OBO外部防雷技术

整理文档很辛苦,赏杯茶钱您下走!

免费阅读已结束,点击下载阅读编辑剩下 ...

阅读已结束,您可以下载文档离线阅读编辑

资源描述

12.02.20201CopyrightOBOBETTERMANN2010OBO外部防雷系统12.02.20202CopyrightOBOBETTERMANN2010引下线墙电气线路RL未设置足够的电气绝缘距离RL电气设备立式避雷针外部防雷中的电气绝缘距离12.02.20203CopyrightOBOBETTERMANN2010绝缘防雷IsolatedGFK-material12.02.20204CopyrightOBOBETTERMANN2010TheisolatedlightningprotectionsystemsmadeexternallightningprotectionconformtotheIEC62305possible.Thesecuritydistance“s”canbemanageduptoadistanceof750mm.Throughtheindividualpartsthesystemcouldbebuildupaccordingtodesire.isolatedlightningprotection12.02.20205CopyrightOBOBETTERMANN2010Type:1013-ES-16ItemNo.:5408976Iso-Combi-Setfor3-anglemountingL=750mmH=1500mmisolatedlightningprotection12.02.20206CopyrightOBOBETTERMANN2010Type:101VS-16ItemNo.:5408978Iso-Combi-SetforV-mountingL=750mmisolatedlightningprotection12.02.20207CopyrightOBOBETTERMANN2010Type:101FS-16ItemNo.:5408980Iso-Combi-Setforcrease-mountingL=750mmisolatedlightningprotection12.02.20208CopyrightOBOBETTERMANN2010Type:101VRS-16ItemNo.:5408982Iso-Combi-Setfortube-V-mountingL=750mmisolatedlightningprotection12.02.20209CopyrightOBOBETTERMANN2010平行布设的引线,保护屋面的电气线路Productrangeinsulatinglightningprotection-AdditionalwithØ=16mmGFK-rod-connector-andmounting-materialfor16mmGFK-rodsisolatedlightningprotection12.02.202010CopyrightOBOBETTERMANN2010OBOisCon®-SystemisolatedConductor12.02.202011CopyrightOBOBETTERMANN2010ConstructionofisCon-conductor弱导电性EVA,抗紫外线导电VPE绝缘VPE导电VPE35mm²铜芯VPE=交联聚乙烯EVA=乙烯—醋酸乙烯聚合物12.02.202012CopyrightOBOBETTERMANN2010PurposeoftheisolatedconductorOBOisCon®引下线用于外部防雷系统中,它能代替或减少IEC62305-3中所要求的电气绝缘距离.isCon®提供相当于0.75m空气或1.5m混凝土的电气绝缘距离.12.02.202013CopyrightOBOBETTERMANN2010LkkksmciIEC62305中电气绝缘距离计算公式12.02.202014CopyrightOBOBETTERMANN2010公式中的参数说明protectionclasski(IEC-62305-3)I0,1II0,075IIIundIV0,05materialkmair1Concreate,stone0,5GFK-material(manufacturer)0,7isolatedlightningprotectionnumberofdownconductorkc1121…0,54andmore1…1/nki雷区kc引下线数量km物质Lkkksmci12.02.202015CopyrightOBOBETTERMANN2010PlanningandinstallationisCon引下线可使用的长度可根据DINEN62603确定:防雷保护区可使用isCon®引下线的最大长度I9,37mII12,5mIII+IV15.00ms=0,75mki=0,05(LPS=3)kc=1(1根引下线)km=1(空气)l=引下线的使用长度0.0515.012.02.202016CopyrightOBOBETTERMANN2010GB50057中对绝缘距离的要求条纹3.2.5条独立避雷针和架空避雷线(网)的支柱及其接地装置至被保护建筑物及与其有联系的管道、电缆等金属物之间的距离(图3.2.1),应符合下列表达式的要求,但不得小于3m:防雷装置至被保护物的距离1、地上部分:当hx5Ri时,Sa1≥0.4(Ri+0.1hx)当hx≥5Ri时,Sa1≥0.1(Ri+hx)式中Sa1—空气中距离(m);Se1—地中距离(m);Ri—独立避雷针或架空避雷线(网)支柱处接地装置的冲击接地电阻(Ω);Hx—被保护物或计算点的高度(m)。