第1页(项目名称)10kV高压电容器柜技术规格书供审查版本日期版本说明编制审核审定日期签字技术规格书总页数:第2页目录1概述···················································································32术语定义···········································································33招标内容和技术要求····························································34遵循的标准及规范·······························································95投标中技术文件的最低要求·················································116检验与验收······································································127购方提供的文件································································138卖方需提供的技术文件·······················································139卖方提供技术文件要求·······················································1510备品备件和专用工具························································1711技术服务········································································17附录1:卖方文件资料要求列表················································18附录2:10KV干式电容器柜数据表···········································19第3页1概述本技术规格书为10kV高压电容器组专用技术规格书,作为招(投)标技术文件。本技术规格书提出了对变电所中10kV高压电容器组的设计、制造、配套、文件、服务和验收等方面的最低要求。对技术规格书中未提及的但又是必须的技术要求,卖方有责任提出建议,提供完善的性能。2术语定义用户:购方:卖方:3招标内容和技术要求3.1卖方资格3.1.1卖方应提供成熟技术和产品,并需有相关业绩和实际应用证明。3.1.2所有主要设备的卖方的工厂均需获得ISO9000认证。3.1.3卖方需递交简介,内容包括为本项目设计、制造、供货、提供售后服务和技术支持的卖方、主要零部件分包商、部门、工厂。3.2总体要求3.2.1卖方必须根据所提供的技术要求和资料给出尽可能详细的设备配套方案(包括必要的图纸),技术文件至少应包括:(1)选型样本;(2)安装使用说明书;(3)所遵循的出厂检验标准;(4)投标中应标的有关条款解释;(5)卖方必须根据所提供的技术要求和资料给出尽可能详细的设备配套方案第4页(包括必要的图纸),说明设备的结构组成、工作参数、设备参数、设备安全措施及备品备件清单等。(6)技术规格书要求的其它内容3.2.2所有投标技术文件、合同技术文件、设计技术文件和图纸等均使用SI单位制。3.2.3卖方对技术规格书和数据表中遗编或认为存在不妥的地方可提出,双方讨论确定。招标技术附件,需经用户和设计方确认后生效。3.3设计基础数据3.3.1使用环境条件㈠环境条件1、气温室内最高气温40℃室内最低气温-10℃2、海拔高度:≤1000m;3、湿度及污秽:日平均相对湿度:不大于95%月平均相对湿度:不大于90%。污秽等级:Ⅱ级4、地震烈度Ⅶ度;5、周围空气应不受腐蚀性气体、水蒸汽明显污染。6、无经常性剧烈振动.㈡系统条件1、额定电压10kV2、最高工作电压12kV3、额定频率50HZ4、中性点连接不接地系统(10)地震地震VII裂度区,属地震多发区(动峰值加速度0.185g)(11)安装地点10kV电容器室内第5页(12)爬电比距:不小于31mm/kV3.3.2技术参数和要求(1)技术要求无功自动补偿成套装置的额定电压为12kV,考虑6%的电抗,故总装机容量为2193kvar/段(额定输出容量为1600kvar/段,共2段),为满足不同负荷需求,每段电容器进行分组投切,分组容量分别为1000/组,300/组*2。用来提高工频电力系统的功率因数,改善和提高电压质量,降低设备及线路损耗。无功自动补偿成套装置必须配有高压型无功补偿控制器(不得采用低压型),能够根据电网负荷状况适当的投切电力电容器组,以满足负荷变动所引起的无功变化,从而提高系统功率因数,改善电压质量。装置主要由真空接触器、隔离开关、电容器、放电线圈、电抗器、氧化锌避雷器、柜壳等部分组成。1)电容器采用督凯提电容器型号:6950D457*6/6950D137*12芯子最热点温度要求:≤+75℃耐受爆破能量:12kW·s外绝缘泄露比距:3.1cm/kV国际知名品牌,原装进口元件;具备ISO9001同品牌认证,认证同产品名称;电容器交货后提供原厂试验报告;采用无毒、可生物降解的有机油填充,具备稳定的电气性能;绝缘瓷套管与金属外壳采用金属涂敷(焊接方式),具有完美的密封性,不漏油;外观无缝连接;金属外壳为柔性钢壳,可以补偿内部绝缘油体积的变化,并防止辐射和磁涡流;单只电容器偏差:-5%∽+10%;电容器平均损耗0.01%(0.1w/kvar);内置放电电阻,断电后5分钟内将残余电压降至50V以下;最大峰值暂态电流:100In,最大允许过电流Imax≤1.3In;可选择的电容器元件的保护方式:外附熔丝,避免内附熔丝导致的由于容量变化而使谐振点偏移;第6页低温局放:在温度范围下限值时的局部放电熄灭电压不低于1.15Un;电容器引出端子的套管能承受≥980N的水平拉力;运行电压10kv以上的,采用最高系统电压24kV绝缘等级电容器,耐冲击测试电压为50/150kV;单台电容偏差:最高值:+10%;最低值:-5%总电容量与实测之差不超过+10%、0%;端子与外壳绝缘水平:1min工频耐压(有效值):50kV雷电冲击耐压(峰值):150kV局放熄灭电压:常温下加压至局部放电起始后历时1s。