目录1前言.......................................................-1-1.1建筑电气简介..............................................-1-1.2工程概况..................................................-1-1.3设计原则..................................................-1-1.4设计内容..................................................-1-1.4.1电气照明系统设计........................................-2-1.4.2低压配电系统............................................-2-1.4.3防雷接地系统............................................-2-2电气照明系统设计.............................................-3-2.1总则......................................................-3-2.2办公楼电气设计需求分析....................................-3-2.3光源选择..................................................-3-2.4照明灯具选择..............................................-4-2.5设计结果..................................................-5-2.6照度计算.................................................-5-2.6.1本设计采用利用系数法计算灯具数量.......................-5-3低压配电系统设计.............................................-8-3.1负荷等级及供电要求.......................................-8-3.1.1负荷等级分类...........................................-8-3.2负荷计算.................................................-8-3.2.1计算照明负荷............................................-8-3.2.2断路器的选择...........................................-11-3.3设备选型结果............................................-13-3.4配电方式................................................-13-4防雷接地系统设计............................................-15-4.1建筑物的防雷简介.........................................-15-4.2本次工程分析.............................................-15-4.3第三类防雷建筑物的防雷措施...............................-16-4.4本建筑物防雷接地系统设计.................................-18-4.4.1屋顶防雷系统设计.......................................-18-4.4.2接地系统设计...........................................-18-5结论.....................................................-20-参考文献.....................................................-21-致谢.......................................................-22-附录.........................................................-23-摘要本次毕业设计为合肥市某办公楼的电气设计。在整个设计中,本人依据国家有关的设计规范和标准以及相关专业提供的设计资料,对这个工程的强电系统进行设计。设计的主要内容包括低压配电系统、一至三层电气照明系统及防雷接地系统,照明系统主要说明一般照明灯具及插座的选择,照度及照明计算负荷计算,应急照明的选择及安装等,用利用系数法进行计算,计算出各个房间合适的灯具数量。配电及布线方面,设计出各个供电回路相应的配电箱及走线方式,计算出各回路的计算负荷,最后选择好各个回路所需的线缆型号和保护器件型号,满足正常生活和安全的需要。对建筑防雷的设计,主要进行平面图设计。做完本毕业设计对建筑电气有了较为全面的认识。