郑东新区热电有限公司一期2×200MW机组工程汽轮机调节保安系统试验措施河南第一火电建设公司调试所-1-编号:8080-HNHY-TSJ-A05-020河南第一火电建设公司调试所调试作业指导书工程名称:郑东新区一期2×200MW机组工程项目名称:汽轮机调节保安系统调试方案编制单位:河南第一火电建设公司调试所出版日期:2007年07月05日郑东新区热电有限公司一期2×200MW机组工程汽轮机调节保安系统试验措施河南第一火电建设公司调试所-2-工程名称郑东新区热电厂一期2×200MW机组工程文件名称汽轮机调节保安系统调试方案文件类别分系统\整套启动调试批准年月日审核年月日编制年月日郑东新区热电有限公司一期2×200MW机组工程汽轮机调节保安系统试验措施河南第一火电建设公司调试所-3-目录1目的···························································································(04)2依据···························································································(04)3设备系统简介···········································································(04)4调试内容及验评标准·······························································(08)5组织分工··················································································(08)6使用仪器设备··········································································(08)7调试应具备的条件··································································(08)8调试步骤··················································································(09)9联锁、保护定值······································································(15)10安全环境注意事项································································(16)郑东新区热电有限公司一期2×200MW机组工程汽轮机调节保安系统试验措施河南第一火电建设公司调试所-4-1目的为了更好地实施主机调节保安系统的投入,通过对该系统设备及相关系统调试,测取并初步确定相关特性,保证系统各参数正常,系统保护、联锁、信号正确,达到《火电工程调整试运质量检验及评定标准》所规定的要求,为机组创造安全、可靠的启动条件,特制订本方案。2依据2.1《火力发电基本建设工程启动及竣工验收规程(1996年版)》。2.2《火电工程启动调试工作规定》。2.3《火电工程调试质量检验及评定标准(1996年版)》。2.4《电力建设施工及验收技术规范》。2.5《火电机组达标投产考核标准(2001年版)》。2.6《电力建设安全健康与环境管理工作规定(2002年版)》。2.7《工程建设标准强制性条文(电力工程部分)》。2.8国家及行业有关技术规范、标准。2.9设计、制造技术文件、资料。2.10相关的合同文件、纪要。