三坪新区排水工程混凝土质量缺陷修补方案编制:审核:审批:中铁一局集团市政环保工程有限公司兵团十二师三坪新区排水工程污水处理厂项目经理部二〇一六年七月兵团十二师三坪新区排水工程钢筋工程专项施工方案目录一、编制依据······································································································1二、工程概况······································································································1三、钢筋加工······································································································1四、钢筋连接与安装···························································································2五、钢筋质量控制要点·······················································································11六、钢筋现场验收······························································································16七、钢筋的成品保护··························································································17八、安全保证措施······························································································17兵团十二师三坪新区排水工程钢筋工程专项施工方案1一、编制依据1.《建筑工程施工质量验收统一标准》GB50300—20132.《混凝土结构工程施工质量验收统一标准》GB50204—20153.《钢筋焊接及验收规范》(JGJ18-2012)4.相应的国家现行技术标准5.《兵团十二师三坪新区排水工程施工图纸》6.《直螺纹钢筋机械连接质量标准卡控红线》股份按质(2013)083要求执行二、工程概况本工程为兵团十二师三坪新区污水处理厂工程,其中污水处理厂远期总规模为5.0万m³/d,近期总规模为2.0万m³/d,近期分一,二期建设。本工程完成一期工程1.0万m³/d建设,工程总征地面积为8.618ha,其中近期工程占地4.628ha。污泥脱水间及加药间,污泥缓冲池,总变配电室土建部分按远期总规模5.0万m³/d设计,设备按一期工程1.0万m³/规模设计,鼓风机房,紫外线消毒池土建部分按近期总规模2.0万m³/d设计,设备按一期工程1.0万m³/d规模设计;粗格栅间及污水提升泵房,细格栅间及旋流沉砂池土建和设备均按近期总规模2.0万m³/d设计;氧化沟,二沉池,絮凝沉淀池,滤池间土建和设备均按一期工程1.0万m³/d规模设计;明渠流量计土建和设备均按远期规模5.0万m³/d设计。本工程钢筋除HPB300以外的都必须是牌号带E的钢筋。三、钢筋加工(一)作业条件1.本工程钢筋采用集中加工方式,钢筋加工制作前,要将钢筋加工下料表与设计图复核,检查下料表是否有错误和遗漏,对每种钢筋要按下料表检查是否达到要求,经过这两道检查后,再按下料表放出实样,试制合格后方可成批制作,加工好的钢筋要挂牌堆放整齐有序。2.