1XXX工程反渗透装置(LXMRO-100)运行维护手册2目录1安全注意事项................................错误!未定义书签。1.1电气设备...................................错误!未定义书签。1.2机械设备...................................................51.2.1组件泄漏.................................................51.2.2离心泵...................................................51.2.3管线与阀门...............................................51.3停机.......................................................61.4通道.......................................................61.5安全防护设施...............................错误!未定义书签。1.6安全检查项目..............................错误!未定义书签。2概述........................................................82.1超滤膜过滤的简介..........................................82.2中空纤维滤膜和组件.........................................82.3V1072-35-PMC膜组件.......................................92.4V1072-35-PMC膜组件的操作条件.............................92.5V1072-35-PMC膜组件的特点...............................103超滤装置....................................错误!未定义书签。3.1装置基本使用条件..........................................113.2装置主要运行参数.........................................123.3装置反洗参数.............................................123.4V1072-35-PMC装置组成以及运行参数.......................134超滤装置的运行、反洗、快冲操作..............错误!未定义书签。4.1超滤装置概述..............................................144.1.1超滤系统的组成..........................................144.1.2超滤装置配套加药系统....................................144.1.3超滤单元主要设备及自动阀门编号.........................144.2启动前的检查内容..........................................1634.3超滤启动前的准备..........................................164.4超滤设备的运行操作说明....................................164.4.1超滤运行状态............................................164.4.2供水泵运行..............................................174.4.3反洗水泵运行............................................174.4.4超滤过滤状态...........................................174.4.5超滤反洗................................................174.4.6超滤快速冲洗............................................184.4.7超滤化学清洗............................................184.4.8超滤系统各设备和阀开关状态表...........................184.4.9反洗协调...............................................204.4.10超滤控制说明...........................................204.4.11超滤系统运行中的监督和调整.............................205运行装置的停机程序..........................................215.1手动操作模式下的停机......................................216运行监控内容...............................................226.2流量监控.................................................236.2.1产水流量................................................236.2.2浓水排放流量............................................246.2.3反洗流量...............................................246.2.4正洗流量...............................................246.3反洗间隔时间.............................................246.4操作压力..................................................246.4.1进出水压力差...........................................246.4.2进水压力...............................................256.4.3反洗水压力.............................................256.5进水水温..................................................256.6运行数据的记录............................................267超滤装置的过程控制........................................2747.1简介......................................................277.1.1手动控制模式...........................................277.1.2自动控制模式...........................................277.1.3装置关闭条件............................................287.2杀菌剂溶液注入装置........................................287.3装置内锁或者报警..........................................288系统的维护及故障分析.......................................308.1系统的日常维护...........................................308.2系统的故障分析............................................309超滤装置的清洗.............................................3351安全注意事项1.1电气设备1.按照规定检查各端子连接是否正确,是否牢固;2.在维修或更换故障电气单元时,必须把该部分从系统中断开。当有不同的电源接入同一控制柜,在打开控制柜之前,切断所有输入电源;3.检查所有接电装置的密闭性,确保不与外面的水接触;4、只有具备相应资质的电工才能进行事故的检修和电气系统维护。1.2机械设备1.2.1组件泄漏如果维护方法正确,且操作压力低于3.5bar的最大操作压力,V1072-35-PMC组件不会发生泄漏。一旦发生泄漏事故,必须立即关闭装置。关机后,检查漏水位置,并予以排除,尔后装置再次加压试水,如果继续泄漏,请立即与北京朗新明公司联系。1.2.2离心泵1.泵运转时,切勿对其进行维护等操作;2.要维护停运的泵,必须加以醒目标识;3.泵的维护结束后,把所有的防护件复原;4.确保泵的电机风扇的通风畅通;5.泵维护和维修结束后,应按新泵首次运行规定进行检查作业。1.2.3管线与阀门超滤装置的输水系统包括不同管径的管道以及连接件。1.确认所有管线的支撑、安装牢固;2.为避免系统承受过高的压力,在打开进水阀之前,须先打开出水阀。61.3停机为了确保操作人员或检修人员的安全,对所有设备的停机,都应遵循规定的停机程序。1.4通道在V1072-35-PMC设备周围应该有畅通的通道。地面应做防滑处理并且保持干燥、整洁。尽量不要在运行装置的附近存放设备、零件等。注意确保所有场地的照明,以方便操作和维护。1.5安全防护设施当使用化学药品进行清洗和进行带电作业时,务必穿带安全防护用品。如果不遵照下面的要求,将可能会导致无法挽回的人身伤害。当工作人员暴露在酸、碱、氧化剂环境下,必须穿戴橡胶手套、橡胶套服、头盔以及护目镜。当操作人员在带电作业时,应该戴绝缘手套、使用绝缘橡胶垫,必须有专人监护,以便必要时提供帮助和救护。安全淋浴装置必须保证处于良好工作状态。接触有害药品的人员必须全面了解药品各项性能,一旦发生危险时,应立即采取必要措施。发生溢出事故时,应按贵公司的安全操作规范进行处理。1.6安全检查项目在进行超滤装置操作之前,应检查是否落实了以下的安全措施:应检查项目用户1.在明显处张贴与处理紧急事故有关的单位、人员的联系电话[]2.所有设备的操作人员熟知现场安全防护措施[]3.熟知所有的泵和自动阀的关闭位置[]74.所有的泵/阀门、启动钮的标识清楚、正确[]5.确保设备周围通道畅通,光线充足[][]6.保持设备清洁和良好维护[][]7.保证设备必要的通风[][]8.不要超过超滤膜组件及管线的最大允许压力[][]82概述2.1超滤膜过滤的简介超滤膜过滤是一种膜分离技术,其膜为多孔性不对称结构,主要用于溶液中物质大分子级别的分离。超滤膜过滤过程是以膜两侧压差为驱动力,以机械筛分原理为基础的一种溶液分离过程;使用压力通常为0.1~0.6MPa,筛分孔径从0.05~0.1μm,截留分子量为5~100万道尔顿左右。其与所有常规过滤及微孔过滤的差别:分孔径小,几乎能截留溶液中所有的细菌、热源、病毒及胶体微粒、蛋白质、大分子有机物。是否有效分离除决定于膜孔径及溶质粒子的大小、形状及刚柔性外,还与溶液的化学性