通力KDL32型控制柜慢车调试

整理文档很辛苦,赏杯茶钱您下走!

免费阅读已结束,点击下载阅读编辑剩下 ...

阅读已结束,您可以下载文档离线阅读编辑

资源描述

通力KDL32型控制柜慢车调试主机MX10-166-98由0改为1(参数装载/默认参数)defaultparameters(1=LOADdefaultparameters,2=clearNTSsetup)6-95改为0,(参数锁定)parameterslock(0=OPEN,1=LOCK)1-62改为0(消防类型)1-71=31-73=3(OSS功能)1-77=11-95=1(驱动用户界面,0=V3F25/-18并行通讯界面,1=V3F16/V3F25S串行通讯界面)注:1-95改1后必须断电重启,否则进入不了6菜单6-2=0.8m/s²(加速度)acceleration6-3=1.75m/s(额定速度)nominalspeed(elevatorspeed)6-4=1000KG(电梯额定载重)6-6=480mm(曳引轮直径)tractionsheavediameter6-7=2roping6-60=10.37(电机选型)motortype6-61=由1改为0brakevoltagereductionenable(1=enable)6-62=0(角度)torqueangleoffset(0=offsetnotset)注:若6-62不为0,则6-70角度不能定位6-63=2(电机左置,右置-2)resolverspeedandpolarity(旋转速度和极性6-65=2(电机左置,右置-2)encodertypeandpolarity(编码器类型和极性6-99=改1,参数保存(save)6-70=改1,再开电梯,角度自动定位(电机发出异响\震动,大概2-3秒,电梯停止,再开电梯,若运行正常则OK.查看6-62角度值),运行方向相反,换相序U、V,正常时,为U、V、W相对应。例:6-63=-2时,U、V对换。KDL32ParameterList6-06200Documentidentificationoftheparameterset(=thissheet)参数版本Elevatorparameters6-11.0-15.05.0Pfactor(proportionalgainofspeedcontroller)增益因数6-20.3-1.2m/s²0.6(0.8)acceleration加速度6-30.4-4m/s1.6(1.75)nominalspeed电梯额定速度6-4400-4000kg1000elevatorload额载6-6100-1000mm480tractionsheavediameter曳引轮直径6-71,2,4,62roping6-100.00-65.00%50balancing6-11400-9000kg1000carandslingmassAdditionalelevatorparameters6-200.1-0.5m/s0.3inspectionspeed检修速度6-210.05-2.00s0.25Ifactor6-220.25-3.20s1.20reducedspeed6-230.5-1.51.00starttorquescaling6-250.4-11.04KTW/Qfactor6-26-2.0-7.0kg/m0.0ropeweight6-270.00-5.00kg/m0.00carcableweight6-280-400mm80finaljerkdistance6-300-21braketest6-310-103tachofaultcounter6-320-80ms30speedfeedbackfiltertime6-330.01-2.0s0.35startdelay6-370.10-2.40calcjerk6-390.20-0.70m/s0.5ADOspeedSpecialparameters6-401.5-7.04.0torquelimlt6-520.1-2.4m/s²calcfullspeedjerk6-530-400mm150distanceadvanceMachineryparameters6-602.00-20.7510.37motortype6-610/11brakevoltagereductionenable6-620-360ºele0torqueangleoffset6-63+/-1,21resolverspeedandpolarity6-64500-300000encoderpuisespermotorround6-65+/-1,21encodertypeandpolarity6-663.0-8.5khz5.5PWMswitchingfrequency6-6790-140ºc100motortemperaturelimit6-6810.0-100.0A0.0motoroverloadfullspeedcurrent6-6910.0-100.0A0.0motoroverloadaccelerationcurrentCommissioningandtests6-700-10drivecommissioning编码器角度自动定位6-721-220enableelevatortest6-74-2-120%0LWDsetup称重6-751-2091realtimedisplaymonitorselection6-760.00-99.001.00EZOandvirtualfloorsetupMotordata6-80100-350V0电机额定电压6-8110.0-80.0A0.00电流6-8210.0-400.0HZ0.0频率6-8320-1500r/min0电机转速6-840.0-50.0kw0.0功率Permanentstore6-950,11parameterlock(0=open1=lock)参数锁定6-97oftwaraversions6-980,1,20defaultparameters(参数装载)6-990/10save(参数保存)快车调试3.1细调lwda)空载时,检查轿厢和轿底1wd的安装.b)电压表一极接1wd(+),一极接agnd(-)c)轿厢空载,调1wed至1.0v(+/-0.0lv),而且菜单5-1显示00d)50%载荷:调1wdf至2.5v(+/-0.0lv),而且菜单5-1显示50.e)打下rdf开关,拨出1wd插,检查lce菜单5-1的显示应低于-15%(如-20%)f)如果菜单5-1的显示大于-15%(如-2%),应增大称重感应器到感应片之间的距离,并重调.参看E—lineMinlSpace安装手册12.10章节.3.2SETUPa)将rdf拉下,驱动电梯至底层或稍低一点.检查lcecpu板上30,61:u,77:n,?7:s灯亮.b)技菜单5-2-l,蜂鸣响起:间歇的长音.rdf打上,电梯自动慢速向上.c)如果电梯中途停下,会显示故障代码(111---116)d)如果setup成功,将显示顶层楼楼层,电梯从Setup运行模式进入正常运行模式.

1 / 4
下载文档,编辑使用

©2015-2020 m.777doc.com 三七文档.

备案号:鲁ICP备2024069028号-1 客服联系 QQ:2149211541

×
保存成功