接触网实习报告班级:姓名:学号:2013年11月2目录第一章接触网的组成··············································3(一)接触悬挂··················································3(二)定位装置··················································3(三)支持装置··················································3(四)支柱与基础················································4第二章接触网下部工程············································5(一)测量······················································5(二)基坑定位··················································6(三)基础浇注··················································7(四)拉线······················································8第三章接触网上部工程············································9(一)腕臂柱····················································9(二)软横跨····················································11实习总结·························································14参考文献·························································153第一章接触网的组成(一)接触悬挂接触悬挂包括接触线、吊弦、承力索和补偿装置以及连接零件。接触悬挂通过支持装置架设在支柱上,其作用是将从牵引变电所获得的电能送给电力机车。接触悬挂应满足下列要求:1、接触线悬挂的弹性应尽量均匀;2、接触线对轨面的高度应尽量相等,接触线高度变化应避免出现陡坡;3、接触悬挂在受电弓压力及风力作用下应有良好的稳定性;4、接触悬挂的结构及零部件应力求轻巧简单,做到标准化。具有一定的抗腐蚀能力和耐磨性。接触悬挂分为简单接触悬挂和链型悬挂。简单悬挂是系由一根接触线直接固定在支柱支持装置上的悬挂形式。国内外对简单悬挂做了不少研究和改进。我国现采用的带补偿装置的弹性简单悬挂系在接触线下锚处装设了张力补偿装置,以调节张力和弛度的变化。在悬挂点上加装8~16m长的弹性吊索,通过弹性吊索悬挂接触线,这就减少了悬挂点处产生的硬点,改善了取流条件。另外跨距适当缩小,增大接触线的张力去改善弛度对取流的影响。链型悬挂接触线是通过吊弦悬挂在承力索上。承力索悬挂于支柱的支持装置上,使接触线在不增加支柱的情况下增加了悬挂点,利用调整吊弦长度,使接触线在整个跨距内对轨面的距离保持一致。链形悬挂减小了接触线在跨距中间的弛度,改善了弹性,增加了悬挂重量,提高了稳定性,可以满足电力机车高速运行取流的要求。(二)定位装置定位装置包括定位管、定位器、支持器、定位线夹及连接零件。其功用是固定接触线的位置,使接触线在受电弓滑板运行轨迹范围内,保证接触线与受电弓不脱离,并将接触线的水平负荷传给支柱。(三)支持装置支持装置包括腕臂(又称斜腕臂)、水平压管(又称平腕臂)帮是绝缘子及其他建筑物的特殊支持设备。支持装置用以支持接触悬挂,并将其负荷传给支柱或其他建筑物。4支持装置的结构应能适应各种场所,尽量轻巧耐用,有足够的机械强度,方便施工和检修。根据接触网所在区间、站场和大型建筑物而有所不同。支持装置结构图如下:(四)支柱与基础支柱与基础用以承受接触悬挂、支持和定位装置的全部负荷,并将接触悬挂固定在规定的位置和高度上。基础是对钢支柱而言的。我国接触网中采用预应力钢筋混凝土支柱和钢柱,基础是对钢支柱而言的,即钢支柱固定在下面的钢筋混凝土制成的基础上,由基础承受支柱传给的全部负荷,并保证支柱的稳定性。预应力钢筋混凝土支柱与基础制成一个整体,下端直接埋入地下。支柱是接触网中最基本、应用最广泛的支撑设备,用来承受接触悬挂与支持设备的负荷。接触网支柱,按其使用材质分为预应力钢筋混凝土支柱和钢支柱两大类。预应力钢筋混凝土支柱,简称为钢筋混凝土支柱采用高强度的钢筋,在制造时预先使钢筋产生拉力,它比普通钢筋混凝土支柱在同等容量情况下节省钢材、强度大、支柱轻等优点。钢筋混凝土支柱本身是一个整体结构,不需另制基础。钢柱以角钢焊成架结构,具有支柱较轻、强度高、抗碰撞、安装运输方便等优点。根据安装使用地点不同,钢柱的型号规格及外形结构也不同。支柱按其在接触网中的作用可分为中间支柱、转换支柱、中心支柱、锚柱、定位支柱道岔支柱、软横跨支柱、硬横跨支柱及桥梁支柱等几种。5第二章接触网下部工程(一)测量1、钢卷尺的使用使用钢卷尺时,一只手握住尺盒,另一只手食指和拇指卡住尺头弯曲部位拉出卷尺。