人体静电消除器.

整理文档很辛苦,赏杯茶钱您下走!

免费阅读已结束,点击下载阅读编辑剩下 ...

阅读已结束,您可以下载文档离线阅读编辑

资源描述

《DQJ-5本安型人体静电消除器》技术资料大连东强防静电技术有限公司二00八年十一月目录一、概述···································································1二、人体静电·······························································21、人体静电带电方式·······················································22、人体静电参数···························································33、人体放电的危害和管理指标···············································34、典型气体引燃能量·······················································35、人体静电的标准规定·····················································4(1)GB12158-2006《防止静电事故通用导则》··································4(2)GB13348-92《液体石油产品静电安全规程》································5(3)SH3097-2000《石油化工静电接地设计规范》·····························5(4)静电安全指南(日本)1988··············································5(5)英国BS5958第2部分1991《防静电技术规范》·····················9(6)《大型浮顶储罐安全设计、施工、管理暂行规定》·····························10三、DQJ-5本安型人体静电消除器············································101、试验对比·······························································102、产品应用情况···························································143、产品规格与安装位置·····················································144产品设计依据··············································175人体静电消除器产品推荐建议··············································18四附件·································································191、DQJ-5-Ⅰ本安型人体静电消除器使用说明书·································202、DQJ-5-Ⅱ本安型人体静电消除器使用说明书·································223、DQJ-5-Ⅲ本安型人体静电消除器使用说明书·································241DQJ-5本安型人体静电消除器一、研发背景与必要性石油化工介质处理现场,多数处于可燃气暴露或存在气体泄露的高危场所,如装车、装船操作,油罐采样、测温、检尺操作,装置区采样操作,容器气体置换或吹扫清洗操作等等。在这些作业中,人体活动静电是现场作业不可避免的隐患源。二十世纪七、八十年代是石化企业人体静电事故的高峰期。如北京某炼厂1971年“5.3”航煤槽车采样爆炸,北方某加油站1976年3月、5月和1977年4月测温爆炸,上炼1981年“5.28”甲苯罐测温爆炸,抚油二厂1985“10.15”航煤罐采样爆炸等。这期间国外同类事故报道亦较多,如日本1961年4月二甲苯采样爆炸,1972年“1.8”苯罐采样爆炸,1976年1月苯罐采样爆炸等。针对人体静电事故频发现象,各国都制定或修改了原静电管理规定,并开发了导静电绳、防静电工作服等相应产品,与人体作业相关的静电事故明显减少。但最近一个时期国内类似事故又有所增加,如2000“12.12”、2002年“2.2”陕西永坪炼厂汽油罐采样着火事故,2002年“3.19”大连石化调和油罐闪爆事故,2004年9月泰州石化装置区采样着火事故,2005年春季济南某厂上罐采样着火事故等。这个现象在国外也有类似事故报道,如日本消防厅披露,在1982~1991年曾发生86例人体静电着火事故;美国石油设备协会(HPE)披露,1992~2005年曾发生162起汽车加油事故,其中85%的事故与人体静电或设备接地不良有关。中石化安监局2002年通过中石化安全工程研究院做了10个炼厂静电隐患调查,表1是上罐采样调研数据,这个统计从管理侧面上暴露了当前事故现象的背景:表1十个炼厂现场采样漏洞统计操作现象所占比例(%)上罐采样不穿防静电服40采样绳不合格40采样绳不做接地90提拉速度超标40采完样后不泄放静电就盖采样口10021、随着作业频率的增加,人们对以往事故教训和管理规定有些淡忘。如10个企业在现场作业演示中,采样绳不做接地的占90%,作业后没释放静电就盖采样口的占100%。2、市场防静电产品质量失控,企业也没有定检制度,现场管理有时失控。如大连石化“3.19”事故后,对刚买的89根20m长采样绳进行复查,合格率(R≤108Ω)仅16.6%,其中严重不合格的约有39%(见表2)。3、现有规范或规定有漏洞,且以限制操作为主,可操作性和可靠性较差。