S9—M三相油浸式全密封电力变压器技术数据表产品型号额定容量(kVA)额定电压联接组空载损耗(W)负载损耗(W)空载电流(%)阻抗电压(%)重量(kg)轨距外形尺寸(长×宽×高)高压(kV)分接范围低压(kV)器身重(kg)油重(kg)总重(kg)S11-M.R-30/103066.310±5%0.4Y,yn0906000.64.016585340400900×520×900S11-M.R-50/10501208700.622095420950×510×980S11-M.R-63/106314010400.572601054801010×580×1000S11-M.R-80/108017512500.543001105201040×600×1020S11-M.R-100/1010020015000.483501255801150×620×1100S11-M.R-125/1012523518000.454001356805501150×620×1100S11-M.R-160/1016028022000.424801657901200×640×1180S11-M.R-200/1020033526000.395601859301240×660×1180S11-M.-250/1025039030500.3668021011501320×700×1200S11-M.R-315/1031546536500.3380024012806601400×780×1200S11-M.R-400/1040056043000.398029015601460×820×1380S11-M.R-500/1050067051500.3120034018201520×860×142010KV级S7、S9、S11系列电力变压器技术数据容量空载损耗(W)负载损耗(W)空载电流%阻抗电压%KVAS7S9S11S7S9S11S7S9、S11S7、S9、S1130150130908006006002.82.145019017012011508708702.62.0802702501751650125012502.41.81003202902052000150015002.31.61253703402402450180018002.21.51604604002802850220022002.11.42005404803353400260026002.11.32506405603904000305030502.01.23157606704704800365036502.01.1S9与S7相比:空载损耗平均下降10.25%,年运行成本平均下降18.91%。S11与S9相比:空载损耗平均下降30%,年运行成本平均下降11.68%。S9-30~1600/10电力变压器规格与主要技术数据额定容量KVA联接组别电压(KV)损耗(W)阻抗电压(%)空载电流(%)重量(kg)外形尺寸(长*宽*高)高压低压空载负载器身重油重总重30Yyno100.413060042.1140702801061*729*113350101708702.0205803751105*744*1183801024012501.82801004901125*755*12831001029015001.63251105601130*815*13181601040022001.44501407601230*840*14232001048026001.35251658751357*855*14482501056030501.262519010401408*914*15083151067036501.174522012251423*1051*15334001080043001.090527514651540*1116*16085001096051001.0105030517151595*1280*166863010120062004.50.9128039521101595*1280*166880010140075000.81510455257519551325*18821000101700103000.7167552528601975*1335*19571250101950120000.6195558533302000*1340*20121600102400145000.6239067039702130*1375*2234S11-M系列全密封油浸式配电变压器是在新型S9系列产品结构设计的基础上进行开发的科技新产品。设计的主导思想是满足产品的可靠性,提高产品的性能,根据新S9产品的实际情况,重新调整了一些损耗系数和结构,使损耗设计值更符合实测值,同时进行了优化设计,合理确定铜铁比例,使材料成本最低,结构合理。S11-30~1600/6-10电力变压器规格与主要技术数据额定容量电压KV损耗W阻抗电压%空载电流%联接组别重量kg外形尺寸(长*宽*高)轨距(mm)高压低压空载负载器身重油重总重1066.3100.44Y,yno20301006002.814859280980*560*1030400*400501308702.5215743761040*580*1080400*4006315010402.4249814251060*752*1100400*4008018012502.2308925071110*762*1140400*40010020015002.13491035881092*772*1170550*55012524018002.04171156821155*782*1214550*55016027022001.94951318071240*792*1254550*55020033026001.85811609521400*812*1350550*55025040030501.870017811221470*818*1455550*55031548036501.880420412811448*938*1500550*55040057043001.597022515081488*848*1550550*55050068051501.4114325417601610*868*1620600*60063081062004.51.3128830620251748*1042*1635600*60080098075001.0171046327812050*1125*2170820*66010001150103000.7174853330032030*1125*2220820*66012501360120000.6205361530522220*1294*2025820*66016001640145000.6264074043272600*1326*2213820*660变压器的连接组别介绍变压器三相绕组有星型联结、三角形联结与曲折联结等三种联结法。在绕组联结中常用大写字母A、B、C表示高压绕组首端,用X、Y、Z表示其末端;用小写字母a、b、c表示低压绕组首端,x、y、z表示其末端,用o表示中性点。新标准对星型、三角形和曲折形联结,对高压绕组分别用符号Y、D、Z表示;对中压和低压绕组分别用y、d、z表示。有中性点引出时分别用YN、ZN和yn、zn表示。自藕变压器有公共部分的两绕组中额定电压低的一个用符号a表示。变压器按高压、中压和低压绕组联结的顺序组合起来就是绕组的联结组。例如:高压为Y,低压为yn联结,那么绕组联结组为Yyn。加上时钟法表示高低压侧相量关系就是联结组别。常用的三种联结组别有不同的特征:1Y联结:绕组电流等于线电流,绕组电压等于线电压的1/√3,且可以做成分级绝缘;另外,中性点引出接地,也可以用来实现四线制供电。这种联结的主要缺点是没有三次谐波电流的循环回路。2D联结:D联结的特征与Y联结的特征正好相反。3Z联结:Z联结具有Y联结的优点,匝数要比Y形联结多15.5%。成本较大。据GB/T6451-1999《三相油浸式电力变压器技术参数和要求》和GB/T10228-1997《干式电力变压器技术参数和要求》规定,配电变压器可采用Dyn11联结。而我国新颁布的国家规范《民用建筑电气设计规范》、《工业与民用供配电系统设计规范》、《10KV及以下变电所设计规范》等推荐采用Dyn11联结变压器用作配电变压器。现在国际上大多数国家的配电变压器均采用Dyn11联结,主要是由于采用Dyn11联结较之采用Yyn0联结有优点:3.1D联结对抑制高次谐波的恶劣影响有很大作用3.1.1在D联结绕组中的三次谐波环流能够在变压器中产生三次谐波磁动势,它与低压绕组的三次谐波磁动势平衡抵消;3.1.2高压相绕组的三次谐波电动势在D联结回路中环流,三次谐波电流可在D联结的一次绕组内形成环流,使之不致注入公共的高压电网中去。3.2Dyn11联结变压器的零序阻抗比Yyn0联结变压器小得多,有利于低压单相接地短路故障的切除。3.3Dyn11联结变压器允许中性线电流达到相电流的75%以上。因此,其承受不平衡负载的能力远比Yyn0联结变压器大。3.4当高压侧一相熔丝熔断时,Dyn11联结变压器另二相负载仍可运行,而Yyn0却不行。因此,在变压器联结组别选择中,选择Dyn11联结变压器很有必要。由于Yyn0联结变压器高压绕组的绝缘强度要求较之Dyn11联结变压器稍低,所以,不宜将Yyn0联结变压器改为Dyn11联结。

1 / 7
下载文档,编辑使用

©2015-2020 m.777doc.com 三七文档.

备案号:鲁ICP备2024069028号-1 客服联系 QQ:2149211541

×
保存成功