轻钢龙骨施工方案(定稿)

整理文档很辛苦,赏杯茶钱您下走!

免费阅读已结束,点击下载阅读编辑剩下 ...

阅读已结束,您可以下载文档离线阅读编辑

资源描述

青建集团股份公司施工方案山东省第23届运动会综合指挥中心工程轻钢龙骨墙板施工方案(B—QL01)批准:审核:编制:青建集团股份公司房建二分公司二O一二年四月目次一.工程概况···················································2二.施工准备···················································21.材料准备····················································22.主要机具····················································23.作业条件····················································24.施工工艺····················································35.质量标准····················································96.施工试验计划···············································107.安全生产、现场文明施工要求··································108.成品保护···················································109.工程质量验收···············································1010.主要工程质量通病治理措施·································1011.编制依据··················································1112.节点详图··················································11一.工程概况:本工程为济宁综合指挥中心轻钢龙骨墙板安装项目。其中轻钢龙骨纸面石膏板120厚为设计基准,主要用于地上普通用房,如办公室、会议室、备用房间等房间隔墙。双面双层内填50厚岩棉(12+12+75+12+12)其中用于会议室等有隔声要求的房间,要求空气声隔声标准(A声级)大于50dB。墙体的耐火极限应满足1小时。轻钢龙骨埃特板(硅酸钙板)隔墙120厚为设计基准,主要用于卫生间、清洁间、淋浴间等有水的房间,双面单层内填50岩棉的做法(10+100+10),独立的或者与卫生间相邻的开水间维护墙体使用硅酸钙板隔墙。有水房间与无水房间之间的隔墙采用一面单层埃特板(硅酸钙板)一面双层纸面石膏板(10+100+12+12)。由于一、二层层高超过5米,按图集《8BJ2-5(88J)墙身-轻钢龙骨纸面石膏板(2007)》常规做法不能保证墙身稳定性,等需等设计出专门加固方案,本方案仅适用二层以上部位的轻钢龙骨隔墙的施工。二.施工准备:1.材料准备:1.1轻钢龙骨:目前隔墙工程使用的轻钢龙骨主要有支撑卡系列的通贯龙骨,品牌为龙牌或亿博。轻钢龙骨主件有沿顶沿地龙骨、加强龙骨、竖(横)向龙骨、横撑龙骨。轻钢龙骨配件有支撑卡、卡托、角托、连接件、固定件、护角条、压缝条等。轻钢龙骨的配置应符合设计要求。龙骨应有产品质量合格证。龙骨外观应表面平整,棱角挺直,过渡角及切边不允许有裂口和毛刺,表面不得有严重的污染、腐蚀和机械损伤。1.2紧固材料:M8膨胀螺栓、镀锌自攻螺丝(单层l2mm厚纸面石膏板/10mm硅酸钙板用25mm长螺丝,两层12mm厚纸面石膏板用35mm长螺丝)等,应符合设计要求。1.3填充材料:50厚岩棉等按设计要求选用。1.4纸面石膏板、埃特板(硅酸钙板):纸面石膏板应有产品合格证,品牌为龙牌、亿博或者泰山。