例如(GB/T4756-1998)手动采样要求作业后在采样口上风方向1m外摸一下金属物后再盖采样口盖,其漏洞有三:①按规定,采样口1.8m半径内均属防爆场所;②罐上所有金属物均涂复油漆,不能有效泄放人体静电;③当导静电绳失效或没有良好接地时,人体作业很容易积聚静电,作业中一旦触摸周围金属物,容易产生引燃性的火花放电。以上是目前事故增加的主要漏洞,在设备操作和管理上的其它漏洞有时也会恶化人体静电的危险。这些漏洞为:①没有穿戴合格的防静电鞋和服装;②提拉、投放速度过快;③现场没有导静电绳专用接地端子;④采样口附近没有允许泄放人体静电的专用接地器或消电器,等等。综上所述,石化企业的采样、测温、检尺作业和槽车灌装作业场所是人体静电放电几率最高的危险场所,单靠现场管理制度已不能有效限制人体静电引燃的危险性。因此,弥补上述漏洞而研发适合防爆场所使用的人体静电消除器,抑制当前事故趋势和改变人体静电的管理水平,是非常必要的。DQJ-5本安性人体静电消除器即是为适合上述要求而研发的,于2006年8月9日取得专利授权(ZL200520073235X)。二、人体静电简介1、人体静电带电方式表2采样绳电阻值测量数据阻值(Ω)数量(根)106~10715108~109391010~101118≥1012173(1)接触-分离或活动带电人体行走、投放采样绳、摩擦滤布、塑料桶倾倒粉体或石油产品、清釜作业等,人体会积聚静电。(2)感应带电粉体下料包装或传送塑料薄膜、橡胶带、无纺棉,以及汽车或容器未接地装卸介质等,附近人体会感应带电。(3)吸附或捕集带电,触摸带电介质带电在静电喷涂、蒸汽吹扫、水雾喷射、粉尘飞扬、喷溅加油等场所作业,人体会捕集荷电“微粒”带电;当人体接触传送带等荷电介质或未接地容器时,也会带电。2、人体静电典型参数(1)作业人体静电电压值人体行走静电电压:1~3kV;一般作业人体静电电压:2~5kV。(2)人体静电能量计算关于人体静电能量的计算,国外标准均按“导体”来定义。人体静电能量计算公式推荐:W=21CV2式中:C—人体电容,平均200PF(多数情况下100~400PF,少数可达1000PF)V—人体静电电压作业人体静电能量(2~5kV、200PF):0.4~2.5mJ。人体有电击感的临界电压:≥3kV,放电能量≥0.9mJ。3、人体放电的危害和管理指标人体放电形式主要为:(1)带电人体与接地体的放电,多数为火花放电。(2)带电介质与人体的放电,多数为刷形放电。(3)人体与人体之间的放电,多数为火花放电。44、典型气体引燃能量表3列出了几种典型气体的闪点和引燃能量。表3典型气体燃爆参数名称爆炸范围(V%)最小点火能(mJ)闪点(0C)汽油1.3~6.00.26-18~-24苯1.2~8.00.2-11丙烷2.1~9.50.25-104甲烷5.0~15.00.28-187乙烯3.0~340.096异丁烷1.8~8.50.52-81丁酮1.7~11.50.27-95、防止人体静电的相关规定(1)GB12158-2006《防止静电事故通用导则》6.5人体静电的防护措施6.5.1当气体爆炸危险场所的等级属0区和1区,且可燃物的最小点燃能量在0.25mJ以下时,工作人员穿防静电鞋、防静电服。当环境相对湿度保持在50%以上时,可穿棉工作服。6.5.2静电危险场所的工作人员,外露穿着物(包括鞋、衣物)应具防静电或导电功能,各部分穿着物应存在电气连续性,地面应配用导电地面。6.5.3禁止在静电危险场所穿脱衣物、帽子及类似物,并避免剧烈的身体运动。6.5.4在气体爆炸危险场所的等级属0区和1区工作时,应佩戴防静电手套。6.5.5防静电衣物所用材料的表面电阻率<5×1010Ω,防静电工作服技术要求见GB12014。56.5.6可以采用安全有效的局部静电防护措施(如腕带),以防止静电危害的发生。(2)GB13348-92《液体石油产品静电安全规程》4.7防止人体带电4.7.1当气体爆炸危险场所的等级属0区及1区时,作业人员应穿防静电工作服,防静电工作鞋、袜,且应配置导电地面(参见GB12014和GB4385)。4.7.2禁止在爆炸危险场所穿脱衣服、帽子或类似物。(3)SH3097-2000《石油化工静电接地设计规范》4.2储罐4.2.5为消除人体静电,在扶梯进口处,应设置接地金属棒,或在已接地的金属栏杆上留出一米长的裸露金属面。4.2.6与储罐管线相连接的法兰,如需防杂散电流和电化学腐蚀时,可选用电阻为104Ω~106Ω的绝缘法兰连接。4.4铁路栈台与罐车4.4.3在操作平台梯子入口处,应设置人体静电接地金属棒。每个鹤位平台处应设置接地端子,接地端子宜用接地线与接地干线直接相连。罐车及储罐用带有接地夹的软金属线与接地端子连接。4.5汽车站台与罐车4.5.2在操作平台梯子入口处或平台上,应设置人体静电接地棒。4.6码头4.6.4在船位陆上入口处,应设置消除人体静电的接地装置。(4)静电安全指南(日本)19884.3.2.1掌握人体的带电人体带电时,会成为气体蒸气和粉尘的引火源或者会有成为电击原因而发生火花放电的危险性。4.3.2.2泄漏电阻的管理指标人体泄漏电阻的管理指标如下:6(1)防止带电所需的泄漏电阻,一般来说为108Ω以下。但是在下列情况下,最好为107Ω以下。(a)氢、乙炔和二硫化碳等最小引燃能量为0.1mJ以下的气体蒸气有产生爆炸性混合气体的危险时。(b)因氧气泄漏和异常状态而产生氧气以及助燃性气体的氧浓度有增大的危险时。(c)组装、检查半导体元件时。(2)考虑到接触低压电线等而产生电击危险的情况,在满足上述(1)的同时。泄漏电阻最好在105Ω以上。4.3.2.3带电电位的管理指标人体的带电电位一般在100V以下。但若是在4.3.2.2(1)中(a)~(c)所示的数值时,带电电位最好在10V以下。第五章采用接地防止导体带电5.1接地的基本事项5.1.3接地的对象接地的对象,是指因产生静电和静电感应等而有带电的可能性,而其带电又是发生静电故障和灾害

1 / 27
下载文档,编辑使用

©2015-2020 m.777doc.com 三七文档.

备案号:鲁ICP备2024069028号-1 客服联系 QQ:2149211541

×
保存成功