3设备系统简介3.1系统概述郑东新区热电有限公司2×200MW汽轮机发电机组的调节保安系统采用由东方汽轮机厂生产的DEH控制系统,低压保安系统,高、低压接口装置,高压抗燃油系统及汽轮机安全监视保护系统等机械和液压部套等组成。调节保安系统压力油由EH油系统的高压油提供。机组调节保安系统的作用是控制机组的转速、抽汽压力,从而保障机组的稳定运行,并可以调整电负荷或热负荷的大小。在异常情况发生时,迅速关闭各进汽阀,遮断机组进汽,实现紧急停机。汽轮机调速系统是由测速元件(或测功元件)、放大元件、执行元件及调节对象(汽轮机转子)四部分组成的带负反馈的自动调节系统。不论是单机运行还是并网运行,它都能根据转速(或功率)自动调整汽门开度以适应外界负荷的变化。郑东新区热电有限公司一期2×200MW机组工程汽轮机调节保安系统试验措施河南第一火电建设公司调试所-5-3.2基本功能3.2.1挂闸。3.2.2适应高中压缸启动的要求及具有中压缸启动的功能。3.2.3具有超速限制的功能。3.2.4需要时,能够快速、可靠的遮断汽轮机进汽。3.2.5适应阀门活动试验的要求。3.2.6具有超速保护的要求,机械式超速和电气超速。3.3有关设备及部套简介3.3.1危急遮断器危急遮断器是汽轮机重要的超速保护部套。其主要由壳体,撞击子,和弹簧组成。转配时撞击子重心偏离旋转中心6.5mm。当汽轮机转子转速低于危急遮断器的动作转速时,撞击子产生的离心力小于弹簧的预紧力,撞击子不动作;当汽轮机转速升到110-112%额定转速时,危急遮断器的撞击子在离心力的作用下迅速击出,保安油泄掉,从而使主汽阀、调节阀迅速关闭。为提高可靠性,防止危急遮断器的卡涩,运行时借助遮断隔离阀组、复位试验阀组,可完成喷油试验及提升转速试验。调整危急遮断器弹簧的预紧力可改变动作转速。3.3.2手动停机机构系统在机头设有手动遮断阀供紧急停机用。手按下遮断阀按钮,使危急折断器动作,将低压保安油泄掉,隔膜阀打开,泄掉高压保安油,快速遮断机组进汽。3.3.3危急遮断器滑阀危急遮断器滑阀是低压保安系统的枢纽,采用双通道,小滑阀顶部接受危急遮断器杠杆的控制,当危急遮断器动作时,杠杆将小滑阀压下,压力油进入A室,此时,大滑阀上部受到油压作用的面积大于下部B室受到油压作用的面积,大滑阀落下,泄掉低压保安油,使隔膜阀打开,卸掉高压保安油,快速关闭各主气阀,调节阀,遮断机组进汽。3.3.4危急遮断器试验阀危急遮断器试验阀的作用是移动危急遮断器杠杆;作喷油试验。主要有喷油电磁阀、试验电磁阀、集成块组成。工作原理如下:使试验电磁阀4YV带电,压力油经试验电磁阀进入杠杆,使杠杆向机头方向移动,脱开No2撞击子,然后到喷油电磁阀3AYV前,此时接近开关S2检测到杠杆位置信号3AYV带电,则压力油经3AYV进入No2喷油管,将NO2撞击子压出,危急遮断器电指示器发出撞击子压出信号,使3AYV,4YV郑东新区热电有限公司一期2×200MW机组工程汽轮机调节保安系统试验措施河南第一火电建设公司调试所-6-失电,则No2撞击子复位,杠杆回原位,No2撞击子喷油试验完成。同样,使试验电磁阀5YV带电,压力油经试验电磁阀进入杠杆,使杠杆向机头方向移动,脱开No1撞击子,然后到喷油电磁阀3BYV前,此时接近开关S1检测到杠杆位置信号3BYV带电,则压力油经3BYV进入No1喷油管,将No1撞击子压出,危急遮断器电指示器发出撞击子压出信号,使3BYV,5YV失电,则No1撞击子复位,杠杆回原位,No1撞击子喷油试验完成。3.3.5复位遮断阀组其作用是:(1)在掉闸状态下,根据运行人员指令使复位阀1YV带电动作,卸掉危急遮断器滑阀上腔室压力油,使危急遮断器滑阀挂闸。(2)当遮断时,遮断电磁阀2YV带电,泄掉危急遮断器滑阀下腔室压力油,使危急遮断器滑阀掉闸。复位遮断阀组主要由复位电磁阀,遮断电磁阀,集成块及压力开关组成。除挂闸信号外,复位电磁阀处于失电状态,此时复位电磁阀将1.96MPa压力油引入危急遮断器滑阀上腔室。