钢筋表面应洁净,无损伤,油渍、漆污和铁锈等,应在使用前清除干净,带有颗粒状或片状老锈钢筋不得使用。(二)施工工艺除锈→调直→切断→弯曲成形→加工检查质量兵团十二师三坪新区排水工程钢筋工程专项施工方案2(三)施工要求1.钢筋调直:用机械调直。经调直后的钢筋不得有局部弯曲、死弯、小波浪形。2.钢筋切断:钢筋切断应根据钢筋号、直径、长度和数量,长短搭配,先断长料后断短料,尽量减少和缩短钢筋短头,以节约钢材。3.钢筋弯钩或弯曲:1)钢筋弯折:钢筋做不大于90°的弯折时,弯折处的弯弧内直径不应小于钢筋直径的5倍。2)箍筋弯钩弯折角度焊接不应小于90°;对于抗震结构应为135°,平直部分不得小于箍筋直径的5倍,对于抗震结构不小于箍筋直径的10倍。4.钢筋下料长度应根据构件尺寸、混凝土保护层厚度、钢筋弯曲调整值和弯钩增加长度等规定综合考虑。1)直钢筋下料长度=构件长度-保护层厚度+弯钩增加长度。2)弯起钢筋下料长度=直段长度+斜弯长度-弯曲调整值+弯钩增加长度。3)箍筋下料长度=箍筋内周长+箍筋调整值+弯钩增加长度。5.钢筋加工的允许偏差,见下表:钢筋加工允许偏差表项目允许偏差/mm受力钢筋长度方向全长的净尺寸±10弯起钢筋的弯折位置±20箍筋内净尺寸±5四、钢筋连接与安装(一)钢筋连接施工工艺流程1.底部钢筋连接施工工艺流程1)基础底板钢筋:清理垫层→弹钢筋位置线→连接底板下层筋→放置马凳筋→连接上层横向筋→连接上层纵向筋→焊接支撑筋。2)墙板钢筋:兵团十二师三坪新区排水工程钢筋工程专项施工方案3清理墙根松动混凝土石子、浮浆及杂物→立竖筋→连接横竖筋。3)梁钢筋:支梁底模及侧模→在底模划箍筋间距线→主筋穿好箍筋,按已划好的间距逐个分开→固定弯起筋及主筋→穿次梁弯起筋及主筋并绑好箍筋→放主筋架立筋、次梁架立筋→隔一定间距将梁底主筋与箍筋绑住→绑架立筋→再绑主筋→放置保护层垫块,主次梁同时配合进行。2.主体结构钢筋连接施工工艺流程结构层面轴线、墙柱偏位钢筋调整墙柱钢筋连接墙柱箍筋连接楼面清扫验收(质检)同意下部模板支撑主次梁、板下部钢筋连接马镫固定板上部钢筋连接验收墙、柱预留插筋就位、固定验收。(包括轴线)1)柱、墙:外露筋调整钢筋附着物清除墙、柱根部清扫箍(水平)筋布置就位连接墙柱垫块验收。2)梁、板:模板清扫梁柱交叉处柱箍筋就位主梁筋连接次梁筋连接板下层筋马镫、水电管预埋板上层筋验收。(二)工艺、规范1.机械连接:直径大于或等于18的钢筋,接头采用直螺纹套筒连接,接头质量等级为Ⅱ级。凡钢筋接头处,接头位置应错开,同一连接区段内受拉钢筋接头面积百分率应小于50%,接头连接区长度为40d(d为受力钢筋的较大直径)。钢筋混凝土墙(壁)的拐角处(包括池壁与底板拐角处)的钢筋,应有足够的长度锚入相邻的墙(壁)内,锚固长度自墙(壁)的内侧表面算起,不小于40d(HPB300级钢筋不小于35d)且直线长度不小于20d,如果同一平面内,锚入相邻墙(壁)内一侧的并排钢筋超过两根时,应将靠墙(壁)内侧钢筋适当向里放置,以保证同一平面内一侧的并排钢筋不超过两根。2.焊接接头:直径小于18的纵筋采用电渣压力焊;凡钢筋接头处,接头位置应错开,同一连接区段内手拉钢筋接头面积百分率应小于50%,接头连接区段长度为40d(d为受力钢筋的较大直径),且不小于500mm。3.楼板通长筋如需接头,除接头形式特别注明外,则上部筋在跨中1/3区兵团十二师三坪新区排水工程钢筋工程专项施工方案4段搭接。相邻接头间距大于35d,对双层双向钢筋网片,除特别注明外,其短向钢筋在外侧,长向在内侧。4.框架梁内上部通长设置的纵筋如需接头,接头设在跨中,严禁采用电渣压力焊。(三)钢筋的现场连接与安装1.准备工作:1)核对成品钢筋的钢号、直径、形状、尺寸和数量等是否与配料单、料牌相符,如有错漏,应纠正整补。所示钢筋进场必须有生产合格证以及及时进行钢筋的检验合格记录方可使用。2)准备连接安装钢筋用铁丝、工具、设备、连接架等。3)准备好控制砼保护层用的垫块。