QSYJS0125-2015天然气管道站场雷电防护技术要求

整理文档很辛苦,赏杯茶钱您下走!

免费阅读已结束,点击下载阅读编辑剩下 ...

阅读已结束,您可以下载文档离线阅读编辑

资源描述

天然气管道站场雷电防护技术要求Technicalrequirementsoflightningprotectionfornaturalgaspipelinestation2015-03-20发布2015-03-20实施中石油北京天然气管道有限公司发布中石油北京天然气管道有限公司企业标准Q/SYQ/SYJS0125—2015代替Q/SYJS0125—2012Q/SYJS0125—2015I目次前言...............................................................................III 1范围..............................................................................1 2规范性引用文件....................................................................1 3术语、定义和缩略语................................................................13.1术语和定义....................................................................13.2缩略语........................................................................74一般原则..........................................................................7 5直击雷防护........................................................................8 6接地网............................................................................8 6.1地网结构......................................................................8 6.2接地体........................................................................9 6.3接地引入线...................................................................10 6.4地网施工验收要求.............................................................10 7户外电缆及端口的防护.............................................................10 7.1电缆敷设及选型要求...........................................................10 7.2电缆安装要求.................................................................12 7.3信号SPD使用与安装要求.......................................................15 7.4信号SPD的选型要求...........................................................16 8机房内等电位连接.................................................................17 8.1等电位连接结构...............................................................17 8.2接地线.......................................................................19 8.3室内信号线缆布放要求.........................................................20 8.4控制机柜内接地及布线要求.....................................................21 9低压配电系统的防雷...............................................................22 9.1进站电缆防护要求.............................................................22 9.2电源系统雷电过电压保护要求...................................................22 9.3电源电涌保护器使用要求.......................................................23 9.4电源电涌保护器安装要求.......................................................24 10其他设备的防雷和部分防静电装置..................................................25 10.1阴极保护系统的防雷..........................................................25 10.2工业监视系统的防雷..........................................................26 10.3传输、网络接口的防雷........................................................27 10.4绝缘接头的防雷..............................................................27Q/SYJS0125—2015II10.5部分防静电装置................................................................2711防雷接地装置维护要求.............................................................29 11.1一般原则.....................................................................29 11.2防雷检测流程.................................................................30 附录A(规范性附录)站场雷电防护等级分级.............................................32 附录B(资料性附录)防雷接地装置工程验收记录表........................................34 附录C(资料性附录)陕京管道沿线市、县年平均雷暴日数统计表............................36附录D(规范性附录)《站场明敷接地扁钢安装技术要求》..................................38附录E(规范性附录)《站场明敷接地导线安装技术要求》....................................45附录F(规范性附录)《静电释放柱安装技术要求》..........................................47附录G(规范性附录)《排污池清污罐车专用静电接地置安装技术要求》........................49附录H(规范性附录)《五孔以下法兰跨接线安装技术要求》...................................59Q/SYJS0125—2015III前言本标准根据GB/T1.1—2009给出的规则起草。本标准替代了Q/SYJS0125—2012《天然气管道站场雷电防护技术要求》。与Q/SYJS0125—2012《天然气管道站场雷电防护技术要求》相比,主要技术变化如下:—调整了对于五孔以下法兰跨接的要求。—增加了附录D《站场明敷接地扁钢安装技术要求》、附录E《站场明敷接地导线安装技术要求》、附录F《静电释放柱安装技术要求》、附录G《排污池清污罐车专用静电接地装置安装技术要求》、附录H《五孔以下法兰跨接线安装技术要求》。—修订了附录C《陕京管道沿线市、县年平均雷暴日数统计表》。本标准由中石油北京天然气管道有限公司标准化技术委员会电信控专标委提出并归口。本标准起草单位:中石油北京天然气管道有限公司、中讯邮电咨询设计院有限公司本标准主要起草人:刘吉克李国海陈强傅建湘董秀娟李勇葛艾天王健赵文明闻波、胡贞Q/SYJS0125—20151天然气管道站场雷电防护技术要求1范围本标准规定了北京天然气管道公司所辖天然气管道站场雷电防护的一般原则,并给出了综合防护指南。本标准适用于北京天然气管道公司所辖天然气管道中各类新建站场的雷电防护工程设计、施工及维护。站场改、扩建及现有站场的防雷改造工程参照本标准执行。2规范性引用文件下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅所注日期的版本适用于本文件。凡是不注日期的引用文件,其昀新版本(包括所有的修改单)适用于本文件。GB4943-2001信息技术设备的安全GB15599-2009石油与石油设施雷电安全规范GB/T19856.1-2005雷电防护通信线路第1部分光缆GB/T19856.2-2005雷电防护通信线路第2部分金属导线GB50057-2010建筑物防雷设计规范GB50058-92爆炸和火灾危险环境电力装置设计规范GB50169接地装置施工及验收规范GB50343-2004建筑物电子信息系统防雷技术规范GB50601建筑物防雷工程施工与质量验收规范GB50650-2011石油化工装置防雷设计规范GB/T50689-2011通信局(站)防雷与接地工程设计规范DL/T381-2010电子设备防雷技术导则DL/T620-1997交流电气装置的过电压保护和绝缘配合Q/SY1268输油气站场防雷设计导则SH/T3081-2003石油化工仪表接地设计规范YD/T1235.1通信局(站)低压配电系统电涌保护器技术要求YD/T1542信号网络电涌保护器(SPD)技术要求和测试方法3术语、定义和缩略语3.1术语和定义下列术语和定义适用于本文件。3.1.1雷暴日ThunderstormDay一天中可听到一次以上的雷声则称为一个雷暴日。Q/SYJS0125—201523.1.2雷电活动区KeraunicZones根据年平均雷暴日的多少,雷电活动区分为少雷区、多雷区、高雷区和强雷区;少雷区为一年平均雷暴日不超过20天的地区;多雷区为一年平均雷暴日在21~40天的地区;高雷区为一年平均雷暴日在41~60天的地区;强雷区为一年平均雷暴日超过60天的地区。3.1.3雷击LightningStroke雷云对大地及地面物体的放电现象。3.1.4直击雷DirectLightningFlash直接击在建筑物或防雷装置上的闪电。3.1.5雷电过电压LightningOvervoltage因特定的雷电放电,在系统中一定位置上出现的瞬态过电压。3.1.6雷电电

1 / 69
下载文档,编辑使用

©2015-2020 m.777doc.com 三七文档.

备案号:鲁ICP备2024069028号-1 客服联系 QQ:2149211541

×
保存成功