XXX生产楼消防设施改造工程施工方案XXX公司2015年12月25日目录2第一节编制依据..................................................................................................3第二节工程概况..................................................................................................42.1工程内容概况............................................................................................52.2工艺设计概况............................................................................................52.3施工特点....................................................................................................62.4施工难点....................................................................................................62.5施工重点....................................................................................................6第三节施工组织及目标......................................................................................73.1施工组织机构............................................................................................83.2工程施工目标管理....................................................................................8第四节主要施工方法..........................................................................................94.1火灾自动报警联动工程..........................................................................104.2七氟丙烷灭火系统..................................................................................13第五节施工协调配合管理................................................................................145.1施工协调原则..........................................................................................145.2尊重业主,服从监理..............................................................................14第六节工程施工进度计划及保证措施............................................................166.1工程施工进度计划..................................................................................166.2工程进度保证措施..................................................................................166.3主要材料供应计划..................................................................................166.4工程施工机具及设备计划......................................................................176.5劳动力计划(高峰期)..........................................................................18第七节工程质量保证措施................................................................................197.1质量目标..................................................................................................197.2工程质量保证组织机构..........................................................................197.3工程质量控制点设置..............................................................................197.4工程质量检测控制..................................................................................197.5工程质量不合格的处理..........................................................................2137.6工程质量施工过程控制措施..................................................................217.7质量回访及保修......................................................................................23第八节安全文明施工措施................................................................................248.1安全文明施工方针..................................................................................248.2安全施工管理..........................................................................................248.3文明施工管理..........................................................................................25附:项目组织机构图………………………………………………………………27施工进度计划图………………………………………………………………28第一节编制依据41.1施工图及相关技术资料。1.2国家和地方有关的法律、法规。1.3采用的标图和技术标准、规范、规程。1.3.1规范规程:《建筑电气工程施工质量验收规范》GB50303-2002《火灾自动报警系统施工及验收规范》GB50166-2007《气体灭火系统施工及验收规范》GB50263-2007《建筑设计防火规范》GB50016-2014《建筑施工安全检查标准》JGJ59-2011《施工现场临时用电安全技术规范》JGJ46-20051.3.2标准图集《室内管线安装》D(三)合订本《火灾报警及消防控制》04X501《火灾自动报警系统设计规范图示》14X505-1《住宅智能化电气设计施工图集》96SX501《智能建筑弱电工程设计施工图集》97X7001.3.3质量评定标准:《建筑工程施工质量验收统一标准》GB50300-20131.4工程施工合同1.5公司《质量体系文件》第二节工程概况52.1工程内容概况因现有火灾自动报警系统经多年使用,设备元件已经老化,消防控制主机整体报故障,且性能已经不能满足现行消防规范要求,应重新更换火灾自动报警系统设备,并依据现行消防规范完善其设备功能,以达到通过消防验收条件;本工程按照规范在各层相关部位设置火灾应急广播系统扬声器,火灾应急广播系统的扬声器与公共广播系统的扬声器公用;本建筑内应设置消防专用电话系统,以保证火灾期间消防控制室与各消防相关设备间的直接通讯。在消防值班室设置消防专用电话主机,除在各层的手动报警按钮处设置消防专用电话插孔外,在油机房、变配电间、电梯房处,设置消防专用电话分机;火灾自动报警系统中的显示设备、消防通信设备等的交流电源的备用电源由设备厂商配套供应UPS装置供电;四层两间机房需增设气体灭火系统。具体主要内容:a、火灾自动报警系统及消防联动控制系统安装、调试;b、四层机房气体灭火系统安装、调试;c.火灾应急广播系统、消防专用电话系统、消防专用电源安装调试。2.2工艺设计概况2.2.1火灾自动报警及消防联动控制疏散通道和公式场所设置感烟探测器、感烟感温探测器、消火栓按钮、带电话插孔式手动报警按钮、吸顶火警扬声器及种类输入输出模块。除图纸中说明及室内有吊顶外,火灾自动报警系统管线均采用明敷方式。62.2.2机房增设柜式七氟丙烷气体灭火系统,本设计采用全淹没灭火系统的灭火方式,灭火系统的控制方式为自动、手动及应急启动三种控制方式。2.3施工特点本工程涉及正在营业及办公的公共场所,施工难度大,配合协调要求高。该工程边营业边施工,要求施工不影响营业。与业主物管、办公室、营业厅的配合协调非常重要。消防设施安装完毕后负责恢复原有装修。2.4施工难点安全生产和文明施工异常严格。首先是文明施工,施工场所严格控制噪声排放、垃圾清运。控制施工和噪声不影响正常营业。人流多的空间按排人流量较少时段施工,并及时恢复原状。噪声大的作业按排在业主允许的时间区间。施工垃圾需及时清理、清运。材料垂直运输需避免碰撞、刮花电梯轿箱,水平运输需避免碰撞、刮花精装修的地板、墙身、天花等,现场基本没有材料堆放及稍大的机具存放位置。再者许多设备需安装在墙体内或天花内。施工时要求尽量减少对墙体或天花的拆卸,空间局限,施工难度高,工效低。2.5施工重点2.5.1施工策划,总体策划及局部策划。总体策划主要体现在施工组织设计。局部策划针对每一施工环节、施工空间进行,体现在施工过程的技术交底。局部策划包括:对原施工图竣工图了解,特别是系统图的熟悉,现场状况勘察,临设准7备、劳动力按排、材料机具准备、安全文明措施准备、技术交底等。2.5.2现场协调。施工面广而散,施工前必须与物业公司、办公室、大厅协调好。重点为一、二层营业厅区域,五、六层办公室区域。交流双方的要求信息,达成共识,主要是施工时间、施工过程中双方的配合工作。2.5.3施工安全。在营业环境下施工处处存在危险源