关键词:电气照明,配电系统,设备选型,防雷接地ABSTRACThegraduationdesignforabuildinginhefeitheelectricaldesign.Inthewholedesign,Iaccordingtorelevantstatedesignspecificationsandstandardsandrelevantprofessionaldesignmaterial,totheprojectinhighvoltagesystemdesign.Thedesignofthemaincontentincludinglowvoltagedistributionsystem,asecondfloorelectricallightingsystemandlightningproofgroundingsystem,lightingsystemthatmajorgenerallightinglampsandlanternsandsocketchoice,intensityofilluminationandlightingcalculationloadcalculation,emergencylightingselectionandinstallation,etc,withtheutilizationcoefficientmethodforthecalculation,eachroomrightoutthelampsandlanternsofquantity.Distributionandwiring,thepowersupplycircuitdesigneachcorrespondingdistributionboxandgolineway,calculatethecalculationoftheloopload,andfinallychoosegoodeachloopthecable,Finishthegraduationdesignofbuildingelectricalcanhaveacomprehensiveunderstandingofthearchitecturalelectricaldesign.KeyWords:Electricallighting;Distributionsystem;Equipmentselection;Lightningproofgrounding;某办公楼建筑电气设计1前言1.1建筑电气简介建筑电气是指电气工程技术在在建筑中的应用。随着建筑技术和电气科技的发展,尤其是随着信息技术的发展,如计算机技术、数字技术、显示技术、网络技术以及现代通信技术的发展,使建筑电气技术实现了飞跃性的发展,建筑科技含量越来越高。随着建筑电气新产品、新技术的不断涌现,建筑电气向着专业技术更加综合的方向发展。1.2工程概况该工程是六层办公建筑,一层是本楼大厅,二层和三层是办公区。本设计的目的是通过对该办公楼电气照明及防雷接地系统的设计,依据我国现行的相关设计规范,利用所学专业知识,理论联系实际,锻炼解决问题的能力,为自己以后的实际工作打下一定的基础。1.3设计原则本次设计是办公楼的电气设计,该楼以办公为主。设计坚持最大限度地满足用户合理需求的原则,设计需做到方案合理、运行可靠、简捷实用、便于操作、管理和维护,根据建筑物的设计要求,综合考虑国家现行的规范。在满足用户需求条件下,贯彻经济、适用的原则,减少各方面的投资,降低资源消耗,节约运行费用。建筑电气设计贯彻安全的原则,满足保障人身、设备和建筑物安全。使得建筑物达到满意适用、安全可靠、技术先进、经济合理、管理方便的要求。1.4设计内容本论文主要阐述了办公楼各系统电气设计的设计依据、原则和方法及设计选择的结论等。论文共包括3章内容。1.4.1电气照明系统设计本部分主要说明光源、灯具选择,照度计算,一般照明及应急照明等内容。本系统照度计算采用利用系数法进行计算,选择出各个房间合适的灯具数量,同时进行应急照明设计,本部分设计出图为各层照明平面图。1.4.2低压配电系统本部分主要说明负荷等级的划分及对应的供电要求,负荷计算以及配电方式等内容的相关原理、原则、方法等,并用需要系数法进行了负荷计算,确定各个系统照明负荷的容量、计算电流。从而选择出合适的配电线路线缆和保护设备如断路器,漏电保护装置等,以及各个供电回路相对应的配电箱。本部分设计出图为低压配电系统图。1.4.3防雷接地系统本部分主要说明防雷建筑物的分类及对应的防雷措施,对直击雷、雷电感应等的防护以及接地系统的方式及具体要求等内容,结合本建筑特点,做了防雷及接地系统设计,本部分设计出图为防雷平面图。2电气照明系统设计2.1总则电气照明设计的基本原则主要是安全、舒适、经济。为了最大限度的满足使用要求,同时符合相应国家设计规范,使照明设计尽量经济适用。就要合理选择照明方式、光源种类、灯泡功率、照明器数量。2.2办公楼电气设计需求分析本次设计的综合楼为综合办公楼,办公照明一般设计原则(1)办公楼的使用要求主要是人员的办公照明,照度太低会损害工作人员的视力,不合理的高照度则会浪费电力,照明设计要形成舒适的照明环境。办公室照明灯具宜采用荧光灯。插座按照办公需要合理布置。并设置空调插座。(2)在楼梯间、公共走廊等人流疏散通道应设置应急照明和疏散指示。(3)办公建筑照明标准值依据建筑照明设计标准(GB500034-2004),见下页表2.1表2.1房间照度要求表房间或场所参考平面及其高度照度标准值(lx)办公室、会议室0.75m水平面300门厅地面150候梯厅、卫生间地面75走廊地面50楼梯地面302.3光源选择照明电光源一般分为白炽灯、气体放电灯和其他电光源三大类,在绿色照明工程中,可根据具体情况,选择各种光源。(1)普通白炽灯特点:显色性好、开灯即亮、可连续调光、结构简单、价格低廉,但寿命短、光效低。用途:居室、客厅、大堂、客房、商店、餐厅、走道、会议室、庭院。运用方式:台灯、顶灯、壁灯、床头灯、走廊灯。(2)低气压放电灯①荧光灯荧光灯俗称日光灯。特点:光效高、寿命长、光色好。荧光灯有直管型、环型、紧凑型等,是应用范围十分广泛的节能照明光源。②低压钠灯特点:发光效率特高、寿命长、光通维持率高、透雾性强,但显色性差。用途:隧道、港口、码头、矿场等照明。(3)高强度气体放电灯高强度气体放电灯有:荧光高压汞灯、高压钠灯和金属卤化物灯。①荧光高压汞灯特点: