合肥市工程建设技术标准DBHJ/T016-2015膨胀珍珠岩保温板建筑保温系统应用技术导则Technicalspecificationforapplicationofexpandedperliteinsulationboardthermalinsulationsystemonbuilding(审查稿)2015-0X-XX发布2015-0X-XX实施合肥市城乡建设委员会合肥市质量技术监督局DBHJ联合发布合肥市工程建设技术标准膨胀珍珠岩保温板建筑保温系统应用技术导则TechnicalspecificationforapplicationofexpandedperliteinsulationboardthermalinsulationsystemonbuildingDBHJ/T016-2015主编单位:合肥市建筑节能科技与勘察设计协会合肥市建筑质量安全监督站批准部门:合肥市城乡建设委员会施行日期:2015年XX月XX日2015.XX合肥前言为规范膨胀珍珠岩保温板建筑保温系统的设计、施工、监理和工程验收,确保工程质量和提高应用技术水平,导则编制组根据国家和地方现行相关技术规范、标准,积极借鉴、吸收兄弟省市同类标准的先进经验,结合合肥市地域、气候特点,以及膨胀珍珠岩保温板的性能及技术特征,经广泛调查和试验研究,认真总结工程实践经验,在专家论证并广泛征求意见的基础上,制定本导则。本导则共分7章和3个附录。主要内容包括:1总则、2术语、3基本规定、4性能指标、5设计、6施工、7质量验收、附录等。本导则由合肥市城乡建设委员会负责管理,合肥市建筑节能科技协会负责解释。请各有关单位在执行本标准过程中,注意收集资料,总结经验,并将需要修改、补充的意见和建议反馈给合肥市建筑节能科技协会(地址:合肥市庐阳区阜南路57号,邮编:230001,电话:0551-62655262,传真:0551-62638005),以供修编时参考。本导则主编单位:合肥市建筑节能科技与勘察设计协会合肥市建筑质量安全监督站安徽铭源新型建材科技有限公司本导则参编单位:安徽省建工集团有限公司安徽省施工图审查有限公司安徽省建筑科学研究设计院煤炭工业合肥设计研究院合肥华举建筑装饰工程有限公司合肥莱克利安保温科技有限公司信阳天意节能技术有限公司安徽省产品质量监督检验研究院安徽众锐质量检测有限公司本导则主要起草人员:甄茂盛陈刚鲁长权王俊贤章茂木于飞曹丽荣邵劲赵贵生孙魏郑鹏万普华杨国军王建春方明王东红朱平章琛肖方初曹必腾陈小金本导则主要审查人员:目次1总则···········································································································12术语···········································································································23基本规定···································································································64材料······································································································84.1一般规定···································································错误!未定义书签。4.2系统性能···························································································84.3系统组成材料·····················································································94.4材料进场检验···················································································175设计·········································································································205.1一般规定·························································································205.2构造设计·························································································205.3热工设计·························································································316施工·····································································································336.1一般规定·························································································336.2施工准备·························································································356.3施工工序·························································································366.4外墙外保温系统的施工与控制······························································446.5屋面和楼地面保温工程施工与控制························································506.6架空楼板保温工程施工与控制······························································516.7细部处理·························································································526.8安全文明施工和成品保护····································································547工程验收··································································································577.1一般规定·························································································577.2外墙外保温工程················································································617.3屋面保温工程···················································································657.4楼地面及架空楼板保温工程·································································67附录A···················································································错误!未定义书签。附录B膨胀珍珠岩保温板泛碱性能试验方法·····················································73附录C湿热强度损失率试验方法····································································75本导则用词说明····························································································78引用标准名录·······························································································79条文说明·····································································································8111总则1.0.1为贯彻建筑节能相关政策法规,规范膨胀珍珠岩保温板建筑保温系统的工程应用,保证工程质量,做到技术先进、质量可靠、安全适用、经济合理,制定本导则。1.0.2本导则适用于合肥市行政区域内抗震设防烈度为7度及以下的新建、改(扩)建民用建筑中采用膨胀珍珠岩保温板薄抹灰外墙外保温系统、膨胀珍珠岩保温板楼地面保温系统、膨胀珍珠岩保温板屋面的设计、施工及验收。既有建筑节能改造,工业建筑节能工程可参照执行。1.0.3膨胀珍珠岩保温板建筑保温系统的设计、施工、验收除应执行本导则外,尚应符合国家、行业和地方现行有关标准以及合肥市建筑节能的有关规定。22术语2.0.1膨胀珍珠岩保温板建筑保温系统expandedperliteinsulationboardofbuildingexternalthermalinsulationsystem用于建筑物外墙面、楼地面、屋面上,以膨胀珍珠岩保温板为保温层的建筑保温构造总称,包括膨胀珍珠岩保温板薄抹灰外墙保温系统、膨胀珍珠岩保温板楼地面保温和膨胀珍珠岩保温板屋面保温。2.0.2膨胀珍珠岩保温板expandedperliteinsulationboard以膨胀珍珠岩为主要材料,与非泡花碱类无机胶凝材料、外加剂等混合后,经模压成型、养护生产工艺制成的无机防火保温板材。2.0.3膨胀珍珠岩保温板外墙外保温系统expandedperliteinsulationboardexteriorinsulationsystem置于建筑物外墙外侧,由膨胀珍珠岩保温板、固定材料(胶粘剂、锚栓)、抹面层(抹面胶浆和耐碱玻纤网布)及饰面层等构成的外墙保温构造。2.0.4膨胀珍珠岩保温板楼地面保温系统expandedperliteinsulationboardinfloorinsulationsystem分为膨胀珍珠岩保温板楼地面保温系统和玻化微珠保温板底层地面保温系统,其中:膨胀珍珠岩保温板楼地面保温系统是置于建筑物地面结构层上,由粘结层、玻化微珠保温板保温层和保护层等构成的地面保温构造;膨胀珍珠岩保温板底层地面保温系统