12.02.202017CopyrightOBOBETTERMANN2010对比使用OBOisCon引下线没有设置电气绝缘距离wall电气装置金属引下线传统方法设置电气绝缘距离(空气)wall金属引下线OBOisCon引下线walls电气装置电气装置12.02.202018CopyrightOBOBETTERMANN2010Purposeoftheisolatedconductor传统方法绝缘距离使用OBOisCon线实现绝缘距离s12.02.202019CopyrightOBOBETTERMANN2010应用例子:通信基站卫星天线太阳能电池Applications12.02.202020CopyrightOBOBETTERMANN2010在Darmstadt实验室中的测试12.02.202021CopyrightOBOBETTERMANN2010isCon引下线电气绝缘距离测试(空气)Marx-GeneratorExamineeCT*Cutoffsparkgap*泻放控制回路0,75m12.02.202022CopyrightOBOBETTERMANN2010isCon引下线电气绝缘距离测试(固体)Marx-Generator1,5mCutoffsparkgapExamineeCT**泻放控制回路12.02.202023CopyrightOBOBETTERMANN2010关于isCon引下线铜芯的形式几截面积的要求:关于铜芯的直径要求VDE0185-305-3(IEC62305-3)12.02.202024CopyrightOBOBETTERMANN2010FunctionofisCon-conductor1,5mLightningcurrentSeveralkA位移电流,afewmA12.02.202025CopyrightOBOBETTERMANN2010S1,5m1,5m12.02.20202512.02.202026CopyrightOBOBETTERMANN2010S1,5m12.02.20202612.02.202027CopyrightOBOBETTERMANN2010S1,5m0,6m1,6m12.02.202027min.6mm²Forpotentialcontrol12.02.202028CopyrightOBOBETTERMANN2010s12.02.202029CopyrightOBOBETTERMANN2010potentialconnection025507510012515001530456075cmcmxPA-clampdistance(x)Separationdistance(s)如果经计算后安全距离要求小于750mm,可减短PA连接件与外壳接地端子之间的距离.Ifthecalculatedseparationdistance(s)isbelowthan75cm,youcanreducethedistancebetweenPA-clampandconnectingelement(x).12.02.202030CopyrightOBOBETTERMANN2010传统绝缘做法使用isCon超绝缘引下线s新产品商业应用推介:isCon超绝缘引下线系统电气绝缘做法比较1.有效保护外部重要设备及人身安全!2.释放天面空间!3.专用切割工具,快速切割,全现场制作!4.多种的连接备件,安装无须焊接,适用危险场所安装!12.02.202031CopyrightOBOBETTERMANN20104.新产品商业应用推介:isCon超绝缘4.5站立模式——全模块化设计,快速安装配备专用切割钳商业应用推介:isCon超绝缘引下线系统12.02.202032CopyrightOBOBETTERMANN2010isCon重要商业价值---人身安全的保护isCon绝缘引下线普通金属引下线钢结构厂房尤其危险12.02.202033CopyrightOBOBETTERMANN2010isCon重要商业价值---人身安全的保护ProtectionmeasuresagainsttouchvoltagesaccordingtoVDE0185-305-3(IEC62305-3)在某一些情况下,即使建筑物的外部绝缘防雷设施已经按照规范实施,但在引下线的附近,也会出现的危险触电隐患.这些安全隐患可采取以下措施减少:a)人很少接近;或者人出现在引下线或者与引下线相关结构附近的时间非常短.b)在引下线周围3米内的土壤,其土壤电阻率不小于5000ΩM.12.02.202034CopyrightOBOBETTERMANN2010VDE0185-305-3(IEC62305-3)中防止因接触引下线而发生触电危险的措施如果这些条件都不满足,应采取以下保护措施,防止人身触电危险:•出露下导线绝缘材料需要能承受一个100千伏,1,2/50μs的冲击耐受电压,例如:至少3毫米交联聚乙烯;OBOisCon引下线符合这条规定.•采用网格接地终端装置实现等电位化;•设置栏杆或警告标志,将人接触到引下线的可能性减到最低.12.02.202035CopyrightOBOBETTERMANN2010isCon线制作步骤1.2.3.4.5.6.12.02.202036CopyrightOBOBETTERMANN2010isCon线接头制作7.8.9.10.11.12.12.02.202037CopyrightOBOBETTERMANN2010快速组合thread-edrodArt.:5408971(L=270mm)Art.:5408972(L=340mm)Art.:5408973(L=430mm)Fang-FixconcreteblocksArt.:5403227FangFixedgeprotectionArt.:540323512.02.202038CopyrightOBOBETTERMANN2010-站立式快速安装12.02.202039CopyrightOBOBETTERMANN2010整体解决方案ConnectionelementCablebracketsPotentialconnectionCablebracketVA/PARoofcableholderVA/PAInsulatedinterceptionrodE

1 / 41
下载文档,编辑使用

©2015-2020 m.777doc.com 三七文档.

备案号:鲁ICP备2024069028号-1 客服联系 QQ:2149211541

×
保存成功