4)清扫钢筋连接安装场地,在模板上或架立筋上用粉笔画出钢筋位置线,预埋件、预埋管线位置线。2.钢筋连接总体要求:1)所有梁、板、墙、柱的受力主筋、箍筋、钢筋网均按设计图纸的要求设置,箍筋的弯钩叠合处沿受力钢筋方向错开设置。2)钢筋的交叉点均采用双股22号铅丝扎牢。3)钢筋弯钩平面与模板面垂直,转角处钢筋弯钩平面与模板夹角为模板转角的平分角。当采用插入式振捣器浇筑小型截面柱时,弯钩平面与模板的夹角不得小于15°。4)受力钢筋接头位置设在受力较小处,接头互相错开,当采用非焊接的搭接接头时,从任一接头中心至1.3倍搭接长度的区段范围内,或当采用焊接接头时,在任一焊接接头中心至钢筋的一个锚固长度且不小于500mm的区段范围内,同一根钢筋不得有两个接头。3.板钢筋连接安装:1)板的钢筋在施工前先搭好排架,铺好底模,连接前准确测量墙柱轴线及模板控制线并作好标记。2)板的底部钢筋伸入支座≥10d且不小于120mm。3)板支座上部钢筋(负筋)两端设直钩,边支座负筋伸入梁内满足锚固长兵团十二师三坪新区排水工程钢筋工程专项施工方案5度。4)楼板配筋图中板中负筋下所注数字表示伸出梁边的长度双向楼板底筋短跨钢筋放于下排。5)板跨度大于或等于4米时,模板按跨度0.2%起拱。6)所有钢筋要搭接接长时,在同一截面接头的钢筋截面积不得超过钢筋总面积的25%。7)相邻板跨中正筋规格和间距相同时应尽可能连通配置。楼板配筋图中未画出分布筋见具体设计8)构筑物施工时采用的拉筋,墙板用φ8@600X600布置,9)布置马凳筋:板厚大于400时,为Φ14@800X800,不允许埋有露头钢筋,以免造成池体的漏渗,如无法避免,应采取有效防水措施,加焊止水片。10)板的分布筋,图中注明外均为φ6@200。4.框架梁、次梁钢筋连接安装:1)框架梁、次梁钢筋的接头选择在受力较小的位置。梁上部通长钢筋可选择在跨中1/3净跨范围内搭接。相邻两跨的下部钢筋当直径、位置相同时,钢筋通长,此时通长钢筋可选择在支座处接长。2)梁钢筋连接采用满扎,扎点相互间呈“八”字形错开。梁箍筋除单肢箍外,其余箍筋采用封闭形式,制作成135°弯钩,当梁的上部钢筋为多排时,须注意主筋与箍筋连接牢固。3)梁跨度大于或等于4米时,模板按跨度0.2%起拱,悬臂梁按悬臂长度0.4%起拱,起拱高度不小于20mm。4)构造柱与梁连接或在梁上立柱,梁上预先留出柱子钢筋。5)梁平法施工图中主次梁交接处,未注明根数的附加箍筋为:次梁每册3排,间距50mm,箍筋直径及肢距同所在梁。梁上设柱,梯柱处设附加箍筋同前述。图中未注明的附加吊筋均为2Φ16,且同时设置附加箍筋。6)框架梁内上部通长设置的纵筋如需接头,接头设在跨中,严禁采用电渣压力焊7)简支梁和连续梁简支端的下部受力钢筋深入制作的锚固长度不小于12d。8)梁受扭纵筋按受拉筋锚入支座内,弯起钢筋平段锚固长度在受拉区不应兵团十二师三坪新区排水工程钢筋工程专项施工方案6小于20d,受压区不应小于20d。9)因梁及板的钢筋规格较多,故在施工前,由专人负责核对钢筋的钢号、直径、形状、尺寸和数量,如有差错,要及时纠正增补,在连接复杂的结构部位时,研究逐根钢筋穿插应就位的顺序,并与模板工程联系,确定支模和连接钢筋的先后次序,避免返工和不必要的连接难度。10)在梁纵向受力钢筋采用双层排列时,两排钢筋之间垫以直径≥25mm的短钢筋,以保持其设计距离。箍筋的接头(弯钩叠合处)交错布置在两根架力钢筋上。11)梁交叉节点处钢筋穿插十分稠密时,留出振动棒头子插入空隙,以利浇筑砼。平板钢筋连接前必须按图纸划出钢筋间距位置线,尽量做到纵横向一条线。5.墙、柱钢筋连接安装:1)墙柱竖向钢筋接头一般在楼板面以上每隔一根错开接头,第一次接头距楼板面或基础顶面≥1/3Hn(Hn为所在楼层的柱净高),相邻纵筋交错≥Lae。2)柱箍筋一般为复合箍,由大箍和中小箍或拉结钢筋组成,除拉结钢筋外均采用封闭形式,并作成135°弯钩;箍筋的接头(弯钩叠合处)交错布置在