SB-2805SAeries豪威系列磁盘陈列使用手册SB-2805SAeries系统说明硬盘灯指示硬盘动作指示灯绿灯表示:硬盘已通电红灯表示:未安装硬盘橙灯表示:硬盘坏了蓝灯表示:硬盘正在进行动作硬盘指示灯1前板说明1.1硬盘灯指示SB-2805SAeries3.菜单Menu下面将列出SB-2805SA的设定菜单menu及选择项目QuickVolume/RaidSetupRaidSetFunctionVolumeSetFunctionPhysicalDrivesMainMenuRaidSystemFunctionEthernetConfigurationViewSystemEventsClearEventBufferHardwareMonitorSystemInformationRaid0SelectedCapacitySelectStripeSize4K,8K,16K,32K,64K,128KCreateVol/RaidSetYes,NoRaid1or0+1SelectedCapacitySelectStripeSize4K,8K,16K,32K,64K,128KCreateVol/RaidSetYes,NoRaid0+1+SpareSelectedCapacitySelectStripeSize4K,8K,16K,32K,64K,128KCreateVol/RaidSetYes,NoQuickVolume/RaidSetupRaid3Raid5SelectedCapacityCreateVol/RaidSetYes,NoSelectedCapacitySelectStripeSize4K,8K,16K,32K,64K,128KCreateVol/RaidSetYes,NoRaid3+SpareSelectedCapacityCreateVol/RaidSetYes,NoRaid5+SpareSelectedCapacitySelectStripeSize4K,8K,16K,32K,64K,128KCreateVol/RaidSetYes,NoRaid6SelectedCapacitySelectStripeSize4K,8K,16K,32K,64K,128KCreateVol/RaidSetYes,NoRaid6+SpareSelectedCapacitySelectStripeSize4K,8K,16K,32K,64K,128KCreateVol/RaidSetYes,NoSB-2805SAeriesCreateRaidSetSelectIDEDrivesforRaidSetCh01~Ch16CreateRaidSetYes,NoDeleteRaidSetEditTheRaidSetNameSelectRaidSetToDeleteDeleteRaidSetYes,NoAreyousure?Yes,NoExpandRaidSetSelectIDEDrivesforRaidSetExpansionSelectDrivesIDEChannelChxx~Ch16ExpandRaidSetYes,NoAreyousure?Yes,NoRaidSetFunctionActivateRaidSetSelectRaidSetToActiveActivateRaidSetYes,NoAreYouSure?Yes,NoCreateHotSpareDiskSelectDrivesforHotspare,Max3HotsparesupportedChxx~Ch16CreateHotSpareYes,NoDeleteHotSpareDiskSelectTheHotSpareDeviceToBeDeletedDeleteHotSpareYes,NoRaidSetInformationSelectRaidSetToDisplayCreateVolumeSetCreateVolumeFromRaidSetVolumeCreationCreateVolumeVolumeName,RaidLevel,Capacity,StripeSize,SCSIChannel,SCSIID,SCSILUN,CacheMode,TagQueuing,MaxSyncRateYes,NoInitializationModeForeground,BackgroundDeleteVolumeSetDeleteVolumeFromRaidSetSelectVolumeToDeleteDeleteVolumeSetYes,NoAreyousure?Yes,NoVolumeSetFunctionModifyVolumeSetModifyVolumeFromRaidSetSelectVolumeToModifyVolumeModificationVolumeName,RaidLevel,Capacity,StripeSize,SCSIChannel,SCSIID,SCSILUN,CacheMode,TagQueuing,MaxSyncRateCheckVolumeSetModifyVolumeYes,NoAreyousure?Yes,NoCheckVolumeFromRaidSetSelectVolumeToCheckCheckTheVolumeYes,NoStopVolumeCheckStopAllVolumeCheckYes,NoAreyousure?Yes,NoDisplayVolumeInfo.DisplayVolumeInfoinRaidSelectVolumeToDisplaySB-2805SAeriesViewDriveInformationSelectTheDrivesCreatePassThroughDiskSelectTheDrivesModifyPassThroughDiskSCSIChannel,SCSIID,SCSILUN,CacheMode