按下该键即开启雾化,能持续雾30min•未满30min按下该键关闭雾化8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00伽利略一览1.模式齐全2.智能化设计—ASV闭环通气3.P/V工具4.辅助压力监测5.完善的病人监测6.近心端流量传感器及TRC7.内置一体式雾化功能8.中文菜单9.可追溯的事件日志8.157.158.305.508.0011.706.405.700.450.305.906.4011.709.009.007.00伽利略–性能超群的智能呼吸机