互联王深圳国际云计算服务中心简介HLWidcShenzhenInternationalCloudComputingServiceCenterSummary互联王SECTION*园区环境ParkenvironmentSOUIDCSHENZHENDATACENTERGRAPHIC深圳数据中心图园区地址:深圳市南山区科技园科发路3号长城科技大厦;邮编:518057Parkaddress:GreatWallTechologyBuilding,KefaRoadNo.3,SciencePark,NanshanDistrict,Shenzhen;Zipcode:518057地理优势:从到达滨海大道、北环大道5分钟车程,到达前海开发区、深圳中心商业区20分钟,到达宝安国际机场30分钟。未来到达香港国际机场、澳门30分钟。GeographicalAdvantages:Itis5minutes’drivefromBinhaiAvenueandBeihuanAvenue,20minutes’drivefromQianhaidevelopmentZoneandShenzhencentralbusinessdistrict,30minutes’drivefromBaoanInternationalAirport.Infuture,ittakes30minutestodrivetoHKInternationalAirportandMacao.地理位置Location外部资源示意图机房楼IDCbuilding办公楼Officebuilding访客停车场Visitorparkinglot深南大道ShennanAvenue科苑路keyuanRoad柴发dieselgeneratingsetsExternalresourcesmap建设等级Constructionlevel:Tier4园区总占地面积Totalareaofthepark:20000㎡机房楼IDCbuilding:2F/工业建筑,分两期实施Theindustrialconstructionintwophasestoimplement框架结构,抗震乙级设防烈度7度Framestructure,SeismicB,Theseismicfortificationintensityof7degrees机柜数量CabinetQty:3875Racks供电密度Powerdensity:13A~20A/rack园区总体设计参数ParameterofthezoneoveralldesignARCHITECTURALSTRUCTUREOFDATACENTER数据中心建筑结构数据中心建筑结构工业级厂房结构,数据中心总面积20000㎡Industrialworkshopstructurewithtotalareaof20000㎡抗震防裂度7度,建筑安全等级1级,框架抗震等级为8级Itisdesignedtowithstandanearthquakeof7.1magnitude,buildingsafetylevel1,andframeworkofseismiclevel82部专用3吨货梯,1部专用2吨升降机two3-tonladdersspeciallyforgoods,one2-tonspecialelevatorSECTION*机房楼内部结构TheinternalstructureofIDCbuilding面积area/m²承重load-bearing(kg/m²)层高floorheight(m)功能模块Functionmodule可用机柜Availablecabinets机柜容量Cabinetcapacity(KW)UPS方式UPSmethods机柜送风方式Cabinetairsupplymode3楼3rdfloor110001200KG/㎡7m每一个机房模块均拥有独立变压器、低压配电单元、UPS不间断电源系统、安防控制单元,级联接地,分区气体灭火系统,机房模块设计完全遵循国家GB50174-2008电子信息机房设计标准A类机房最高标准。Eachmoduleisequippedwithindependenttransformer,lowvoltagepowerdistributionunits,UPSuninterruptiblepowersupplysystems,securitycontrolunit,levelconnection,andgasfireextinguishingsystempartition.ThemoduledesigncompletelyfollowthenationalGB50174-2008electronicIDCdesignstandardwhichbelongstocategoryA,thehigheststandard.25252.86kW~4.4kW2N冗余配置2NRedundantconfiguration下送上回sentunderthelast2楼2ndfloor3000800KG/㎡4.2m4752.86kW~4.4kW2N冗余配置下送上回1楼1stfloor60001200KG/㎡4.8m8922.86kW~4.4kW2N冗余配置下送上回FloorplanedistributionandProductspecifications楼层平面分布与产品规格Planelayoutof1F,1F/平面布置图大厅演示厅会议室NOC总控中心MOD/1-1MOD/1-5MOD/1-2MOD/1-3MOD/1-4MOD/1-6MOD/1-8MOD/1-7货梯卸货平台PlanelayoutofInterlayer1F/夹层平面布置图大厅演示厅会议室NOC总控中心MOD/1-1MOD/1-5MOD/1-2MOD/1-3MOD/1-4MOD/1-6MOD/1-8MOD/1-7货梯卸货平台Planelayoutof2F,2F/平面布置图大厅演示厅会议室NOC总控