临时用电安全监理实施细则

整理文档很辛苦,赏杯茶钱您下走!

免费阅读已结束,点击下载阅读编辑剩下 ...

阅读已结束,您可以下载文档离线阅读编辑

资源描述

-1-目录1、临时用电工程特点及其技术、质量标准·····································-2-1.1编制依据·········································································-2-1.2专业工程特点···································································-2-2、监理工作范围及重点·····························································-3-2.1监理工作范围···································································-3-2.2监理工作重点···································································-3-3、监理工作流程······································································-3-4、监理工作控制要点、目标及手段··············································-3-4.1监理工作目标···································································-3-4.2监理工作控制要点·····························································-3-4.3临时用电监控手段····························································-12-5、临时用电监理工作方法和措施···············································-15-5.1临时用电的监理工作方法:················································-15-5.2安全监理的监理措施·························································-15-5.3临时用电通病及防治措施···················································-16-6、旁站具体部位及工序···························································-17--2-临时用电安全监理实施细则1、临时用电工程特点及其技术、质量标准1.1编制依据⑴某监理站监理规划⑵安全监理方案、临时用电施工方案⑶铁路工程基本作业施工安全技术规程(TB10301-2009)⑷铁路工程隧道工程施工安全技术规程(TB10302-2009)⑸铁路建设工程安全生产管理办法⑹建建[2009]389号铁路建设工程监理实施细则编制指南。1.2专业工程特点⑴施工现场用电临时性强、现场情况复杂多变。施工现场临时用电线路和负荷经常根据不同时期工程进度和机械设备用电量的变化而改移线路和撤消线路。现场施工作业工序繁多、不同工种轮番作业,工人流动性大;不同的工程所用的设备、机具各有不同,临时用电根据施工总平面图和施工场地的不同布局,有不同的布线方式。⑵临时用电负荷量大,动力机械设备多。本工程临时用电主要机械有混凝土搅拌机、混凝土输送泵、TBM等大功率机械,办公生活用电,用电负荷总量大,对临时用电线路要求高。⑶临时用电专业性强,对管理人员素质要求高。由于各类用电人员缺乏安全用电知识,触电事故时有发生,因此,对电工人员要求高,临时用电需要专业人员进行操作,需要专业人员对现场进行管理。⑷临时用电施工组织设计无针对性。由于施工场地复杂多变,容-3-易形成工地临时用电的随意性,施工前编制不专业、无针对性的施工组织设计,不能切实指导施工,造成现场操作不规范、管理混乱,从而导致触电事故。2、监理工作范围及重点2.1监理工作范围新建铁路兰州至重庆线西秦岭特长隧道工程(DK391+800~DK423+915)。2.2监理工作重点混凝土拌和站、隧道、桥梁、经理部、架子队驻地用电。3、监理工作流程临时用电监理工作流程见下页图。4、监理工作控制要点、目标及手段4.1监理工作目标通过安全监理,督促施工单位以安全方式安全用电,确保安全防护措施到位。追求最大限度不发生安全事故,确保安全生产。4.2监理工作控制要点⑴审查施工单位编制的临时用电方案。⑵对施工现场电工及用电人员进行检查。①电工作业人员应持有相关部门培训合格,特种作业人员持证上岗;②施工现场临时用电施工,是否符合临时用电施工组织设计和安全操作规程;-4-不符合要求否情况严重的是拒不不停止施工否是临时用电监理工作流程施工单位申报临时用电施工组织设计监理审查临时用电施工组织设计计计审查施工单位电工上岗证定期组织安全检查发现安全隐患发《监理工程师通知单》要求施工单位整改监理检查验收发《工程暂停令》及时向建设单位报告施工方暂停施工及时向建设单位报告施工方进行整改及时报告建设单位整改是否符合要求同意继续施工或同意复工整理资料归档同意上岗不定期抽查特种作业人员持证上岗情况是否符合要求整改-5-③检查临时安全教育培训情况及考核情况;④检查临时用电技术交底签认记录;⑶定期对施工现场临时用电进行检查。基本情况检查:①施工用电应采用电源中性点直接接地的380/220V三相五线制低压电力系统,并必须符合下列规定:采用三级配电系统;采用TN-S接零保护系统;采用二级保护系统。②当采用10kV及以上高压电力系统时,应执行《铁路隧道工程施工安全技术规程》(TB10304-2009)有关规定。