目录机房设计方案······························································································一、简介······································································································二、用户需求······························································································三、机房网络设计原则··············································································四、建设目标:··························································································五、网线布线设计······················································································六、机房接地设计······················································································七、网络设计方案······················································································八、机房电器系统设计··············································································九、机房消防系统设计··············································································十、机房建设及综合布线系统预算单······················································机房设计方案一、简介随着企业事业的飞速发展,企业机房建设已经成为一个企业势力的重要组成部分。随着科学技术的不断发展,网络互连技术迅猛发展。以快速稳定的网络来进行现代化科研及办公,把计算机网络技术应用至教育、科研、管理信息等领域,并实现与Internet网的汇接,实现计算机网络办公自动化,计算机管理现代化,以此提高现有人员的技术素质、工作效率和管理水平,使之为生产科研发挥更大作用。不论是企业、事业单位还是个人用户对网络都提出了更高的要求,网络信息、数据、资料的安全、稳定的交流和传输,是现代化计算机网络技术的主流。特别是基于Internet模式的信息系统的结构,改变了传统模式下的管理系统的结构,使系统使用更加方便、快捷。建立基于Internet/Intranet的计算机网络不仅能够为财务管理和电子邮件、电子资料、文件传输、、分布式广域数据库的服务、国际互联网的交流提供便利,更是现代化办公和管理不可缺少的有利工具。二、用户需求根据贵公司其实际情况和需要,将作以下描述:计算机:188台计算机、交换机等设备.预留61个信息点网络组建:实现249个信息点的信息流通。三、机房网络设计原则根据企业需求及网络发展,我们在设计建设整个网络的过程中,遵循如下原则:●先进性和兼容性原则网络建设应适应目标管理自身发展的特点及网络通信技术更新换代,主机系统选择、网络结构设计、网络管理和连接方式具有一定的先进性。●标准性原则网络总体建设遵循国际统一标准、采用业界流行的通用通讯协议和接口,要为系统能顺利接入国际互联网提供一个良好的环境。●开放性建成多协议、多网络操作系统网络平台,真正实现开放式的网络体系结构。●可靠性原则网络是系统集成的关键,要求系统中的任何设备的故障都不会影响整个系统连续、可靠的运行。首先要考虑设备的稳定性、可靠性、使其具有必要的冗余容错能力,特别是主干通信线路和核心设备,如:中心交换机,可采用电源冗余备份系统,提高可靠性。●安全性实现网络的合理配置,利用授权及软件防火墙技术,能阻止非法用户访问网络资源,保证数据传输、存储的安全。●可管理性对整个网络系统提供管理软件,实现网络的动态管理,流量控制及故障诊断。●经济实用性原则整套应用系统应能方便用户的使用和管理,以实际工作的业务模式为基础,实现业务处理的计算机化;并能做到用户界面的友好统一,应用平台的简单化和标准化。四、建设目标:整个网络建成之后,将达到如下目标:A、网络运行稳定、速度快B、整个网络完成后具有良好的扩展性,为以后升级余留了空间。C、只要添加外接设备,就很容易实现所有电脑接入INTERNET,并能与更多的教育站进行互联,实现网上资源共享。D、网络管理容易,可操作性强,实用性强。五、网线布线设计在对双绞线进行安装时,应该注意下列事项:★不能在线缆上足以施线缆表面和导线上留下永久痕迹的力量★施中过程中不能对线缆使用热吹风式气焊枪等加热方法★在线缆端接时应该使双绞线保持其端接模块接通★线缆拐弯时应该保证足够大的转弯半径施工参数:★最小弯曲半径≥8×线缆半径★天花板内最大暴露双绞线长度为≤2cm,(机柜处除外)★最大分绞长度不超过2cm★线上不得负重载重物★如果线缆必须穿越电源线,应该垂直穿越★最大拉力,不管是多少对线,不得超过400N线槽:★在安装线槽时,首先应该计算线槽中将要放的线缆的数量与重量,以免线槽的支撑点负载超过建筑物结构上所容许的负载。★如果线槽是管状的,不能开盖,安装时,在每一个拐弯的地方要求有线盒,另外,在安装时应先安装引线,以方便穿线。★所有需固定的线槽都要加固定件,不能有松动或脱落。★线槽中的线缆应该固定在线槽上,在垂直线槽中,要求每610mm有一个线捆把线缆固定在线槽上。六、机房接地设计根据《电子计算机机房设计规范》GB50174-93及CECS72-97综合布线工程规范,机房所在楼宇应有联合接地体,在主配线间应有3欧以下的接地端子。七、网络设计方案1网络体系结构在整个网络建设中,网络采用快速以太网技术,保证数据的传输的带宽保持在100M上。运用超五类双绞线连接网络主干,采用混合式10/100/1000M快速以太网连接到桌面。此种结构具有灵活的扩充性,可满足用户在以后网络增长的需要及方便的接入;易于维护,在不影响整个网络正常运行的情况下,自由插拔与更换;保证网络主干数据的快速传输,减少网络数据的传输“瓶颈”,提高网络性能。整个网络以服务器做为该企业网的网络数据中心,运用双绞线接连各台计算机。1000M双绞线主干连接各个工作站。2、网络总体设计本方案中,将以服务器为中心,其它各工作站作为网络主干用户。桌面采用1000M交换速率传输。服务器的主要任务是提供Internet信息服务、数据服务和文件服务八、机房电器系统设计充分考虑所设计的机房系统的工作性质和任务,以电源供配电的质量、电气装置工作的可靠性,安全性和技术上的先进性、人员工作环境的舒适性为设计原则。机房内用电设备供电电源均为三相五线制及单相三线制,采用双回路供电;用电设备作接地保护,并入土建大楼配电系统;机房用电设备、配电线路装置过流过载两段保护,同时配电系统各级之间有选择性地配合,配电以放射式向用电设备供电;机房配电系统所用电线为珠江电缆阻燃聚氯乙烯绝缘导线,敷设喷塑桥架、镀锌铁管及金属软管。机房的设备供电和空调照明供电分为两个独立回路,其中设备供电由UPS提供并按设备总用电量的1.3倍进行预留,而空调照明用电由市电提供并按空调设备的要求供配。机房内照明装置宜采用机房专用无眩光灯盘,照明亮度大于300LUX,事故照明亮度应大于60LUX。机房内的配电系统考虑了与应急照明系统的自动切换。该机房电源进线正常时由市电供电,市电故障时由UPS供电,进线直接引入机房专用配电柜总输入开关。机房设计了一个市电配电箱,对机房的市电进行配电,配电箱为机房专用标准配电箱,配备低压开关。柜内配有市电备用回路,安装防雷保护器。机房设计了一个UPS配电箱,对机房的UPS电进行配电,配电箱为机房专用标准配电箱。箱内配有UPS电源备用回路。机房所有插座均采用普通电源插座和弹起式铜插座,普通电源插座安装在墙壁上,弹起式电源插座安装在防静电地板上,美观大方。二、电气设计依据●国标GB2887-89《计算站场地技术条件》●国标GB50174-93《电子计算机房设计规范》●国标GB9361-88《计算站场地安全要求》●国标GBJ52-82《工业与民用供电系统设计规范》●国标GBJ54-83《低压配电装置及线路设计规范》●国标GBJ232-83《电气装置安装工程及验收规范》三、电源部分:1、负荷及电源进线机房负荷计算:计算机设备用电空调、新风设备用电照明及辅助用电机房扩展备份用电2、计算机机房总用电量电源的容量:应保障计算机设备、空调、新风设备的用电。市电与市电间、市电与UPS的切换应在配电间完成。进线:由大楼中心配电室经竖井引入四路五芯VV-ZR系列(难燃型)电缆经金属线槽暗敷引入机房配电间:两路双回路低压电源供电。3、配电设备:在机房配电间设置一台动力配电柜,一台照明配电箱:(1)动力配电柜负责空调、照明、机房内设电源插座及机房扩展备份用电控制。(2)照明配电箱负责机房内所有区域照明.4、配电柜结构:配电柜进线采用上进下出方式。具有如下特点:操作,维护互不干扰;端子接线保障设备安全;屏面模拟板使操作简易掌握,同时防止误操作。5、电气元件选择:空气开关选用进口产品;其它元器件均选用合资产品(继电器,指示灯,端按钮等)6、弱电部分弱电布线系统全部采用桥架布线,每台机柜布双网线,7、桥架选择除照明、辅助插座采用金属管配线外,其余所有线缆均采用桥架布线。8、配电线缆部分配电线缆采用阻燃型电缆或交联阻燃电缆。四、照明系统1、照明方式工作区域采用3×20W格栅灯具照明,照度在300勒克斯-600勒克斯选择。2、照明控制灯具照明控制选用开关箱,跷板开关控制。灯具控制开关选用俊朗产品。3、辅助用电机房区域内墙面辅助用电插座选用俊朗产品.4、应急照明灯应用应急照明灯,照度为60LUX。五、配电系统设计市电配电柜部分:该部分采用机房专用配电箱来完成,它接到总配电室送过来的市电电源,通过总电源开关,输出到分支回路中,我们为该部分设计了18条回路:照明回路6条,中央空调回路1条,新风机回路1条,其它辅助插座回路5条,备用回路3条。UPS电源部分:该部分采用机房专用配电箱来完成,它接到UPS送过来的单路电源,通过160A总电源开关,输出到分支回路中,我们为该部分设计了十五条回路:服务器回路2条,监控报警回路1条,交换机回路2条,工作站回路2条,消防回路1条,备用回路6条,精密空调回路1条。九、机房消防系统设计机房区域消防系统分为消防自动报警系统和消防灭火系统。由于机房内部火灾主要为电气火灾,而机房的吊顶上、地板下有大量的配电线路,因此需设置吊顶上、吊顶下、地板下三层报警;机房内大量的计算机及外联设备严格要求使用气体来灭火。一、设计内容信范围此工程为机房七氟丙烷气体消防工程本设计共对主机房、集线室、配电间、地板下共四个保护区进行七氟丙烷气体自动灭火系统有管网设计。(其中将地板下单独设为一个区)二、设计依据1、国际标准草案《气体灭火系统——物理性能和系统设计》ISO/CD/14520-92、《七氟丙烷(HFC-227ea)洁净气体灭火系统设计规范》DBJ15-23-19993、《七氟丙烷灭火系统施工及验收规范》Q/QS03-20014、甲方提供的应保护区域的建筑平面布置图。三、基本设计参数1、系统储存压力:4.2Mpa(70L、90L)2、喷头入口