1DatacolorTOOLS使用手册目录1.运行DatacolorTOOLS...................................................................................................22.仪器设定与校正...............................................................................................................23.测量和输入样品...............................................................................................................53.1.测量标准样............................................................................................................53.2.测量批次样............................................................................................................63.3.标准样或批次样的输入..........................................................................................74.标准样和批次样默认值设定.............................................................................................84.1.标准样默认值设定.................................................................................................84.2.批次样默认值设定.................................................................................................95.标准样和批次样的保存与取出.........................................................................................95.1.标准样的保存与取出.............................................................................................95.2.批次样的保存与取出...........................................................................................116.桌面数据管理.................................................................................................................126.1.桌面选项.............................................................................................................136.2.标准样选项..........................................................................................................136.3.批次样选项..........................................................................................................147.光源设定........................................................................................................................148.编辑允差........................................................................................................................158.1.编辑允差.............................................................................................................158.2.新增允差.............................................................................................................168.3.允差选择.............................................................................................................179.编辑主菜单按钮.............................................................................................................1810.屏幕模板设置与保存....................................................................................................1910.1数据栏设置.........................................................................................................1910.2绘图栏设置.........................................................................................................2010.3色块栏设置.........................................................................................................2110.4屏幕模板保存.....................................................................................................211.运行DatacolorTOOLS21.1.双击桌面DatacolorTOOLS/DatacolorTOOLSPlus图标1.2.出现如下登录界面1.3.键入用户名纺织版本用户:dci颜料版本用户:user原始密码为空白1.4.点击‘确定’,运行TOOLS程序2.仪器设定与校正2.1.在工具栏中点选仪器-校正2.2.弹出测色主视窗窗口,点选‘校正’,在校正条件窗口选择所需要的仪器设定3镜面光泽:测色时镜面光泽的设定测色孔径:选择测色孔径自动调整:勾选自动调整选项,仪器可自动判别当前孔径UV滤镜:测色时UV含量的选定100%UV:包含UV,即不使用UV滤镜0%UV:不包含UV,即使用UV滤镜滤去400nm以下的发射光谱FL42滤镜:滤去420nm以下的发射光谱FL46滤镜:滤去460nm以下的发射光谱UVGanz-GriesserCalibration:通过Ganz-Griesser校正后用其指定位置的UV滤镜,用于测量Ganz-Griesser白度UVCIEWhitenessD65/10:通过ISO11475校正后用其指定位置的UV滤镜,用于测量CIE白度UVCIEWhitenessC/2:通过ISO2470校正后用其指定位置的UV滤镜,用于测量CIE白度校正器:使用自定义的UV滤镜位置测量标准白板:输入仪器的标准白板值校正间隔时间:同一设定条件下的校正间隔时间42.3.设定完成后,点击‘校正’,即开始仪器校正程序2.4.弹出放置黑筒的提示,正确放置黑筒(字体向上)并点击‘继续’2.5.黑筒校正完后,弹出放置白色校正板的提示,将黑筒取下,放置白色校正板,点击‘继续’52.6.白板校正完后,弹出放置绿色诊断板的提示,将白板取下更换绿色诊断板,点击‘继续’2.7.绿板校正完后,出现下列窗口,点击‘确定’,完成校正程序3.测量和输入样品3.1.测量标准样3.1.1.在主菜单下点击‘标准样’图标3.1.2.进入测色主视窗,根据需要选择单次测色或多次测色6以多次测色为例,点击‘测色’,即开始测量动作,如需要再次测量色样,按需要移动色样位置后,再点击‘测色’,如不需要再测量,则点击‘接受目前资料’结束测量。若达到默认测量次数时,‘测色’按钮会变成‘接受’按钮,点击即可结束测量。3.2.测量批次样3.2.1.在主菜单下点击‘批次样’图标3.2.2.进入测色主视窗(如3.1.2.所示),按相同操作测量批次样3.3.标准样或批次样的输入7除了仪器测量外,还可以在主菜单中点选标准样或批次样的下拉箭头选择样品的其他输入方式仪器:单点测色仪器平均值:多点测色标准样文件:取出标准样历程记录文件:取出批次样%R16点:输入16点反射率数据%R31点:输入31点反射率数据%T16点:输入16点穿透率数据%T31点:输入31点穿透率数据Lab:输入Lab数据LCh:输入LCh数据Luv:输入Luv数据HunterLab:输入HunterLab的Lab数据XYZ:输入CIEXYZ数据%RIR:输入包含红外区域(710nm-1100nm)的反射率数据平均批次样:取当前所有批次样的平均值作为一个新的标准样或批次样遮盖率/不透明度/浊度:测量遮盖率选择了输入方式后,点击主菜单下的‘标准样’或‘批次样’图标即可生效84.标准样和批次样默认值设定4.1.标准样默认值设定4.1.1.点选标准样-标样默认4.1.2.弹出标准样默认值窗口设置标准样的保存方法、输入方法和命名方法,确定后,在点击主菜单下的‘标准样’图标(如3.1.1所示)即可生效。4.2.批次样默认值设定94.2.1.点选批次样-批样默认值4.2.2.弹出批次样默认值窗口设置批次样的保存方法、输入方法和命名方法,确定后,在点击主菜单下的‘批次样’图标(如3.2.1)即可生效。5.标准样和批次样的保存与取出5.1.标准样的保存与取出5.1.1.标准样的保存点选标准样-保存当前标样10弹出选择文件夹窗口选择要保存标样的文件夹,然后确定,则把标样数据保存至数据库中。也可以右键选择新建文件夹,然后确定保存。5.1.2.标准样的取出点选标准样-取得标样,即取出曾经保存过的标样。点选标准样-取出色样,即取出任何曾经保存过的样品作为标样。115.2.批次样的保存与取出5.2.1.批次样的保存点选批次样-保存批样,即保存当前批样。点选批次样-保存全部批样,即保存当前标样下的所有批样。点选批次样-保存为标样,即