当需要挂闸时,可使复位电磁阀带电,则复位电磁阀将危急遮断器滑阀上腔室接通排油,是滑阀在危急遮断器滑阀下腔室油压的作用下运动至上止点,此时再使复位电磁阀失电,危急遮断器滑阀上腔室油压重新恢复到1.96MPa,则工作挂闸完成。3.3.6蓄能器高压蓄能器为丁基橡胶皮囊式蓄能器共2组。通过集成块与系统相连,集成块包括隔离阀,排放阀以及压力表等,其中压力表指示的是油压而不是气压。它用来补充系统瞬间增加的耗油及减少系统油压脉动。预充氮压力为10MPa。低压蓄能器为皮囊式蓄能器共2组,每个低压蓄能器由两个丁基橡胶皮囊式蓄能器组成,要求安装在尽可能靠近蝶阀油动机的地方。用来在遮断状况发生时,吸收瞬间增加的排油,防止排油背压过高。集成块上的压力表仅仅指示油压,充氮压力0.2MPa。3.3.7高压遮断及超速限制模块主要由四个高压遮断电磁阀、二个超速限制电磁阀、二个试验压力开关、一个单向阀、二只节流孔及附件组成。正常情况下,四只遮断电磁阀全部带电使相应的泄荷阀关闭建立起高压安全油压。条件是隔膜阀阀关闭,此时各主汽阀油动机卸载阀处于关闭状态。当遮断汽机时,四只遮断电磁阀全部失电,泄掉高压安全油,同时通过单向阀泄掉超速限制安全油,快关各阀门。高压遮断模块的四只电磁阀为串并联结构,可实现在线试验功能。正常情况下,两只超速限制电磁阀全部失电,建立起超速限制油压,使各调节阀油郑东新区热电有限公司一期2×200MW机组工程汽轮机调节保安系统试验措施河南第一火电建设公司调试所-7-动机卸载阀处于关闭状态。当汽机转速达到103%额定转速或机组甩负荷时,两只电磁阀全部带电,泄掉OPC安全油,快关各调节阀门,限制汽机超速。3.3.8压力状态组件压力状态组件由三个压力开关,集成块及一些附件组成。用来监视低压保安油压,其作用是:当机组挂闸时,压力状态组件发出低压保安油压建立与否的信号给DEH,作为DEH判断挂闸是否成功的一条件;当机组遮断时,压力状态组件发出信号给DEH,DEH给高压遮断模块法出失电指令卸掉高压安全油,快关各阀门。以防止在隔膜阀拒动时不能有效折遮断阀门。3.3.9油动机3.3.9.1调节阀油动机本机组设有四个高压调节阀油动机,四个中压调节阀油动机,所有油动机均为单侧进油,保证在失去动力源的情况下油动机能够关闭。油动机由有油缸、位移传感器和控制器组成。在调节阀油动机的控制块上,装有伺服阀、卸载阀、遮断电磁阀和单向阀及测压接头等。3.3.9.2高中压主汽阀油动机设有两个高压主气阀油动机和两个中压主气阀油动机,所有油动机都采用两位开关控制方式控制阀门的关闭。由限位开关指示阀门的全开,全关和试验位置。3.3.10低润滑油压遮断器由7个压力开关组成。压力开关PSA1当油压降至0.049MPa报警压力开关PSA2当油压降至0.049MPa启动交流润滑油泵压力开关PSA3当油压降至0.0392MPa启动直流润滑油泵并报警压力开关PSA4当油压降至0.0294MPa切断盘车电机并报警压力开关PSA5、PSA6、PSA7当油压降至0.0294MPa三取二逻辑停机并报警3.3.11低凝汽器真空遮断器压力开关13PS当凝汽器真空升至0.0147MPa报警压力开关14PS、15PS、16PS当凝汽器真空升至0.0196MPa三取二逻辑停机并报警3.3.12抗燃油供油系统供油系统为调节保安系统各执行机构提供符合要求的高压抗燃油,同时保持液压油郑东新区热电有限公司一期2×200MW机组工程汽轮机调节保安系统试验措施河南第一火电建设公司调试所-8-的正常理化特性。它由集装式油箱、油泵、滤油器、安全阀、冷油器、油加热器、蓄能器、空气滤清器、液位计、温度开关、过滤器、油再生装置及必备的监视仪表组成。4调试内容及验评标准4.1调试内容4.1.1调节保安系统能完成机组复位、挂闸、驱动阀门及遮断机组的试验。4.1.2保安系统各部套特性调整与测试。4.1.3各阀门行程测量以及相关阀门LVDT整定。4.1.4汽门关闭时间测定。4.1.5阀门活动试验、喷油试验、阀门严密性试验、超速试验、甩负荷试验。4.1.6配合热工做