第1页共14页湖南正大轻科机械有限公司地址:长沙市雨花区环保东路158号(湖南环保科技产业园内)电话:0731-82883806传真:0731-82883812网址:金红叶纸业(沈阳)有限公司12万吨生活用纸项目造纸车间湿部吊顶、岗位送风系统使用说明书第2页共14页湖南正大轻科机械有限公司地址:长沙市雨花区环保东路158号(湖南环保科技产业园内)电话:0731-82883806传真:0731-82883812网址:目录一、概述···········································································1二、设备安装、使用与维护···················································31、气-水热回收装置··························································32、板式换热器装置···························································53、送风柜机····································································54、密闭定压膨胀罐···························································65、纸机湿部吊顶······························································7三、热水循环系统的控制与调试·············································7四、系统控制逻辑说明·······················································10五、系统操作步骤······························································11六、特别注意事项·····························································13第3页共14页湖南正大轻科机械有限公司地址:长沙市雨花区环保东路158号(湖南环保科技产业园内)电话:0731-82883806传真:0731-82883812网址:一、概述本系统用于纸机湿部、卷纸部的岗位送风及湿部吊顶送风。夏季时岗位送自然风,冬季时岗位送热风,纸机湿部吊顶全年送热风。本系统主要设备有:1、热水加热系统:气-水热回收及板式换热器等;2、热水循环系统:循环水泵、密闭定压膨胀罐、水管路等;3、岗位送风系统:送风柜机、送风风管;4、湿部吊顶及送风系统。送风热源为经换热器加热后的热水。本系统换热器设置有气-水热回收与汽-水板式换热器。冬季岗位送风热媒由气-水热回收及板式换热器提供热水,夏季时气-水热回收只回收少量的高温尾气,大部分高温尾气从旁通管路排入大气。仅在出现气-水热回收出口水温达不到设定值时才启用汽-水板式换热器为各送风柜机的换热器组提供热媒。纸机正常生产时,通常夏季停用板式换热器。经一级气-气热回收后的高温尾气通过二级气-水热回收装置的换热管内与循环热水间接传热后,使水温从700C升温到850C,再由板式换热器将循环水加热使水温从850C升高到950C.升温后的热水经管网系统泵送分配到各柜机内的铜管铝翘片加热器内,使新风温升符合吊顶送风的温度要求及冬季岗位送风温度要求。当气-水热回收装置的循环热水的出水温度超过设定温度或冬季送风岗位的风温较高时,系统将自动调节板式换热器的蒸汽用量或直至关闭板式换第4页共14页湖南正大轻科机械有限公司地址:长沙市雨花区环保东路158号(湖南环保科技产业园内)电话:0731-82883806传真:0731-82883812网址:热器系统,当关闭板式换热器加热系统后,水温或风温仍得不到有效控制时,必须手动调节减少进入气-水热回收换热段的高温尾气量,通过调节气-水热回收旁通排风管路的调节风阀,使过量部分(现场依具体实际确定)的高温尾气经旁通排风管排进大气中。当冬季岗位送风温度明显偏低时,需启用汽-水板式换热器将循环热水温度升至所需温度。循环水泵将热水输送到各送风柜机内的铜管换热器组加热新风,被加热后的新风由双侧进离心风机送达车间各受风点。纸机湿部吊顶送风温度设定为50℃,吊顶送风机组全年送热风,用于预热吊顶底面防止其表面产生凝露水滴。岗位送风温度按≥20℃设计,全年可通过开、停送风柜机组数来实现变风量运行,夏季全开,过渡季节及冬季,根据车间状况,酌情调整送风量、温度。热水循环管路上装配的各种仪表、阀门可对水量、水温进行可控可调,满足车间各受风区域工况要求。二、设备装置安装、使用与维护1、气-水热回收装置:汽-水热回收已普遍用于排风尾气余热的有效回收。换热段为不锈钢列管布置结构,工艺循环水走管程,高温尾气走壳程,流体之间为纯逆流传热。本回收装置设计循环水量230t/h,水温从50℃加热到70℃,可回收余热量为5348kw,相当于节约蒸汽(0.5MPa)9230kg/h。汽-水热回收由集气段、换热段、排气段等单元段组成。各段需在现场装配完成。第5页共14页湖南正大轻科机械有限公司地址:长沙市雨花区环保东路158号(湖南环保科技产业园内)电话:0731-82883806传真:0731-82883812网址:)、装配注意事项:集气段安装就位后,通过调节集气段底脚板与设备承重平台上预埋板之间的垫板厚度,使集气段法兰表面(换热段相接的面)水平度允差为≤3mm。集气段、换热段、排气段间法兰面采用4mm厚石棉橡胶板做密封材料,各段之间紧固件逐一紧固,确保法兰面密封可靠。