③施工用电设备数量在5台及以上,或用电设备容量在50kW及以上时,应编制施工用电施工组织设计,经技术负责人批准后实施。施工用电设备数量在5台以下,或用电设备容量在50kW以下时,应制定安全用电和电气防火措施。④施工现场应由专业技术人员建立用电安全技术挡案,定期对电力系统进行检查、量测。⑤施工电源及高低压配电装置应设专职人员负责运行与维护。⑥保护零线应由工作接地线、发电机中性点处、配电室、总配电箱、电源侧零线或总漏电保护器电源侧零线处引出,接地电阻值不应大于10Ω。⑦电气设备的金属外壳必须与保护零线连接。低压电器设备和器-6-材的绝缘电阻严禁小于0.5MΩ。⑧自备发电机组电源应与外电线路电源联锁,严禁并列运行供电。发电机组应设置短路保护和过载保护。⑨架空线路、电缆线路必须有短路保护和过载保护。⑩施工用电设施安装后,必须经过验收合格,方可投入使用。⑪电气设备或线路发生火警时,应首先切断电源,在未切断电源之前,严禁使身体接触导线或电气设备,严禁用水进行灭火。⑫发生人身触电时,应立即切断电源,方可对触电者做紧急救护。严禁在未切断电源之前与触电者直接接触。⑬电气装置遇跳闸时,应查明原因排除故障后,方可再行合闸,严禁强行合闸。⑭施工现场电动建筑机械或手持式电动工具的电源连接线,必须按其容量选用无接头的铜芯橡皮护套软电缆。其中绿黄双色线在任何情况下只可用作保护零线或重复接地线。⑮雷雨季节前,避雷装置应进行一次预防性试验,并应量测接地电阻。雷电后,应对阀型避雷器的瓷瓶、连接线和地线进行检查,确保完好无损。配电线路检查:①施工用电架空线路应符合下列规定:应采用绝缘导线。应设横担和绝缘子,并架设在电杆上。导线截面应满足计算负荷、线路末端电压偏移和机械强度要求。-7-②电杆埋设应牢固,回填土应夯实。③不得在外电架空线路正下方搭设作业棚、建造生活设施或堆放构件、材料及其他杂物等。④与外电架空线路的安全距离应符合下列规定:在架空线路一侧施工时,在建工程应与架空线路边缘之间保持安全操作距离,其值应符合表1的规定。表1在建工程外侧边缘与外电架空线路边线之间的安全距离外电线路电压等级(kV)<11~1035~11022330~500最小安全操作距离(m4.06.08.01015起重机的任何部位或被吊物边缘与10kV以下的架空线路边缘最小水平距离不得小于2.0m。施工现场的机动车道与外电架空线路交叉时,架空线路的最低点与路面的最小垂直距离应符合表2的规定。表2施工现场的机动车道与外电架空线路交叉时垂直距离外电线路电压等级(kV)<11~1035最小垂直距离(m)4.07.07.0⑤施工用电缆线路应符合下列规定:不应沿地面明设,当必需明设时应加设防护管。直接埋地敷设时应覆盖硬质保护层。穿越建筑物、铁路、道路等易受损伤的场所时,应加设防护管。⑥电缆架空敷设时,应沿墙或电杆做绝缘固定,最大弧垂处距地面不得小于2.0m。⑦施工现场低压供电线路的干线和分支线的终端,沿线每1km-8-处的保护零线以及配电室或总配电箱的保护零线应作重复接地。重复接地的接地电阻值不应大于10Ω。⑧电源导线严禁直接绑扎在金属架上。⑨在跨越铁路、公路、河流、电力线路的档距内,架空线不应有接头。配电室、配电箱及开关箱检查:①配电室应单独设立,并设有操作、维护通道,保持整洁、畅通,严禁堆放杂物。②配电柜应符合下列规定:两端应做接地(接零)。名称、用途、分路应做标记。严禁直接挂接临时用电设备。配电柜或线路维修时应挂停电标志牌。停、送电必须由专人负责,停止作业时应断电上锁。③总配电箱应靠近电源区域,分配电箱应设在用电设备相对集中的区域,与开关箱的距离严禁大于30m,开关箱应靠近用电设备,与用电设备水平距离不宜大于3m。④当动力配电与照明配电必需合置在同一箱内时,应分路设置。⑤配电箱、开关箱应采用厚度为1.2~2.0mm的铁板或阻燃绝缘材料制作,应能防雨、防尘。配电箱、开关箱应装设端正、牢固。⑥配电箱、开关箱应装设在干燥、通风、无外来物体撞击的场所,其周围应有足够2人同时工作的空间和通道。-9-⑦配电箱必须分设N线端子板和PE线端子板。总配电箱应设总隔离开关、分隔离开关、漏电保护器等电气设备。分配电箱应设总隔离开关、分隔离开关。开关箱应设隔离开关、漏电保护器,实行“一机一闸一漏一箱”制,严禁设置分路开关。⑧配电箱电力容量在15kW及以上的电源开关严禁采用瓷底胶木刀型开关。4.5kW及以上的电动机严禁用刀型开关直接启动。刀型开关应采用静触头接电源,动触头接载荷,严禁倒接线。⑨配电箱、开关箱应有名称、用途、分路标记,有锁,有防雨措施,严禁放置杂物,并由专人负责定期进行检查、维修。⑩对配电箱、开关箱进行维修、检查时,必须将其前一级电源断开,严禁带电作业。⑪每台用电设备必须设各自专用的开关箱,严禁用同一个开关箱直接控制两台及以上用电设备。⑫漏电保护器应符合现行国家标准《漏电电流动作保护器》(GB6829)的规定。照明检查:①施工现场的光照度应能满足相关作业的需要。②施工照明供电电压应符合下列规定:一般场所应为220V。行灯电压不得大于36V。高温、有导电粉尘、狭窄场所以及隧道作业地段,不得大于36V。潮湿和易触及照明线路场所,不得大于24V。-10-特别潮湿场所、导电良好的地面、锅炉或金属容器内,不得大于12V。③潮湿场所应选用密闭式或防水式照明器具;有爆炸和火灾危险的场所,按危险等级选用防爆型照明器具。④施工照明使用的220V碘钨灯应固定安装,其高度不得低于3m,距易燃物不得小于0.5m并不得直接照射易燃物,不得使用简易碘钨灯作为照明灯具。⑤夜间可能影响行人、车等安全通行的施工部位或设施、设备,必须设置警戒照明。隧道供电的检查:①隧道供电电压应符合下列要求:供电线路应采用380V/220三相五线制;照明电压:作业地段不得大于36V,成洞地段可采用220V;低压线路末端的电压降不得大于10%。②隧道内供电线路布置和安装应符合下列规定:成洞地段固定的电线路,应用绝缘良好的塑料绝缘导线架设;施工

1 / 17
下载文档,编辑使用

©2015-2020 m.777doc.com 三七文档.

备案号:鲁ICP备2024069028号-1 客服联系 QQ:2149211541

×
保存成功