WinFTM-V6操作说明-简体

整理文档很辛苦,赏杯茶钱您下走!

免费阅读已结束,点击下载阅读编辑剩下 ...

阅读已结束,您可以下载文档离线阅读编辑

资源描述

(XULM-XYm.M9A(6.14))P.1荧光膜厚仪FischerscopeFischerscopeFischerscopeFischerscope使用手册机型:FischerscopeFischerscopeFischerscopeFischerscopeXULMXULMXULMXULM----XYmXYmXYmXYm(德国Fischer公司)(2006/6)(版本6.14)内容内容内容内容页页页页数数数数1111、仪器理想放置环境……………………………………………….……………………………………………….……………………………………………….……………………………………………….P.22222、测试台简介………………………………………………………………………………………………………………………………………………………………………………………………………………………………P.23333、电源开启………………………………………………………….………………………………………………………….………………………………………………………….………………………………………………………….P.44444、计算机开机……………………………………………………………………………………………………………………………………………………………….…………………….…………………….…………………….P.55555、基准测量………………………………………………………….………………………………………………………….………………………………………………………….………………………………………………………….P.56666、选择测试程式…………………………………………………………………………………………………………………………………………………………………………….…………….…………….…………….P.97777、归一化(Norm(Norm(Norm(Normalizealizealizealize))))……………………………………………………………………………………………………………………………………………………………………………………P.108888、测试步骤及样品放置方向……………………………………….……………………………………….……………………………………….……………………………………….P.129999、报表抬头的编辑、更改………………………………………….………………………………………….………………………………………….………………………………………….P.1410101010、快速打印步骤…………………………………………………….…………………………………………………….…………………………………………………….…………………………………………………….P.1511111111、删除读数…………………………………………………………………………………………………………………………………………………………………………………………………………………………………………P.1712121212、更改测试时间…………………………………………………………………………………………………………………………………………………………………………….…………….…………….…………….P.1813131313、测试单位公制((((µmµmµmµm))))或英制(u”)(u”)(u”)(u”)的选择……………………………………….………………….………………….………………….P.1914141414、光谱分析………………………………………………………….………………………………………………………….………………………………………………………….………………………………………………………….P.2015151515、样品图像放大倍数……………………………………………….……………………………………………….……………………………………………….……………………………………………….P.2116161616、中英文版软件切换……………………………………………….……………………………………………….……………………………………………….……………………………………………….P.2217171717、打印测试样品图像………………………………………………………………………………………………………………………………………………………………………………………………P.2318181818、产品程序备份与恢复…………………………………………………………………………………………………………………….…………………….…………………….…………………….P.2519191919、计算机死机的排除………………………………………………….………………………………………………….………………………………………………….………………………………………………….P.3020202020、计算机关机步骤………………………………………………………………….…………………………………………….…………………………………………….…………………………………………….P.3021212121、注意事项………………………………………………………….………………………………………………………….………………………………………………………….………………………………………………………….P.3222222222、辐射安全方面……………………………………………………………………………………………………………………………………………………………………………………………………………………P.3223232323、电器安全方面…………………………………………………….…………………………………………………….…………………………………………………….…………………………………………………….P.3324242424、仪器和附件的维修……………………………………………….……………………………………………….……………………………………………….……………………………………………….P.3325252525、常用元素符号、原子序、密度及合金的表示………………….………………….………………….………………….P.3326262626、列表符号意义…………………………………………………….…………………………………………………….…………………………………………………….…………………………………………………….P.3427272727、列表文字意义…………………………………………………….…………………………………………………….…………………………………………………….…………………………………………………….P.3528282828、测试范围………………………………………………………………………………………………………………………………………………………………………………………………………………………………….….….….P.3529292929、SSSStandardtandardtandardtandardDeviation(S)Deviation(S)Deviation(S)Deviation(S)标准偏差的计算公式及意义………………………………P.3730303030、C.O.C.O.C.O.C.O.VVVV.[%].[%].[%].[%]----变动率的计算公式…………………………………………………………………………………………………………………………………………P.3833331111、XULMXULMXULMXULM----XYmXYmXYmXYm图像无法显示的处理步骤……………………………………………………………………………………………………………………P.3932323232、底材修正步骤……………………………………………………………………………………………………………………………………………………………………………………………………………………P.4133333333、附录………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………P.42(XULM-XYm.M9A(6.14))P.21111理理理理、、、、仪器仪器仪器仪器想放置环境想放置环境想放置环境想放置环境A、使用工作环境:1)度温:10-25℃2)度湿:40-60%RH3)避免高温、潮湿及酸性腐蚀工作环境B量、耗电:5A(安培)2222、、、、测试台简介测试台简介测试台简介测试台简介可移动台面X-Y:250×280mmX-光管:微聚焦型(Micro-focus)测试孔径(Collimators):共4个No.1圆型、直径:0.10mm(4.0mils)No.2圆型、直径:0.20mm(8.0mils)No.3正方形:0.05×0.05mm(2.0×2.0mils)No.4长方形:0.03×0.20mm(1.0×8.0mils)测试台左方图示1.焦距调整2.高压开关3.电源开关4.视频输出5.RS-232系统连接头6.电源接头(XULM-XYm.M9A(6.14))P.3测试台右方图示1.X,Y工作台2.系统散热进气口过滤海绵测试台正面图示1.测量键2.停止键3.高压指示灯4.射线指示灯5.快门指示灯6.测试门关闭指示灯7.电源指示灯8.样品测试台(XULM-XYm.M9A(6.14))P.4更换电源保险丝::::保险丝位于电源座下,请用一字起子,打开保险丝座,换上同等安培数的保险丝即可。3333、、、、电源开启电源开启电源开启电源开启*开启计算机主机*开启仪器(含:照明与高压开关)*开启打印机((((注:开机后,请预热约33330000分钟后再使用))))(XULM-XYm.M9A(6.14))P.54444、、、、计算机开机计算机开机计算机开机计算机开机1)点击位于桌面上的FTM图示,移至[确定](OK)(OK)(OK)(OK)位置,按鼠标一下。5555、、、、基准测量基准测量基准测量基准测量1)把纯元素(Ag)放在测量台上,调整焦距使图像清晰。(XULM-XYm.M9A(6.14))P.62)移至菜单[一般](General)位置,按鼠标一下。往下8行,移至[量测基准((((RRRR))))]]]](ReferenceMeasurement)位置,再按鼠标一下。3)开始测试时,移至[量开始测基准(S)](SSSSttttartartartartRefeRefeRefeReferrrreeeence)nce)nce)nce)位置,再按鼠标一下。(XULM-XYm.M9A(6.14))P.7(注1111:[量开始测基准Ag]不按一下鼠标如动,请先到[一般](General))))行的第二[联线](Communicationon)按一下,再回来测量)。4)约等数秒后,显示如下画面。(XULM-XYm.M9A(6.14))P.85)画面显示[放入元素“Cu”],此时放入元素铜后按“确定“。(XULM-XYm.M9A(6.14))P.96)测量完成移至[确定](OK))))位置,再按鼠标一下即完成基准测量。说明量來:基准测是用确定本仪器是否正常,故每量天开机测前,必须预热后做此动作,如果无法通过此动作,即表示环境过度于潮湿,必须热机久些,或改变环境湿,切直到基准测量完成,才能继续下一步动作!记!6666、、、、选择测试程式选择测试程式选择测试程式选择测试程式1)移至命令按钮[选择](Select)Select)Select)Select)位置,再按鼠标一下。(XULM-XYm.M9A(6.14))P.102)选择测试程式a)例金﹕测试单层,则移至Au/NiAu/NiAu/NiAu

1 / 60
下载文档,编辑使用

©2015-2020 m.777doc.com 三七文档.

备案号:鲁ICP备2024069028号-1 客服联系 QQ:2149211541

×
保存成功