第1页共41页火灾自动报警系统竣工资料施工安装质量记录北京安迪盛安全系统自动化有限公司江苏分公司2015年月日第1页共41页目录火灾自动报警系统质量保证资料核查表(编号:A-1).....................................................................................6图纸会审记录(编号:1).....................................................................................................................................7设计变更明细表(编号:2).................................................................................................................................8技术交底记录(编号:3).....................................................................................................................................9施工技术核定单(编号:4)...............................................................................................................................10施工组织设计(方案)(编号:5).....................................................................................................................11开工报告(编号:6)...........................................................................................................................................12设备、材料相关证件汇总表(编号:7)...........................................................................................................15设备开箱检查记录(编号:8)...........................................................................................................................16材料检查记录(编号:9)...................................................................................................................................17火灾自动报警系统配管/配线安装检查记录(编号:A-2).............................................................................18火灾自动报警系统电缆敷设检查记录(编号:A-3).......................................................................................20消防配电线路敷设检查记录(编号:10).........................................................................................................21火灾自动报警系统接地电阻测试记录(编号:A-4).......................................................................................22火灾自动报警系统绝缘电阻测试记录(编号:A-5).......................................................................................23火灾自动报警系统配管配线隐蔽验收记录(编号:A-6)...............................................................................24火灾自动报警系统电缆敷设隐蔽验收记录(编号:A-7)...............................................................................25消防配电线路隐蔽验收记录(编号:11).........................................................................................................26火灾自动报警系统报警控制器安装检查记录(编号:A-8)...........................................................................27火灾自动报警系统联动控制器安装检查记录(编号:A-9)...........................................................................28火灾自动报警系统探测器安装检查记录(编号:A-10).................................................................................29火灾自动报警系统手动报警按钮安装检查记录(编号:A-11).....................................................................32火灾自动报警系统手动报警按钮安装检查记录(编号:A-11).....................................................................33火灾自动报警系统警报装置安装检查记录(编号:A-12).............................................................................34火灾自动报警系统探测、报警点全点试验记录(编号:A-13).....................................................................35火灾自动报警系统联动控制点全点试验记录(编号:A-14).........................................................................37火灾自动报警系统调试报告(编号:A-15).....................................................................................................39火灾自动报警系统系统自检报告(编号:A-16).............................................................................................41火灾自动报警系统试运行记录(编号:A-17).................................................................................................44竣工报告(编号:12).........................................................................................................................................45设备移交清单(编号:13).................................................................................................................................46第1页共41页火灾自动报警系统质量保证资料核查表(编号:A-1)工程名称王府国际花园消防改造工程建设单位王府国际花园施工单位北京安迪盛安全系统自动化有限公司江苏分公司核查日期2015年月日类别项目份数核查情况前期图纸会审、技术交底记录设计变更、技术核定单施工组织设计(方案)开工报告出厂检验设备(材料)相关证件汇总表设备(材料)检查记录隐蔽验收记录配管配线隐蔽验收记录电缆敷设隐蔽验收记录消防配电线路隐蔽验收记录安装检查试验记录各类安装检查记录各类测试、试验记录调试报告自检报告运行记录竣工报告设备移交清单其他核查意见:技术负责人质检员第册第页第1页共41页图纸会审记录(编号:1)工程名称王府国际花园消防改造工程建设单位王府国际花园设计单位施工单位北京安迪盛安全系统自动化有限公司江苏分公司会审地点会审日期年月日会审主题图纸会审内容议定事项设计单位代表建设(监理)单位代表施工单位代表注:设计修改应由设计单位另发变更通知单。表内不够填写时,可附后。第册第页第1页共41页设计变更明细表(编号:2)序号设计变更通知单号页数变更内容(简述)审批情况技术负责人质检员填报日期年月日注:后附设计变更通知单份第册第页第1页共41页技术交底记录(编号:3)工程名称王府国际花园消防改造工程建设单位王府国际花园分项工程名称消防报警、联动施工单位北京安迪盛安全系统自动化有限公司江苏分公司技术交底内容消防电气配管、线路采用暗敷时,且保护层厚度不应小于30mm,参加人员技术负责人交底人记录人交底日期年月日第册第页第1页共41页施工技术核定单(编号:4)工程名称王府国际花园消防改造工程建设单位王府国际花园设计单位施工单位北京安迪盛安全系统自动化有限公司江苏分公司需核定的技术问题内容说明项目经理技术负责人施工员填报日期年月日反馈意见设计单位建设(监理)单位技术负责人核定日期:年月日第册第页第1页共41页施工组织设计(方案)(编号:5)工程名称王府国际花园消防改造工程建设单位王府国际花园设计单位施工单位北京安迪盛安全系统自动化有限公司江苏分公司施工组织设计(方案):附后批准人审核人编制人编制日期年月日注:如本页不够填写,可附后。第1页共41页第册第页开工报告(编号:6)工程名称王府国际花园消防改造工程合同编号建设单位王府国际花园工程造价设计单位计划工期施工单位北京安迪盛安全系统自动化有限公司江苏分公司开工日期年月日工程内容本工程内容室内报警联动。序号工程开工条件实际情况1施工图会审、技术交底情况已交底2施工组织设计(方案)批准交底情况已批准3施工图预算编制情况已编制4物资供应、设备材料落实情况已落实5三通一平、土建条件情况已满足6施工机械设备落实情况已落实7劳动力落实情况已落实8安全技术措施落实情况已落实910备注