©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential1Nexus7K-5K-2K配置介绍——VDC、FEX、VPC思科系统©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential2提纲Nexus系列设备简介VDC技术与配置FEX技术与配置VPC技术与配置©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential3LAN/SANLAN思科数据中心Nexus系列交换机概览Nexus7000Nexus1000VNexus1010Nexus5000Nexus2000Nexus3000Nexus4000CiscoNX-OS:OneOSfromtheHypervisortotheDataCenterCoreConvergenceVM-AwareNetworking10GbEswitchingFabricExtensibilityCloudMobilityScalabilityCiscoDCNM:SinglePaneofVisibilityforbothLANandSAN©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential4Nexus7010机框示意图前门(可选)前视图后视图系统状态指示灯集成线缆管理架引擎插槽(5-6)I/O卡插槽(1-4,7-10)进气口,可选过滤网排气口交换矩阵模块系统风扇组电源模块(最多3个)交换矩风扇组21RUFRU指示灯从前下方往后上方的空气流©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential5Nexus7018机箱示意图前门(可选)前视图后视图系统状态指示灯集成线缆管理引擎插槽(9-10)电源空气入口交换矩阵模块电源模块和空气出口(2-4)25RUFRU指示灯侧面气流板卡解锁按钮系统风扇组I/O板插槽(1-8,11-18)©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential6Nexus5548示意图©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential7Nexus5596示意图©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential8Nexus2248示意图©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential9VDC(VirtualDeviceContext)技术与配置©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential10Nexus7000VDC简介InfrastructureKernelVDC1VDC2VDC3GLBPVDC4Layer3ProtocolsOSPFBGPEIGRPGLBPHSRPIGMPPIMSNMP…VDC2Layer2ProtocolsVLANPVLANUDLDCDP802.1XSTPLACPCTS…VirtualDeviceContext一个物理设备上虚拟多个逻辑设备灵活的硬件资源分配软件功能以及故障隔离有效提高资源利用率安全独立的管理模式数据中心虚拟化Layer2ProtocolsLayer3ProtocolsVLANPVLANOSPFBGPEIGRPHSRPIGMPUDLDCDP802.1XSTPLACPPIMCTSSNMP……VDC1©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential11VDC类型DefaultVDC(VDC1)具有最高权限具有所有功能集以下配置只能在DefaultVDC进行•VDC的创建/删除/挂起;•资源的分配;•NX-OS软件升级;•EPLD升级;•Feature-set的安装(如FEXfeature);•CoPP;•Port-channel负载均衡模式Non-DefaultVDC(VDC2,3,4)具有所有的功能集在non-defaultVDC中的更改只影响该VDC本身VDC之间的协议进程均相互独立,互不干扰配置文件相互独立Checkpoint相互独立©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential12VDC资源类型只能在DefaultVDC中进行分配,且作用于所有VDC的资源,例如bootimage,CoPP等;共享资源分配给某个特定VDC,且由该VDC独占的资源,如物理端口、VLAN、路由表等;所有VDC共享的资源,如OOB管理口。独享资源全局资源©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential13可分配的独占资源包括Nexus7K(config-vdc)#limit-resourceu4route-memminimum96maximum96Nexus7K#shroutingmemoryestimateroute300000next-hops2Sharedmemoryestimates:Currentmax96MB;70179routeswith16nhsin-use1MB;9routeswith1nhs(average)Configuredmax96MB;70179routeswith16nhsEstimate87MB;300000routeswith2nhs8Mmemorycansupport20KIPv4routeswith4nexthops路由表分配以MB为单位©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential14物理端口分配原则Note:PortmodeforM132portmodule©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential15VDC创建和资源分配实例©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential16物理端口分配命令©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential17VDC配置——资源分配模板switch(config)#vdcresourcetemplateNexusswitchswitch(config-vdc-template)#limit-resourcevlanminimum32maximum256switch(config-vdc-template)#limit-resourcevrfminimum32maximum64switch(config-vdc-template)#exitswitch(config)#vdcengineeringtemplateNexusswitchswitch(config-vdc)#showvdcresourcetemplatetemplate::Nexusswitch--------ResourceMinMax--------------------vrf3264vlan32256template::default--------ResourceMinMax--------------------glbp_group04096port-channel0256span-ssn02vlan164094vrf168192switch(config-vdc)#©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential18VDC的配置保存保存单个VDC的配置在某个VDC下:copyrunning-configstartup-config保存所有VDC的配置DefaultVDC下:Copyrunning-configstartu-configvdcall©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential19二层资源使用情况MAC地址的学习©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential20三层资源的使用情况©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential21VDC的权限管理分配角色类型权限Network-AdminRead/WriteaccessforallVDCsVDC-AdminRead/WriteaccessforagivenVDCsNetwork-OperatorReadaccessforallVDCsVDC-OperatorReadaccessforagivenVDCsNewHireNetworkOperatorNetworkAdminVDCAdminRoleBasedAccessControl©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential22VDC之间的通信VDC之间不能通过背板进行通信所有通信都必须通过线卡上的实际物理连线,与独立物理设备间的通信相同©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential23带外管理使用mgmt0或者CMP(建议两者都是用)进行带外管理所有VDC均使用同一个物理mgmt0,每个VDC为mgmt0配置不同的IP地址,必须在同一个网段Mgmt0属于独立的VRF:management;其他数据端口属于defaultVRF©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential24FEX(FabricExtender)技术与配置©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential25FEX简介©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential26FEX术语FEX:扩展板卡(Nexus2000)ParentSwitch:作为虚拟交换机的控制引擎和交换矩阵(N5K/N7K)FabricLink:parentswitch与FEX的连接Fabricport:parentswitch上连接FEX的端口FEXUplink:FEX连接parentswitch的链路HostInterface(HIF):FEX下连主机的端口NetworkInterface(NIF):FEX接N5K/N7K的端口PhysicalviewLogicalviewHostInterfaceFEXUplinkParentSwitchFabricportsFabricPort-Channel©2009CiscoSystems,Inc.Allrightsreserved.CiscoConfidential27FEX工作机制作为N5K/N7K的一个远程板卡,不进行流量本地转发FEX的发现:SDP(SatelliteDiscoverProtocol)N5K/N7K检查软件兼容性,并对FEX进行升级;所有的配置都在N5K/N7K上进行,再推送到FEX带内管理模式HIF不运行STP在链路up时候HIF会发送BPDU,用于防环。一旦证明下面不是交换机之后就会停止发送BPDUHIF默认配置:PorttypeedgeBPDUguard