,TagQueuing,MaxSyncRatePhysicalDrivesSelectTheDrivesSCSIChannel,SCSIID,SCSILUN,CacheMode,TagQueuing,MaxSyncRateDeletePassThroughDiskSelectTheDrivesDeletePassThroughYes,NoAreyousure?Yes,NoIdentifySelectedDriveSelectTheDrivesMuteTheAlertBeeperAlertBeeperSettingYes,NoDisabled,EnabledSaveTheSettingsYes,NoChangePasswordEnterNewPasswordRe-EnterPasswordSaveThePasswordJBOD/RAIDFunctionRAID,JBODConfiguredASJBOD?Yes,NoYes,NoRaidSystemFunctionAreyousure?Yes,NoRaidRebuildPriorityUltraLow(5%),Low(20%),Medium(50%),High(80%)SaveTheSettingsYes,NoTerminalPortConfigBaudRate1200,2400,4800,9600,19200,38400,57600,115200StopBits1bit,2bitsUpdateFirmwareRestartControllerYes,NoAreyousure?Yes,NoEthernetConfigurationDHCPFunctionLocalIPAddressDisabled,EnabledViewSystemEventsShowSystemEventsClearEventBufferClearEventBufferYes,NoHardwareMonitorTheHardMonitorInformationSystemInformationTheSystemInformationSB-2805SAeries4、创建RAID级别:1、输入密码八个0000002、选择QuickVolume/Raidsetup3、选择(RAID)级别Raid5或者Raid5+spare4、选择selectedcapacity5、选择selectstripesize——4K、8K、16K、32K、64K、128K6、选择createvolraidset7、选择Yey5.WebBase操作界面使用者可另外连接网络在远端利用网际浏览器作更详细之显示与操作。5.1如何连接网际浏览器SB-2805SA的预设IP是192.168.001.100,DHCP是enable,请先在LCD显示设定面板上或终端机上设定正确的IPSB-2805SA的预设的使用者名称是admin,密码是8个0。6、设定6.1快速设定QuickCreateSB-2805SAeries1.选选左方的QuickCreate进入快速设定画面,系统会自动检测到您所连接的硬盘数量。2.选择所需RAIDlevel。3.设定所需做RAID的容量。4.选择执行时的模式。5.选择StripeSize大小。6.选选ConfirmTheOperation后,按Submit执行RAID设定。SB-2805SAeries7、设定RaidSet功能7.1CreateRaidSet1.选选左方的CreateRaidSet,会进入“SelectTheIDEDriveForRAIDSet”画面,系统会自动检测到您所连接的硬盘。2.设定RaidSetName(最多15个字节),预设的RaidSetName以RaidSet#显示。3.选选ConfirmTheOperation后,按Submit执行RaidSet设定。SB-2805SAeries7.2DeleteRaidSet1.要删除RaidSet,选选左方的DeleteRaidSet,会进入“SelectTheRAIDSettoDelete”画面,系统会自动检测到现有的RaidSet并显示在画面上。2.选择所要删除的RaidSet。3.选选ConfirmTheOperation后,按Submit执行删除RaidSet的设定。7.3ExpandRaidSet1.要把新增的硬盘加入RaidSet中,选选左方的ExpandRaidSet,并选择所要扩充的RAIDSet,按Submit。SB-2805SAeries2.选择要加入RaidSet的硬盘。3.选选ConfirmTheOperation后,按Submit执行扩充RaidSet的设定。Note:1.当扩充RaidSet的设定一旦执行,即不可中断,必须完成执行。2.当扩充RaidSet的设定执行时,如有硬盘损坏的硬盘在系统中时,则当扩充RaidSet的设定执行完成后,会执行自动重建(autorebuild)程序。7.4ActivateIncompleteRaidSet当有硬盘在系统不通电的状态下被移除时,RaidSet的状态会变更为未完成(Incomplete)。如使用者要在系统通电时能继续使用,则可执行ActivateIncompleteRaidSet的选项,当执行完ActivateIncompleteRaidSet后,RaidSet的状态会变更为Degraded1.选选左方的ActivateRaidSet,会进入“SelectTheRAIDSettoActivate”画面,系统会自动检测到现有的RaidSet,并显示在画面上。2.选择所要的RaidSet。3.按Submit执行ActivateRaidSet的设定。SB-2805SAeries7.5CreateHotSpare当使用者要执行CreateHotSpare选项时,则所有未设定RaidSet的硬盘均会显示在画面中。选选ConfirmTheOperation后,按Submit执行