1高压电气设备电容量一览表交联聚乙烯电缆每公里电容量电缆导体截面积(平方毫米)电容量(uF/Km)YJV、YJLV6/6KV、6/10KVYJV、YJLV8.7/10KV、8.7/15KVYJV、YJLV12/20KVYJV、YJLV21/35KVYJV、YJLV26/35KV1*350.2120.1730.1521*500.2370.1920.1660.1180.1141*700.2700.2170.1870.1310.1251*950.3100.2400.2060.1430.1351*1200.3270.2610.2230.1530.1431*1500.3580.2840.2410.1640.1531*1850.3880.3070.2670.1800.1631*2400.4300.3390.2910.1940.1761*3000.4720.3700.3190.2110.1901*4000.5310.4180.3520.2310.2091*5000.6030.4380.3880.2540.2321*6300.6670.4700.4160.2870.256电缆导体截面积(平方毫米)电容量(uF/Km)YJV、YJLV6/6KV、6/10KVYJV、YJLV8.7/10KV、8.7/15KVYJV、YJLV12/20KVYJV、YJLV21/35KVYJV、YJLV26/35KV3*350.2120.1730.1523*500.2370.1920.1660.1180.1143*700.2700.2170.1870.1310.1251*950.3100.2400.2060.1430.1353*1200.3270.2610.2230.1530.1433*1500.3580.2840.2410.1640.1533*1850.3880.3070.2670.1800.1633*2400.4300.3390.2910.1940.1763*3000.4720.3700.3190.2110.1903*4000.5310.4180.3520.2310.2093*5000.6030.4380.3880.2540.2323*6300.6670.4700.4160.2870.2562电缆导体截面积(平方毫米)电容量(uF/Km)YJV、YJLV64/110KVYJV、YJLV128/220KV3*2400.1293*3000.1393*4000.1560.1181*5000.1690.1243*6300.1880.1383*8000.2140.1553*10000.2310.1723*12000.2420.1793*14000.2590.1903*16000.2730.1983*18000.2840.2073*20000.2960.2153*22000.2213*25000.23260KV级全绝缘变压器的电容(PF)试品容量(KVA)类别63020003150630080001600高压-地270041004600590070008200低压-地420066007900100001100015300110KV中性点分级绝缘变压器的电容(PF)试品容量(KVA)类别500003150020000100005600高压-中压、低压、地1420011400870061504200中压-高压、低压、地2480011800132009600低压-高压、中压、地19300193001200094006800220KV级中性点非全级绝缘部分变压器的电容(PF)试品型号SETSL-63000SSPSL-120000SSPSL-240000类型高压-中压、低压及地121001350017050中压-高压、低压及地185001970023260低压-高压、中压及地182002360029940试品型号SETSL-240000SSPSL-360000SSPSL-1200003类型高压-中压、低压及地322303391038020中压-高压、低压及地23260低压-高压、中压及地224702379022160部分发电机的电容值类别型号生产厂家额定容量(MW)额定电压(KV)相电容(uf)汽轮发电机QFS-125-2上海电机厂12513.80.08-0.12QFSN-200-2哈尔滨电机厂20015.750.19-0.21QFQS-200-2东方电机厂20015.750.1928-0.21QFQS-200-2北京重型电机厂20015.750.18-0.19QFS-300-2上海电机厂30018.00.16-0.20QFSN-300-2上海电机厂30018.00.18-0.20ATB-2美国GE公司35223.00.268(设计值)TBB-320-2(前苏联)32022.00.312-105*234美国西屋公司60020.00.2(工厂试验值)50WT23E-138ABB60022.00.253(设计值)水轮发电机72.5-8510.50.69430015.751.7-2.540018.02-2.5十、附录二:部分设备试验电压标准:电缆30-75Hz的交流耐压试验电压电缆额定电压交接试验电压预防性试验电压U。-U倍数电压值(KV)倍数电压值(KV)1.8/32U。3.61.6U。33.6/62U。7.21.6U。66/62U。121.6U。106/102U。121.6U。108.7/102U。17.41.6U。1412/202U。241.6U。1921/352U。421.6U。34426/352U。521.6U。4264/1101.7U。1091.36U。87127/2201.4U。1781.15U。146变压器的交流耐压试验电压标准额定电压KV最高工作电压KV线端交流试验电压值KV中性点交流试验电压值KV全部更换绕组部分更换绕组或交接时全部更换绕组部分更换绕组或交换时1≤132.532.533.51815181566.9252125211011.5353035301517.5453845382023.0554755473540.585728572110126200170(195)9580220252.03603068572395336(200)(170)500550.06305368572680578140120发电机定子绕组交流耐压试验标准周期要求大修前(1)全部更换定子绕组并修好后的试验电压如下:容量KW或KVA额定电压UnV试验电压V小于1000036以上2Un+1000但最低为150010000及以上6000以下Un6000-18000Un+300018000以上按专门协议更换绕组后(2)大修前或局部更换定子绕组并修好后试验电压为:运行20年及以下者1.5Un运行20年以上与架空线路直接连接者1.5Un5运行20年以上不与架空线路直接连接者(1.3-1.5)Un说明:1、应在停机后清除污秽前热状态下进行。处于备用状态时,可在冷状态下进行。2、水内冷电机一般应在通水的情况下进行试验,进口机组按厂家规定。架空绝缘导线线路的电容电流经验值:0.62A/km架空裸导线线路的电容电流经验值:0.03A/km电缆线路的电容电流经验值:1A/km均是指额定电压为10KV