温度•温湿度•差压•风速•风量手持式测量仪•传感变送器•电子式记录仪•液柱式差压计差压量程...............................................请见选型表测量单位...............................................Pa,mmHO,mbar,inWG,mmHg(CP101和CP102)2mbar,inWG,mmHg,KPa,psi(CP103和CP104)精确度...................................................±1.5%读值±3Pa(CP101)±1.5%读值±3mmHO(CP102)2±1.5%读值±3mbar(CP103和CP104)响应时间...............................................0.3秒(可达到63%)分辨率.......................1Pa,0.1mmHO,0.01mbar,0.01inWG,0.01mmHg(CP101和CP102)21mbar,0,1inWG,1mmHg,0.1KPa,0.1psi(CP103和CP104)自动归零...............................................手动按键气体种类...............................................空气和中性气体额定过压...............................................25000Pa(CP101),7000mmHO(CP102)21400mbar(CP103),3000mbar(CP104)•微差压变送器−型号:CP100•量程从0...+100Pa至-1000...+2000mbar(依型号而定)•变送器可设置输出量程和零点量程置中•0...10V或4...20mA输出信号,主动输出,电源供应24Vac/Vdc(3/4线式)或4...20mA输出信号,被动输出,电源供应18...30Vdc(2线式)•ABS工业塑料,IP65外壳防护等级,可选变送器有或无显示屏•旋转式背板固定架可快速且简易地安装有或无显示屏微差压变送器CP100100mm93mm42mm外型尺寸图(包含墙面安装固定背板)选型表可依需求在以下选型表中选择所需之型号CP10A主动或•24Vac/Vdc•0-10V4-20mA差压量程变送器种类/电源供应/输出信号O含显示屏选型举例:CP103-AO型号:差压变送器CP100,量程-250...+500mbar,主动式信号输出0...10V或4...20mA输出信号,含显示屏-若需改变输出信号对应范围,请参考产品设置功能说明显示屏变送器规格外壳功能材质......................................................ABS工业塑料阻燃等级...............................................UL94-HB认证尺寸......................................................请见外壳尺寸图防护等级...............................................IP65显示屏...................................................5位LCD,尺寸50x15mm显示屏数字高度....................................10mm压力接口...............................................倒刺接口(直径)Ø6.2mm(CP101和CP102)耐压接口Ø4x6mm(CP103和CP104)电缆接入口...........................................电缆最大Ø7mm重量......................................................145g(含显示屏),110g(无显示屏)技术规格输出信号/电源供应................主动输出0...10V或4...20mA(电源供应24Vac/Vdc±10%),3/4线式被动输出4...20mA(电源供应18...30Vdc),2线式最大阻抗:500Ω(4...20mA)最小阻抗:1000Ω(0...10V)功耗......................................................2VA(0...10V)或最大22mA(4...20mA)电磁兼容性...........................................EN61326接线槽..................................................螺丝接线槽用于最大电缆Ø1.5mm²电脑通讯...............................................KIMORS232电缆工作温度...............................................0...+50°C储藏温度...............................................-10...+70°C环境......................................................空气和中性气体法国KIMO仪器(010)8465-2840•Fax:(010)8465-2037•E-mail:kimo_inst@126.com4-1000...+2000mbar1-500...+1000Pa2-500...+1000mmHO23-250...+500mbarP被动•18/30Vdc•4-20mAN无显示屏aGND......(-)接地VdcP.....(+)直流电压a输出信号0...10VIdcP......GND......(+)直流电流(-)接地a输出信号4...20mAVdc......GND....(+)直流电压(-)接地b电子接线图变送器接线工作必须由相关技术人员执行◦当进行接线时,变送器须未接电源供应◦!或c直流电源供应Vac.......Vac.......交流电压(相线)交流电压(中性线)b交流电源供应DIP切换键d电缆接入口c使用LCC100软件连接至电脑e压力接口(图示为高压用接口)电源接线槽b输出信号接线槽a4线式-+-+GNDVdcP-++-电源供应接线槽输出信号接线槽VdcGND电源供应24VdcVacVac电源供应24VacClasseII~~~~+IdcP+-输出信号4...20mA3线式+GNDVdcP-++VdcGND+GNDVdcPVacGND~PhaseNeutral+IdcP+IdcP-++-VdcIP电源供应18...30Vdc2线式-++-Vdc+IinVdc......IP..........(+)(-)a4线式3线式3线式2线式2线式-+++IP-输出信号4...20mA或0...10V-+-差压测量自动归零接线槽CP-AO和CP-AN•输出0...10V或4...20mA-主动输出101102103104101102103104或型号种类:输出信号接线槽CP-PO和CP-PN•输出4...20mA-被动输出101102103104101102103104型号种类:法国KIMO仪器•输出0...10V或4...20mA-主动输出101102103104101102103104型号种类:输出信号0...10V或或显示仪或PLC/BMS被动显示仪或PLC/BMS被动电缆接入口:在穿入电缆前须切开软塞显示仪或PLC/BMS被动或显示仪或PLC/BMS主动!若使用3线式接线,在供应电源至变送器前必须将输出接地端连至电源接地端◦请见下图◦输出信号接线槽电源供应接线槽电源供应24Vdc或输出信号接线槽电源供应接线槽输出信号4...20mA或0...10V电源供应24VacCP-PO和CP-PN•输出4...20mA-被动输出101102103104101102103104型号种类:法国KIMO仪器变送器设置设置变送器前,请卸下外壳上的2个螺丝,再将外壳打开◦请小心地依照图中DIP切换键指示设置若设置错误时,变送器的显示屏将出现以下提示“CONFERROR”.若发生时,你将停止变送器电源供应,在正确地设置DIP切换键后,再开启变送器电源◦◦使用DIP切换键设置变送器电路板上的DIP切换键说明DIP切换键1DIP2切换键1234}量程设置标准量程或零点置中设置1234}单位设置输出信号•输出信号设置DIP切换键1设置种类4...20mA0...10V切换键位置12341234•单位设置DIP切换键1PammH2OmbarinWGmmHG12341234123412341234KPaPSI12341234CP101和CP102CP103和CP104xxxxxxxxxx电路板DIP切换键d若需设置变送器时,必须未供应电源然后可依所需使用DIP切换键设置(如图示)◦当变送器设置完成后即可启动电源◦102103104102103104(适用于型号CP101-AO和CP101-AN)当进行自动归零时,请先取下连接的压力接口的软管并轻按自动归零按键◦差压测量自动归零12341234123412341234•量程设置DIP切换键2Pa1002505007501000mmH2O10.025.050.075.0100.0mbar1.002.505.007.5010.00inWG0.401.002.003.004.00mmHG0.802.004.006.008.002mmHO100.0250.0500.0750.01000.0Pa100025005000750010000mbar10.0025.0050.0075.00100.00inWG4.0010.0020.0030.0040.00mmHG8.0020.0040.0060.0080.00mbar100200300400500inWG40.080.0120.0160.0200.0Kpa10.020.030.040.050.0PSI2.04.06.08.010.0mmHG80160240320400mbar500750100015002000inWG200.0300.0400.0600.0800.0Kpa50.075.0100.0150.0200.0PSI10.015.020.030.040.0mmHG40060080012001600CP101举例:0----+750mmHO,量程为750mmHO22-500Pa----+500Pa,量程为1000PaCP102CP103CP104开-关切换!注意!•单标准量程/零点置中设置DIP切换键21234全量程1234零点置中若需设置其他量程,可使用较简单和方便的设置方式,请参考使用软件设置◦若需设置此种量程,将开-关(on-off)切换键4依照左图设置:举例:标准/0(0/100Pa)零点置中(-50Pa/0/+50Pa)可自行使用变送器内的切换键或软件连接电脑(接线图中的和)设置变送器的量程,单位,输出信号种类(依型号而定)ed设置种类切换键位置切换键位置当设置模拟输出信号种类时,请依照右图提示的开与关(on-off)切换键设置◦当设置测量单位时,请依照右图提示的开与关(on-off)切换键中的2,3,和4的对应使用单位设置◦.当设置量程时,请依照右图提示的开与关(on-off)