本工程采用12厚纸面石膏板和10厚埃特板(硅酸钙板)。1.5接缝材料:接缝腻子、玻纤带(布)、108胶。1.5.1接缝腻子:抗压强度>0.3MPa,抗折强度>1.5MPa,终凝时间>0.5h。1.5.250mm中碱玻纤带和玻纤网格布:布重>80g/m2断裂强度:25mm×100mm布条,经向>300N,纬向>150N。2.主要机具板锯、电动剪、电动自攻钻、电动无齿锯、手电钻、直流电焊机、刮刀、线坠、靠尺等。3.作业条件3.1主体结构已验收。3.2室内弹出+100cm标高控制线。3.3熟悉图纸,并向作业班组作详细的技术交底。3.4根据设计图和提出的备料计划,检查隔墙全部材料,使其配套齐全。安装各种系统的管、线盒及其他准备工作已到位。3.5主体结构墙为砖砌体时,应在隔墙交接处,按1000mm间距预埋防腐木砖。3.6先作样板墙一道,经鉴定合格后再大面积施工。4.施工工艺4.1工艺流程图1轻钢龙骨隔墙施工流程4.2弹线、分档在隔墙与上、下及两边基体的相接处,应按龙骨的宽度弹线。弹线清楚,位置准确。按设计要求,结合罩面板的长、宽分档,以确定竖向龙骨、横撑及附加龙骨的位置。图2龙骨布置示意4.3踢脚部位处理由于室内三层以上地面建筑做法仅50,为了保证100高踢脚做法,取消地枕,在结构面设置方钢管将地龙骨抬起,在踢脚板高度范围内设防腐处理后的9厘板作为黏贴100高踢脚板的基层,详图3148123100100双层12mm厚纸面石膏板刮腻子乳胶漆饰面蝴蝶卡穿心龙骨岩棉地砖踢脚线九厘板防腐涂料2遍双层12mm厚纸面石膏板刮腻子乳胶漆饰面蝴蝶卡穿心龙骨岩棉地砖踢脚线九厘板防腐涂料2遍C100系列隔墙龙骨@400mmC75系列隔墙龙骨@400mmC100系列天地龙骨C75系列天地龙骨?8mm膨胀螺栓C100系列隔墙大样图SC1:5C75系列隔墙大样图SC1:5?8mm膨胀螺栓40X60*3mm镀锌方管40X40X4镀锌角钢固定于方管两侧@600mm40X60*3mm镀锌方管方管固定平面图SC1:540X40X4镀锌角钢固定于方管两侧@600mm40X60*3mm镀锌方管40X60*3mm镀锌方管?8mm膨胀螺栓?8mm膨胀螺栓40X40X4镀锌角钢固定于方管两侧@600mm40X40X4镀锌角钢固定于方管两侧@600mm详图3踢脚线细部处理4.4沿顶、沿地固定龙骨按弹线位置固定沿顶、沿地龙骨,可用M8*50膨胀螺栓固定,固定点间距600mm,龙骨对接应平直。细部处理见图3和图4.图4无吊顶房间隔墙顶部处理图5有吊顶房间顶部处理4.5固定边框龙骨沿弹线位置固定边框龙骨,龙骨的边线应与弹线重合。龙骨的端部应固定,固定点间距应不大于1000mm,固定应牢固。边框龙骨与基体之间,应按设计要求安装密封条。4.6选用支撑卡系列龙骨时,应先将支撑卡安装在竖向龙骨的开口上,卡距为400~750mm,龙骨两端的距离为25mm。4.7安装竖向龙骨应垂直,其中卫生间(贴面砖墙体)部位竖向龙骨间距300mm,其它房间竖向间距400mm4.8选用通贯系列龙骨时,低于3000的隔墙宜安装1道,3000-5000高的隔墙宜安装2道,5000以上的宜安装3道。4.9罩面板横向接缝处,如不在沿顶、沿地龙骨上,应加横撑龙骨固定板缝。4.10门窗及转角节点处,其他薄弱点为保证墙体稳定性,需进行加固处理。门框采用单独方钢管门框系统,详附图:图6门窗顶部龙骨连接构造双层12mm厚纸面石膏板刮腻子乳胶漆饰面C75系列隔墙龙骨@400mm80*40*2.5mm镀锌方管焊接于两侧竖向方管C75系列天地龙骨固定于两侧竖龙骨岩棉成品门套123C75系列隔墙门梁大样图SC1:5123双层12mm厚纸面石膏板刮腻子乳胶漆饰面岩棉C75系列隔墙龙骨@400mm80*40*2.5mm镀锌方管焊接于横向方管成品门套C75系列隔墙门框大样图SC1:59厘板防火处理2遍9厘板防火处理2遍80*40*2.5mm镀锌方管固定于底板与顶板80*40*2.5mm镀锌方管焊接于两侧竖向方管C75系列门框加固处理双层12mm厚纸面石膏板刮腻子乳胶漆饰面C100系列隔墙龙骨@400mmC100系列天地龙骨固定于两侧竖龙骨岩棉100*50*3.5mm镀锌方管焊接于两侧竖向方管9厘板防火处理2遍成品门套148C100系列隔墙门梁大样图SC1:5148双层12mm厚纸面石膏板刮腻子乳胶漆饰面岩棉C100系列隔墙龙骨@400mm100*50*3.5mm镀锌方管焊接于横向方管成品门套C100系列隔墙门框大样图SC1:5注:所有钢材切割、焊接处防锈处理。9厘板防火处理2遍100*50*3.5mm镀锌方管固定于底板与顶板100*50*3.5mm镀锌方管焊接于两侧竖向方管C100系列门框加固处理4.11对于特殊结构的隔墙龙骨安装(如曲面、斜面隔墙等),应符合设计要求。4.12电气铺管、安装附墙设备按图纸要求预埋管道和附墙设备。要求与龙骨的安装同步进行,或在另一面石膏板封板前进行,并采取局部加强措施,固定牢固。电气设备专业在墙中铺设管线时,应避免切断横、竖向龙骨,同时避免在沿墙下端设置管线。4.13龙骨检查校正补强安装罩面板前,应检查隔断骨架的牢固程度,门窗框、各种附墙设备、管道的安装和固定是否符合设计要求。如有不牢固处,应进行加固。4.14安装石膏/埃特板(硅酸钙板)罩面板(1)纸面石膏板/埃特板(硅酸钙板)宜竖向铺设,长边(即包封边)接缝应落在竖龙骨上。曲面墙所用纸面石膏板/硅酸钙板宜横向铺设。(2)龙骨两侧的纸面石膏板/埃特板(硅酸钙板)及龙骨一侧的内外两层纸面石膏板应错缝排列,接缝不得落在同一根龙骨上。(3)纸面石膏板/埃特板(硅酸钙板)用自攻螺钉固定。沿纸面石膏板/硅酸钙板周边螺钉间距不应大于200mm,中间部分螺钉间距不应大于300mm,螺钉与板边缘的距离应为10~16mm。(4)安装纸面石膏板时,应从板的中部向板的四边固定,钉头略埋入板内,但不得损坏纸面。钉眼应用石膏腻子抹平。(5)纸面石膏板/埃特板(硅酸钙板)宜使用整板。如需对接时,应紧靠,但不得强压就位。(6)隔墙端部的纸面石膏板/埃特板(硅酸钙板)与周围的墙或柱应留有3mm的槽口。施工时,先在槽口处加注嵌缝膏,然后铺板,挤压嵌缝膏使其和邻近表层紧密接触。(7)隔墙板的下端如用木踢脚板覆盖,罩面板应离地面20~30mm;用大理石、水磨石踢脚板时,罩面板下端应与踢脚板上口齐平,接缝严密。(8)铺放墙体内的玻璃棉、矿棉板、岩棉板等填充材料,与安装另一侧纸面石膏板/硅酸钙板同时进行,填充材料应铺满铺平。4.15接缝及护角处理(1)纸面石膏板/埃特板(硅酸钙板)墙接缝做法有3种形式,即平缝、凹缝和压条缝。一般做平缝较多,可按以下程序处理:1)纸面石膏板/埃特板(硅酸钙板)安装时,其接缝处应适当留缝(一般3~6mm),并必须坡口与坡口相接,接缝内浮土清除干净后,刷一道50%浓度的108胶水溶液。2)用小刮刀把WKF接缝腻子嵌入板缝,板缝要嵌满嵌实,与坡口刮平。待腻子干透后,检查嵌缝处是否有裂纹产生,如产生裂纹要分析原因,并重新嵌缝。3)在接缝坡口处刮约1mm厚的WKF腻子,然后粘贴玻纤带,压实刮平。4)当腻子开始凝固又尚处于潮湿状态时,再刮一道WKF腻子,将玻纤带埋入腻子中并将板缝填满刮平。5)阴角的接缝处理方法同平缝。(2)阳角可按以下方法处理:1)阳角粘贴两层玻纤布条,角两边均拐过100mm,粘贴方法同平缝处理,表面亦用接缝腻子刮平。2)当有部位做金属护角条时,按要求的部位、高度,先刮一层腻子,随即用镀锌钉固定金属护角条,并用腻子刮平。图7拐角墙细部处理图8十字交叉墙细部处理图8丁字墙墙细部处理4.16待板缝腻子干燥后,检查板缝是否有裂缝产生,如发现裂纹,必须分析原因,采取有效的措施加以克服,否则不能进入板面装饰施工。5质量标准5.1主控项目(1)骨架隔墙所用龙骨、配件、墙面板、填充材料及嵌缝材料的品种规格性能和木材的含水率应符合设计要求。有隔声、隔热、阻燃、防潮等特殊要求的工程材料应有相应性能等级的检测报告。检验方法:观察;检查产品合格证书

1 / 13
下载文档,编辑使用

©2015-2020 m.777doc.com 三七文档.

备案号:鲁ICP备2024069028号-1 客服联系 QQ:2149211541

×
保存成功