各段组装成一体后,其高度方向垂直允差为≤4mm。调整合格后将集气段底脚板焊固于平台预埋板上。集气段底面排污口应与指定排污(水)管相联接或排污出口短管上带截止阀(用户自备)。确保设备运行时无高温尾气泄漏。换热段工艺循环水接口法兰处联接后须密封可靠,不得有任何渗漏。上部接口法兰为工艺水入口,下部接口法兰为工艺水出口,防止位置接错。2)、使用与维护考虑高温尾气温度随纸品产量变化而波动。因此换热段的出口水温也随纸品产量变化而波动。冬季时为确保各柜机出口送风温度的稳定,当受风点温度过高时,须及时调整进入换热段的尾气量。因此使用过程中应重点关注送风所需热功与尾气回收热功的平衡。纸机正常生产且冬季采暖送风的情况下,必须确保工艺循环水在管网内能顺畅流动。禁止将设置在各送风柜机的循环水管上的阀第6页共14页湖南正大轻科机械有限公司地址:长沙市雨花区环保东路158号(湖南环保科技产业园内)电话:0731-82883806传真:0731-82883812网址:门同时关闭,使工艺水在整个管网内停止流动,造成气-水热回收换热管内工艺水快速升温、汽化、管内压力增高。严重时将造成设备损坏或引发安全事故。夏季时,只有湿部吊顶1组仍需送热风,岗位无须送热风,3组岗位送风柜机已不再需要循环热水来加热新风,所需热负荷已非常少,只允许换热段回收少量尾气中的热能,绝大部分的高温尾气已不许进入换热段,必须从旁通管路上直接排入大气中。纸机停产检修时,必须检查换热管外壁的污渍情况,严重时须采用人工或化学清洗。2、板式换热器装置板式换热器是由许多片压制成人字形波纹形状的不锈钢板片经过真空钎焊而成。板式换热器热侧为饱和蒸汽循环区域,冷侧为被加热介质热水循环区域。本系统板式换热器使用蒸汽压力不得超过额定压力0.35MPa,以免发生本装置的可能损坏及安全事故。本系统板式换热器的安装、使用、维护请详见板式换热器用户手册循环水路系统供热水温为95℃,板式换热器是串联在汽-水热回收之后,若冬季设备检修或经过汽-水热回收后的循环水未达到95℃,则由板式换热器再加热至95℃,整个过程为自动控制恒温。3、送风柜机送风柜机主要由新风过滤段、铜管铝片换热器组、双侧进风离心风机、柜机骨架、柜机围护壁板等组成,出风口设有调节阀;机组采用模块化设计,铝型材骨架,外、内板采用彩色复塑钢板,防锈第7页共14页湖南正大轻科机械有限公司地址:长沙市雨花区环保东路158号(湖南环保科技产业园内)电话:0731-82883806传真:0731-82883812网址:耐腐蚀,美观大方,保温材料为聚本脂保温板;送风柜机设有检修门,人可方便进去查看检修,在人进去检修之前请务必停止风机马达的运转,以确保安全。本系统通过安装在送风口上的温度变送器,将送风温度输入DCS,并控制出水口处气动调节阀以调节加热器的循环水量,实现送风温度自动调节。柜机的进出水管上均装有温度表、压力表,可及时查看水路的温度及压力变化情况。当自动阀或柜机内水路部分出现故障时,可先关闭手动截止阀并排放柜机内热水进行设备检修。(1)、安装安装水平度≤0.1%,最大不超过8mm。放置于露天时,应考虑防雨措施。新风入口及出口不得承受300kgc以上(或2000mm长管道)的附加载荷送风出口处手动调节风阀水平安装,且调节灵活自如。柜机内风机安装按《风机安装使用说明书》进行。(2)、使用与维护新风过滤器应定期(半个月)清洗,以减少阻力。积尘严重时应适当增加清洗次数。4、密闭定压膨胀罐定压膨胀罐是热水循环系统自动补水装置并有效排除循环水中的气体。本装置通过补水管路上的压力变送经DCS控制自动补水泵(置于补水系统内),对热水循环系统实行自动补水。本装置第8页共14页湖南正大轻科机械有限公司地址:长沙市雨花区环保东路158号(湖南环保科技产业园内)电话:0731-82883806传真:0731-82883812网址:能根据热水循环系统要求设定并精确控制系统工作压力,并使罐体本身实现低水位安装,从而有效解决了安装位置、环境及气候条件等因素对定压膨胀系统影响,实现室内安装,便于冬季极限条件下系统防冻抗冻,供水、补水实现正常运行。密闭定压膨胀罐安装、操作、维护请详见《Digimat产品说明书》.5、纸机湿部吊顶纸机湿部吊顶送风温度设定为50℃,吊顶送风柜机全年送热风,用于预热吊顶底面防止其表面产生凝露水滴。吊顶上方设有检修门、钢结构行走平台,以方便人进去清扫维护。三、热水循环系统的控制与调试热水循环系统包括3台循环水泵,并联安装在主水管路上,两用一备,当1台水泵需要停机检修时,可开启备用水泵。在各段循环水管的最高位均装有排气阀,管道注满循环水后,在水路循环系统开启前,应手动开启排气阀使管道内的残留空气排尽。水泵前后都装有压力表,水泵正常工作时,出水口处压力表应显示在2-3kg/cm2之间,进水口处压力表应显示为负压,若进水口处显示偏低或偏高,应及时检查补水管路(DN32水管段)处有无堵塞或高位补水箱是否正常盛(蓄)水(高位水箱是循环水路系统的自动补水装置,补水管路应畅通,其进水应洁净无杂质,水箱内置自动补水浮球阀控制水箱蓄水量)。出水口处压力表指针显示偏高(大于4kg/cm2),水泵则处于过载状态,此时应及时检查循环系管路上各截第9页共14页湖南正大轻科机械有限公司地址:长沙市雨花区环保东路158号(湖南环保科技产业园内)电话:0731-82883806传真:0731-82883812网址:止阀是否开启量偏小,并特别检查压差旁通管路气动阀能否正常开启(此阀正常开启的压差应设定在约4kg/cm2左右,此参数依循环管路安装的具体情况确定);严禁水泵无水空载或常处于过载状态工作。若遇循环管路上压力表指针大幅偏摆跳动指示,应及时停机检查水路循环系统内是否有大量气体残留,并及时给系统补水以排除管道内气体。水