1一、荷载计算(一)、楼面及屋面永久荷载标准值:1、预制板楼面:楼面面层0.65KN/m2预空板及灌缝1.99KN/m230厚板底抹灰17×0.03=0.51KN/m2∑G=3.15KN/m2(取3.20KN/m2)2、现浇板楼面:楼面面层0.65KN/m2120厚现浇板3.00KN/m220厚板底抹灰17×0.02=0.34KN/m2∑G=3.99KN/m2(取4.00KN/m2)3、卫生间:楼面面层0.65KN/m2240厚水泥炉渣垫层0.24×13=3.12KN/m220厚水泥沙浆保护层0.02×20=0.4KN/m21.5厚聚氨酯涂层防水层15厚水泥沙浆找平层0.015×20=0.3KN/m280厚现浇板25×0.08=2.00KN/m220厚板底抹灰17×0.02=0.34KN/m2∑G=6.81KN/m2(取7.00KN/m2)4、屋面:40mm厚C30细石砼防水层25×0.04=1.00KN/m23mm厚SBS防水层0.30KN/m220mm厚水泥砂浆找平层20×0.02=0.40KN/m2膨胀珍珠岩找坡层(最薄处50mm)10×0.10=1.00KN/m2120厚钢筋混凝土板25×0.12=3.00KN/m220mm厚板底抹灰17×0.02=0.34KN/m2∑G=6.0KN/m25、砖墙永久荷载标准值:双面粉刷240墙双面粉刷17×0.02×2=0.68KN/m2240mm厚烧结多孔砖墙19×0.24=4.56KN/m2∑G=5.24KN/m22(二)、屋面、楼面均布活荷载标准值(建筑结构荷载规范GB50009—2001)1、客厅2.00KN/m22、门面3.50KN/m23、餐厅2.00KN/m24、卧室2.00KN/m25、楼梯间3.50KN/m26、阳台2.50KN/m27、卫生间2.00KN/m28、厨房2.00KN/m29、上人屋面2.00KN/m210、不上人屋面0.70KN/m211、基本风压0.35KN/m212、基本雪压0.45KN/m2一.荷载汇集:〈恒荷载〉1(楼面荷载:(1)卧室、书房:2木地板0.2KN/M2木格栅0.2KN/M2水泥砂浆找平层30mm:0.03*20=0.6KN/M楼板自重:2板厚100mm0.10*25=2.5KN/M2板厚110mm0.11*25=2.75KN/M2板厚120mm0.12*25=3.0KN/M2板厚160mm0.16*25=4.0KN/M2板下抹灰20mm:0.02*20=0.4KN/M合计:22板厚100mm3.90KN/M取4.0KN/M22板厚110mm4.15KN/M取4.2KN/M22板厚120mm4.40KN/M取4.4KN/M22板厚160mm5.40KN/M取5.5KN/M(2)客厅、餐厅32大理石面层20mm0.02*28,0.56KN/M2水泥砂浆结合层20mm0.02*20,0.40KN/M2水泥砂浆找平层30mm:0.03*20=0.60KN/M楼板自重:2板厚100mm0.10*25=2.5KN/M2板厚110mm0.11*25=2.75KN/M2板厚120mm0.12*25=3.0KN/M2板厚130mm0.13*25=3.25KN/M2板下抹灰20mm:0.02*20=0.4KN/M合计:22板厚100mm4.46KN/M取4.5KN/M22板厚110mm4.71KN/M取4.8KN/M22板厚120mm4.96KN/M取5.0KN/M1--22板厚130mm5.21KN/M取5.3KN/M(3)卫生间、厨房、阳台:2面砖0.55KN/M2水泥砂浆找平层30mm:0.03*20=0.6KN/M楼板自重:2板厚90mm0.09*25=2.25KN/M2板厚100mm0.1*25=2.5KN/M2板厚120mm0.12*25=3.0KN/M2板下抹灰20mm:0.02*20=0.4KN/M合计:22板厚90mm3.8KN/M取3.9KN/M22板厚100mm4.05KN/M取4.1KN/M22板厚120mm4.55KN/M取4.6KN/M(4)电梯厅、入户花园、楼梯平台:42地面按铺20mm厚石材考虑:0.02*28=0.56KN/M2水泥砂浆找平层30mm:0.03*20=0.60KN/M楼板自重:2板厚100mm0.1*25=2.50KN/M2板厚110mm0.11*25=2.75KN/M2板厚120mm0.12*25=3.00KN/M2板下抹灰20mm:0.2*20=0.4KN/M合计:22板厚100mm4.06KN/M取4.1KN/M22板厚110mm4.31KN/M取4.4KN/M22板厚120mm4.56KN/M取4.6KN/M(5)地下室顶板(无覆土时):2地面按铺20mm厚石材考虑:0.02*28=0.56KN/M2水泥砂浆找平层30mm:0.03*20=0.60KN/M2楼板自重160mm:0.16*25=4.0KN/M2板下设备:1.0KN/M2吊棚或抹灰:0.02*20=0.40KN/M22合计:6.56KN/M取6.7KN/M2--(6)地下室顶板(人防):2地面按铺20mm厚石材考虑:0.02*28=0.56KN/M2水泥砂浆找平层30mm:0.03*20=0.60KN/M2楼板自重250mm:0.25*25=6.25KN/M2板下设备:1.0KN/M2吊棚或抹灰:0.02*20=0.40KN/M22合计:8.81KN/M取9.0KN/M2(屋面荷载:5(1)上人屋面:2面砖:0.55KN/M240mm细石砼:0.04*25=1.0KN/M2防水层:0.10KN/M2水泥砂浆找平层20mm:0.02*20=0.40KN/M2挤塑板30mm0.05KN/M2焦渣砼找坡层2%,最薄处30mm:(4.3*2%+0.03)*17=1.97KN/M2水泥砂浆找平层20mm:0.02*20=0.4KN/M2楼板120mm厚:0.12*25=3.0KN/M2板下抹灰20mm:0.02*20=0.4KN/M22合计:7.87KN/M取8.0KN/M(2)不上人屋面:2防水层和细砂保护层:0.30KN/M2水泥砂浆找平层20mm:0.02*20=0.40KN/M2焦渣砼找坡层2%,最薄处30mm:(6.0*2%+0.03)*17=2.55KN/M2水泥砂浆找平层20mm:0.02*20=0.4KN/M2楼板120mm厚:0.12*25=3.0KN/M2板下抹灰20mm:0.02*20=0.4KN/M22合计:7.05KN/M取7.2KN/M(3)露台:2面砖:0.55KN/M240mm细石砼:0.04*25=1.0KN/M2防水层:0.10KN/M2水泥砂浆找平层20mm:0.02*20=0.40KN/M3--2挤塑板30mm0.05KN/M62焦渣砼找坡层2%,最薄处30mm:(3.3*2%+0.03)*17=1.63KN/M2水泥砂浆找平层20mm:0.02*20=0.4KN/M2楼板120mm厚:0.12*25=3.0KN/M2板下抹灰20mm:0.02*20=0.4KN/M22合计:7.53KN/M取7.7KN/M〈活荷载〉2z阳台:2.5KN/M2其它房间:2.0KN/M2(梁上线荷载(内外墙均按砂加气容重考虑):2250墙:7.0*1.3*0.25+0.8=3.1KN/M,2200墙:7.0*1.3*0.2+0.8=2.62KN/M,2100墙:7.0*1.3*0.1+0.8=1.8KN/M,2120墙:7.0*1.3*0.12+0.8=1.9KN/M,(1)层高2.9m250普通墙:q=3.1*(3.0-0.4)=8.06KN/M,取8.1KN/M250卫生间墙(双面瓷砖):q=(3.1+1.0)*(3.0-0.4)=10.66KN/M,取10.7KN/M250卫生间墙(单面瓷砖):q=(3.1+0.5)*(3.0-0.4)=9.36KN/M,取9.4KN/M120普通墙:q=1.9*(3.0-0.3)=5.13KN/M,取5.2KN/M120卫生间墙(双面瓷砖):q=(1.9+1.0)*(3.0-0.3)=7.83KN/M,取7.9KN/M120卫生间墙(单面瓷砖):q=(1.9+0.5)*(3.0-0.3)=6.48KN/M,取6.5KN/M200普通墙墙:q=2.62*(3.0-0.4)=6.82KN/M,取6.9KN/M200卫生间墙(双面瓷砖):q=(2.62+1.0)*(3.0-0.4)=9.42KN/M,取9.5KN/M200卫生间墙(单面瓷砖):q=(2.62+0.5)*(3.0-0.4)=8.11KN/M,取8.2KN/M100普通墙墙:q=1.8*(3.0-0.3)=4.86KN/M,取4.9KN/M100卫生间墙(双面瓷砖):q=(1.8+1.0)*(3.0-0.3)=7.56KN/M,取7.6KN/M100卫生间墙(单面瓷砖):q=(1.8+0.5)*(3.0-0.3)=6.21KN/M,取6.3KN/M7250普通墙有窗:8.1*0.8=6.48KN/M,取7.0KN/M计算如计平面的架,剪力计计的计荷计及合力作用位置。框构计18房屋计高米~地计准计计计区~计向计计中箭计所示580.64KN/m2方向.8某建筑物顶层的一根梁,梁长A米,荷载水平投影面积为B平方米,梁标高C米。荷载有自重、屋面活荷载,风荷载,雪荷载、屋面积灰荷载等,求该梁承载力极限状态下的荷载设计值、正常使用极限状态下的荷载设计值。现按学号往下排。序号梁长(m)荷载水平投影面积标高(m)梁自重(kN/m)屋面活荷(kN/m2)所在地区风载体型系数所在车间1310m21060.5北京-0.5机械厂冲天炉序号梁长(m)荷载水平投影面积标高(m)梁自重(kN/m)屋面活荷(kN/m2)所在地区风载体型系数所在车间23.512m2116.50.5上海-0.8炼钢氧气转炉序号梁长(m)荷载水平投影面积标高(m)梁自重(kN/m)屋面活荷(kN/m2)所在地区风载体型系数所在车间3413m21270.5广州-0.5炼钢氧气转炉序号梁长(m)荷载水平投影面积标高(m)梁自重(kN/m)屋面活荷(kN/m2)所在地区风载体型系数所在车间44.515m21380.5海口-0.7水泥厂有灰间序号梁长(m)荷载水平投影面积标高(m)梁自重(kN/m)屋面活荷(kN/m2)所在地区风载体型系数所在车间95510m21490.5拉萨-0.8水泥厂无灰间序号梁长(m)荷载水平投影面积标高(m)梁自重(kN/m)屋面活荷(kN/m2)所在地区风载体型系数所在车间65.512m21562成都-0.5机械厂冲天炉序号梁长(m)荷载水平投影面积标高(m)梁自重(kN/m)屋面活荷(kN/m2)所在地区风载体型系数所在车间7613m2166.52大连-0.5炼钢氧气转炉序号梁长(m)荷载水平投影面积标高(m)梁自重(kN/m)屋面活荷(kN/m2)所在地区风载体型系数所在车间8315m21772沈阳-0.8炼钢氧气转炉序号梁长(m)荷载水平投影面积标高(m)梁自重(kN/m)屋面活荷(kN/m2)所在地区风载体型系数所在车间93.510m21880.5长春-0.5水泥厂有灰间序号梁长(m)荷载水平投影面积标高(m)梁自重(kN/m)屋面活荷(kN/m2)所在地区风载体型系数所在车间10412m21990.5北京-0.7水泥厂无灰间序号梁长(m)荷载水平投影面积标高(m)梁自重(kN/m)屋面活荷(kN/m2)所在地区风载体型系数所在车间114.513m22060.5上海-0.9机械厂冲天炉序号梁长(m)荷载水平投影面积标高(m)梁自重(kN/m)屋面活荷(kN/m2)所在地区风载体型系数所在车间12515m2216.50.5广州-0.5炼钢氧气转炉序号梁长(m)荷载水平投影面积标高(m)梁自重(kN/m)屋面活荷(kN/m2)所在地区风载体型系数所在车间135.510m22270.5海口-0.5炼钢氧气转炉序号梁长(m)荷载水平