中心MOD/1-1MOD/1-5MOD/1-2MOD/1-3MOD/1-4MOD/1-6MOD/1-8MOD/1-7货梯卸货平台ExhibitionHall1F/展厅Thestairs&corridorin1F,1F/楼梯间&走廊REALFIGUREOFMODULE模块内实景图SECTION*机房基础设施Infrastructure总控中心Master-controlcentre消防系统分控中心Firefightingsystemcontrolcenter配电系统分控中心Powersystemcontrolcenter冷水系统分控中心Coldwatersystemcontrolcenter网络系统分控中心Networksystemcontrolcenter环境安防控制中心Environmentalsecuritycontrolcenter智能控制分总结合,运维便利,安全无忧Intelligentcontrol,Masterandbranchcombination,Convenienceforoperationandmaintenance,andSecure市电:四回路10KV高压输入,来自不同变电站大冲站花卉站翡翠站桃园站。总供电量30000KVA标准供电密度13A/rack-20A/rack.Alternatingcurrent:4loop10KVhighvoltageinputfromdifferentsubstations.Thetotalpowersupply30000KVA,Standardpowerdensityof13A/rack-20A/rack后备油机:10台2000KW发电机(进口Caterpillar),10KV高压柴油发电机系统分为两组,每组5台,2N+1配置,每台1800KVA的应急电力装机容量,本地8小时油量储备,和深圳市中石油,中石化销售公司签署的供油协议,满足无间断的应急电力输出保障Backupgenerators:The102000KWgenerators(Caterpillar),10KVhighpressuredieselgeneratorsystemaredividedintotwogroups,5ineachgroup,arrangedby2N+1.Eachofthemhasemergencypowerinstalledcapacityof1800KVA,with8hoursoilreserves.WehavesignedOilSupplementAgreementwithCNPCandSinopecforuninterruptedemergencypoweroutputguarantee.设计单个机柜容量为2.86kW~4.4kW,如用户有特殊需求,还可根据用户需求进行定制。每机柜均具有独立的机架接电,两路PDU接入,实现机柜供电的冗余。Thecapacityofasinglerackisdesignedtobe2.86kW~4.4kW,anditcanbecustomizedaccordingtocustomersrequirements.EachcabinethasindependentrackconnectingtoelectricitywithtwoPDUaccess,whichbringsredundantpowersupply.UPS供电:400KVA/unit,2N冗余配置,满载后备时间15分钟UPSpowersupply:400KVA/unit,2NRedundantconfiguration,15minutesfullloadbackup.InfrastructureIntroduction-Powersupplysystem基础设施介绍—电力系统InfrastructureIntroduction-Airconditioningsystem基础设施介绍—空调系统园区市政两路进水给数据中心制冷系统,独具的机柜冷通道隔离部署,保障最高冷量效率。Toguaranteethehighestcoolingefficiency,itisequippedwithParkMunicipaltwowaterinlettodatacenterrefrigerationsystem,uniquedeploymentofcabinetcoolingchannelisolation.所有的空调制冷设备,均安装在机房模块外独立设备区内,与客户机柜区域完全物理隔离,为客户机柜提供更加私密性和最大保护功能。Alltheairconditioningandrefrigerationequipmentswereinstalledoutsidethemodulesintheindependentarea,physicallyisolatedcustomercabinets,inwhichprovidemoreprivacyandmaximumprotectionfunctionforcustomercabinets.冷水机组Waterchillingunit:TRANE1200冷吨/unit,3(主main)+1(备backup)冗余配置Redundantconfiguration:YOUK800冷吨/unit,3(主main)+1(备backup)冗余配置Redundantconfiguration精密空调Precisionairconditioning:EMERSONN+1冗余配置–确保机房内温度稳定在Ensuretemperaturestablein23±1℃、相对湿度Relativehumidity40—50%立体安防智慧管理Three-dimensionalwisdomsecuritymanagement:监控中心提供24x7x365全年无间断中央监测服务Themonitoringcenterprovides24x7x365annualuninterrupt