降压至1.35Un保持10min,然后将电压升到1.6Un保持10min,此时应无明显局部放电,电容器在此温度下局放熄灭电压应不低于1.15倍额定电压。电起强度:电容器间介质应承受下列两种试验电压之一,历时10s:工频交流电压Ut=2.15Un,直流电压Ut=4.3Un。稳态过电流:在不超过1.3In的稳态过电流下连续运行。耐受涌流:能承受每年1000次100倍电容器额定电流的涌流冲击。稳态过电压工频过电压1.101.151.201.30持续时间12h/天每24h中30min5min1min过渡过电压电容器能承受第一个峰值不超过22Un持续1/2周期的过渡电压。电容器套管应能承受500N水平拉力。设备密闭性能应能以保证在各个部分均达到电气介质允许的最高运行温度时不出现渗漏。2)放电线圈额定一次电压:11/3第7页额定二次电压:100V相数:单相额定频率:50Hz电压变比允差:±1%绝缘水平1分钟工频耐压(有效值):42kV(干);35kV(湿)雷电冲击耐压(全波1.2/50uS峰值):75kV3)干式铁芯串联电抗器相数:三相系统额定电压:12kV频率:50Hz额定电抗率:6%外绝缘泄露比距:3.1cm/kV(相对于12kV)额定容量:额定端电压:381V额定电流:40A长时间过流:1.43In要求电抗器在通过>25Ie时,其电抗>1%电抗器2s热稳定电流:>10kA-3s电抗器动稳定电流:25kA4)熔断器(以下型号为参考用标准型号)BRW-5)隔离接地开关数量:额定电流:630A系统额定电压:12kV4s热稳定电流(有效值):20kA动稳定电流峰值:50kA6)氧化锌避雷器系统标称电压:10kV避雷器持续运行电压:15kV避雷器额定电压:18.8kV数量:1/…μs冲击电流1kA5kA10kAUP(kV)UP(kV)UP(kV)39.348.254.3第8页8/20…μs冲击电流1kA5kA10kA20kAUP(kV)UP(kV)UP(kV)UP(kV)9.043.546.051.030/60μs冲击电流100A250A500A1000AUP(kV)UP(kV)UP(kV)UP(kV)33.935.736.938.47)真空接触器数量:额定电压:12kV单路额定电流:400A额定雷电冲击耐受电压:75kV1min工频耐受电压:42kV机械寿命:300000次(2)主要技术参数装置额定电压:11kV(±10%),3相。额定频率:50Hz稳态过电流能力:≤1.3In稳态过电压能力:≤1.1Un一次接线方式:单星形接法电抗器电抗率:6%柜体结柜:电容器柜面采用冷轧钢板(设有观察窗)表面喷塑。温升要求:各元件温升均满足IEC及GB最新版的要求及高压电器长期工作发热的规定。冷却方式:自然风冷安装位置:户内防护等级:IP41机械强度:起吊、运输、安装等过程中结构的牢固及元件的可第9页靠连接。(3)电容器保护电容器保护采用开口三角保护。电容器需装设外熔丝。其余电容器保护由10kV电容器柜综合保护装置实现,具体要求参见微机综合自动化系统技术规格书。(4)满足凝露试验要求,同时还应满足湿热带三防(防湿热、防盐雾、防霉菌)要求。(5)柜体颜色4遵循的标准及规范合同中所有设备、备品备件,除本技术规格书中规定的技术参数和要求及所列标准外,其余均应遵照最新版本的中华人民共和国国家标准、国际电工委员会(IEC)标准及国际单位制(SI)。当上述标准之间的规定有差异时,以最严格的标准为准。如果卖方采用自己的标准或规范,应符合或不低于中华人民共和国国家、行业相关法规、规范的要求。卖方必须使其设计、制造、检验和试验等符合指定的标准、规范。当卖方不能接受本技术规格书中的某些条款时,应将偏离内容和修正意见及时通知买方。4.1国家标准法律、法规及规程规范《3~35kV交流金属封闭式开关设备》GB3906-1991《高压开关设备和控制设备标准的共用技术要求》GB/T11022-1999《户内交流高压电容器柜订货技术条件》DL/T404-97《交流高压断路器订货技术条件》DL/T402-1999《电力用电压互感器订货技术条件》DL/T726-2000《电力用电流互感器订货技术条件》DL/T725-2000《局部放电测量》GB/T7354-1987《外壳防护等级》GB4208-93《高压电力设备外绝缘污秽等级》GB6582/T-93第10页《高电压试验技术第1部分:一般试验要求》GB/Tl6927.1-1997《高电压试验技术第2部分:测量系统》GB/Tl6927.2-1997《交流无间隙金属氧化物避雷器》GB11032-2000《高压开关设备常温下的机械试验》GB/T3309-1989《电工电子产品基本环境试验规程》试验Ka:盐雾试验方法GB/T2423.17-1993《电工电子产品环境试验》第二部分试验方法试验J和GB/T2423.16-1999《电工电子产品基本环境试验规程》试验Db:交变湿热试验方法GB/T2423.4-1993《外壳防护等级》GB4208-1993《机电产品包装通用技术条件》GB/T13384-1992《高压开关设备抗地震性能试验》GB/T13540《包装储运图示标记》GB191-2000《高压输变电设备的绝缘配合》GB/T311.1-1997《电工成套装置中的指示灯和按钮的颜色