Huitex72117~10Tel:+886-6-570-2181Fax:+886-6-570-0065WebSite:@huitex.com20028Huitex®Geomembrane……………………………………………..……………....……………………………………………..…...…….…………………………………………………..…...…….…………………………………………………………………..…………………………………………………..….………………………………………………………………………………..….…(ASTM)….(CNS)…………..……………………..…………(ASTM)……………………………………………………(CNS)……………………………………………...………ASTMCNSGRI..…………………………………………..(2002.08,Huitex®Geomembrane1Huitex®Geomembrane2Huitex®Geomembrane1.NaturalResinHDPELLDPEVFPE2.COA3.3.1g/mlASTMD1505/D792g/10minuteASTMD1238(1902.16kg)500003.2HDPELLDPEg/mlASTMD1505/D7920.9320.915g/10minuteASTMD1238(1902.16kg)≤1.0≤1.03Huitex®Geomembrane4.4.1g/mlASTMD1505/D792ASTMD160350004.2g/mlASTMD1505/D7921.0%ASTMD1603≥334Huitex®GeomembraneASTMD5199ASTMD5994GRIGM12ASTMD1505/D792ASTMD63850mm/ASTMD1004ASTMD48335Huitex®GeomembraneASTMD5397(Appendix)2%VFPEASTMD5323VFPEASTMD5617ASTMD1603ASTMD3015(OIT)ASTMD389585OITASTMD5721ASTMD3895OITGRIGM11ASTMD5885((ASTM)(CNS)6Huitex®Geomembrane7Huitex®GeomembraneASTMHD050HD075HD100HD150HD200HD250HD300,mmASTMD51990.500.450.750.671.000.901.501.352.001.802.502.253.002.70,g/ml()ASTMD1505/D7920.940.940.940.940.940.940.94(1):()1.,KN/m2.,KN/m3.,4.,ASTMD638450mm/min91413700112113700162813700254313700345713700407113700448013700,N()ASTMD100473100138210275330374,N()ASTMD4833159238316475636793960,ASTMD16931500150015001500150015001500,()ASTMD16032-32-32-32-32-32-32-3ASTMD5596(2)(2)(2)(2)(2)(2)(2),()ASTMD389510010010010010010010085()90,ASTMD5721ASTMD389555555555555555(4)()1600,GM11ASTMD588550505050505050(1).533mm.50mm(2).1012(3).7520UV6042002.08,8Huitex®Geomembrane()(CNS)HD050HD075HD100HD150HD200HD250,mmCNS41740.500.450.750.711.000.901.501.432.001.902.502.38()CNS29400.940.940.940.940.940.94()1.,kgf/cm22.,kgf/cm23.,4.,CNS4396250mm/min300300700700300300700700300300700700300300700700300300700700300300700700,kgf/cm()CNS3559B50mm/min1301301301301301301.,2.,3.,4.,CNS12494CNS4396±5±5±5±5±5±5±5±5±5±5±5±5±5±5±5±5±5±5±5±5±5±5±5±5,()CNS3276111111,kgf/cm2()CNS12494CNS4396150150150150150150,1.,2.,CNS3143100,15±3±3±3±3±3±3±3±3±3±3±3±3,()CNS124945005005005005005009Huitex®Geomembrane()(ASTM)VF050VF075VF100VF150VF200VF250,mmASTMD51990.500.450.750.671.000.901.501.352.001.802.502.30,g/ml()ASTMD1505/D7920.9390.9390.9390.9390.9390.939(1):()1.,kN/m2.,ASTMD638450mm/min1380020850278504085055850668502%,kN/m(.)ASTMD53232103704206308401050,%(.)ASTMD5617303030303030,N()ASTMD10045071100150200250,N()ASTMD4833120190260380520620,()ASTMD16032-32-32-32-32-32-3ASTMD5596(2)(2)(2)(2)(2)(2),()ASTMD389510010010010010010085()90,ASTMD5721ASTMD3895353535353535(3)()1600,GM11ASTMD5885353535353535(1).550mm(2).1012(3).7520UV6042002.08,10Huitex®Geomembrane()(ASTM)HX100HX150HX200HX250,mmASTMD59941.000.901.501.402.001.802.502.30(mm)(1)GRIGM120.250.250.250.25,g/cm3()ASTMD1505/D7920.940.940.940.94(2):()1.,KN/m2.,KN/m3.,4.,ASTMD638450mm/min151313150231613150302113150382613150,N()ASTMD1004125187250312,N()ASTMD4833267401534668,ASTMD16931500150015001500,()ASTMD16032-32-32-32-3ASTMD5596(3)(3)(3)(3),()ASTMD389510010010010085()90,ASTMD5721ASTMD389555555555(4)()1600,GM11ASTMD588550505050(2).(3).533mm.50mm.(4).101,2(5).7520UV6042002.08,11Huitex®Geomembrane(ASTM)HD050HD075HD100HD150HD200HD250,mmASTMD51990.500.450.750.711.000.951.501.42.001.852.502.30,g/ml()ASTMD1505/D7920.940.940.940.940.940.94(1):()1.,KN/m2.,KN/m3.,4.,ASTMD638450mm/min8.51413700112113700162813700254313700345713700407013700,N()ASTMD100473100138210275330,N()ASTMD4833159240320480640800,ASTMD5397Appendix200200200200200200,()ASTMD16032-32-32-32-32-32-3ASTMD3015ASTMD5596(2)(3)(2)(3)(2)(3)(2)(3)(2)(3)(2)(3),(4)()ASTMD389510010010010010010085()90,ASTMD5721ASTMD3895555555555555(5)()1600,GM11ASTMD5885(6)50(6)50(6)50(6)50(6)50(6)50(1).533mm.50mm(2).A1A2B1(3).1012(4).(5).(6).12002002.08,12Huitex®Geomembrane(CNS)HD050HD075HD100HD150HD200HD250,mmCNS41740.500.450.750.711.000.901.501.432.001.902.502.38()CNS29400.940.940.940.940.940.94()1.,kgf/cm22.,kgf/cm23.,4.,CNS4396250mm/min300300700700300300700700300300700700300300700700300300700700300300700700,kgf/cm()CNS3559B50mm/min1301301301301301301.,2.,3.,4.,CNS12494CNS4396±5±5±5±5±5±5±5±5±5±5±5±5±5±5±5±5±5±5±5±5±5±5±5±5,()CNS3276111111,kgf/cm2()CNS12494CNS4396150150150150150150,1.,2.,CNS3143100,15±3±3±3±3±3±3±3±3±3±3±3±3,()CNS124945005005005005005002002.08,13Huitex®GeomembraneASTMCNSGRIASTM1.D638TestMethodforTensilePropertiesofPlastics2.D792SpecificGravity(RelativeDensity)andDensityofPlasticbyDisplacement3.D1004TestMethodforInitialTearResistanceofPlasticsFilmandSheeting4.D1238TestMethodforFlowRatesofThermoplasticsbyExtrusionPlastometer5.D1505TestMethodforDensityofPlasticsbyDensity-GradientTechnique6.D1603TestMethodforCarbonBlackinOlefinPlastics7.D3015PracticeforMicroscopicalExaminationofPigmentDispersioninPlasticCompounds8.D3895TestMethodforOxidativeInductionTimeofPolyolefinsbyDifferentialScanningCalorimetry9.D4833TestMethodforIndexPunctureResistanceofGeotextiles,GeomembraneandRelatedProducts10.D5199TestMethodforMeasuringNominalThicknessofGeotextiles