测量时,要以钢卷尺的弯曲端边为基准,钢卷尺与被测物件位置应放正,横向要水平,竖向要垂直。2、经纬仪的使用第一步,假设仪器。将经纬仪放置在架头上,使架头大致水平,旋紧连接螺旋。第二步,对中。使仪器中心与测站点位于同一铅垂线上。可以移动脚架,旋转脚螺栓使对中标志准确对准测站点的中心。第三步,整平。使仪器竖轴铅垂。水平度盘水平。根据水平角的定义,是两条方向线的夹角在水平面上的投影,所以水平度盘一定要水平。粗平:伸缩脚架腿,使圆水准气泡居中。检查并精确对中:检查对中标志是否偏离地面点。如果偏离了,旋松三角架桑德连接螺栓,平移仪器基座使对中标志准确队总测站点的中心,拧紧连接螺栓。精平:旋转脚螺旋,使管水准旗袍居中。第四步,瞄准与读数。目镜对光:目镜调焦使十字丝清晰。瞄准和物镜对光:粗瞄目标,物镜调焦使目标清晰。注意消除视差。精瞄目标。读数:调整照明反光镜,使度数窗亮度适中,旋转度数显微镜的目镜刻度线清晰,然后读数。3、丁字尺的使用将丁字尺放在靠支柱侧的钢轨上,贴紧钢轨内沿,丁字尺上“0”刻度线应与钢轨内沿重合,丁字尺另一端应紧贴支柱边缘,水平尺放在丁字尺上,用水平尺保持丁字尺水平即可读数。测量方法:(1)在接触网平面图中找出测量起点或相邻站1号、2号道岔位置,并做出标记。(2)由起测点或相邻站1号、2号道岔位置出发,按平时图中标注的跨距值,沿支柱邻近的钢轨外侧,使用钢卷尺拉链,确定支柱纵向位置。(3)在确定的位置处,先用粉笔做出标记,然后在粉笔标记点处的轨腰上做出标记,定测后先用白漆刷底,然后用红漆标上标记6(4)当测量到曲线处,在曲线直缓点用丁字尺将测量点转移到曲线外侧钢轨上继续测量(5)用测量绳测出软(硬)横跨杆位点的正线的垂线或曲线切线的法线(二)基坑定位通过对皮尺、丁字尺、线坠、测量绳等工具的正确使用,采用科学、合理、安全可靠的方法,最终完成基坑定位。1、皮尺的使用:使用皮尺测量时,皮尺头部的铁环要平直,所测尺寸要从铁环头算起。测量大型物件或长距离时,横向要水平,纵向与横向要垂直。定位方法:(1)一句平面图复核轨腰上的测量标记,找出支持中心线的位置。(2)将丁字尺至于轨面上,并对准支柱中心线标记,然后将丁字尺用水平尺找平。(3)从丁字尺上确定出基坑内、外缘中心(4)过丁字尺上确定的基坑内、外缘中点作路中心线平行线,然后用粉笔作出标记(5)以内、外缘中心为基点,基坑宽的一半为基长在两平行线上截取四点,用粉笔连接这四点即为基坑轮廓线(6)在距基坑轮廓线1m且在内,外缘延长线上钉辅助木桩,桩心钉铁钉。2、注意事项:(1)一个站场应尽量一次测完,不宜分批分段侧脸,以免造成大量返工,测量时应遵循以下原则:“先测道岔区,后测股道区;先测控制柱,后测一般柱,软(硬)横跨柱应成对定位“。(2)测量中,对重点杆位应注意校核。(3)在站场测量总,应在测量区段的两端各设防护人员,密切注意来往车辆,尤其注意溜车。(4)禁止用钢卷尺进行横向拉链,以免造成轨道电路被短接。(5)遇有土质松软易坍塌地带,在确定基坑时,需加大坑口尺寸,以满足基坑加设防护的需要。7(三)基础浇注1、混凝土的基本常识混凝土,一般是指用水泥作胶结材料,按一定配合比掺加沙子、石子和水,搅拌均匀后经过硬化而形成的材料,又称人造石材。混凝土可采用人工和机械搅拌。所用的水泥、沙子、石子和水必须根据施工配合比要求量取,搅拌必须均匀。倒入模型内的混凝土必须用捣固器或捣固铲捣实,待初凝后覆盖湿草袋加以养护。养护时间:采用普通水泥为10—14天;火山灰和矿渣水泥为14—21天。混凝土的强度是指单位面积上所能承受的最大压力,是以标准制成品在15—20摄氏度温度下养护28天的抗压强度值来表示。接触网混凝土基础强度标号为110、150和170号;钢筋混凝土支柱为400和500号;横卧板、锚板和底板为200号。影响混凝土强度的因素很多,主要的是水灰比。2、基础类型基础按外形分类,目前常见的有工字形、锥形、单阶梯型、多阶梯型四种。一般用于13m钢柱的基础多采用单阶梯型基础,用于15m钢柱的基础多采用多阶梯型基础,土壤承压力在0.39MPa以上的基坑中经常采用工字形基础,锥形基础较少采用。3、浇注工艺(1)按照限界、方向、高差的要求安装模型板。(2)将砂子倒在钢板上,再将水泥倒在砂子上,然后作业人员将砂子和水泥搅拌两遍。(3)将石子倒入拌好的水泥砂子中,用铁锹将它们干拌三遍,然后逐渐加入适量的水并搅拌三遍。(4)在基础的最低层铺上00mm厚的碎石垫层并铺平,然后将混凝土灌注到模型板内(混凝土自由倾落高度超过3m时,采用串筒或溜槽下落)(5)振捣器发动机启动以后,自然垂直或斜向插入混凝土中3—5cm进行振捣20—30s直到混凝土不再显著下沉,不再发生气泡,表面平整并出现水泥浆,外观均匀时停8止。(6)混凝土凝固2h以后将草袋盖到浇注完毕的基础上并浇上适量的水。(7)养护天以后拆除模型板,修补基础表面窝坑,然后将土回填到基础周围。(四)拉线通过对皮尺、紧线器、扳手、断线钳等工具的正确使用,掌握拉线坑的定位、拉线的安装方法,采用科学、合理、安全可靠的方式,最终完成拉线的安装。1、支柱除承受垂直线路的负荷外,还要承受接触悬挂下锚的负荷因此锚柱承载很大。为了使锚柱稳定,一般采用锚柱打拉线,用以平衡下锚悬挂张力对支柱产生的影响。下锚拉线设在锚支的延长线上,若因地形限制应按设计要求施工。拉线(拉线锚杆)与地平面的夹角宜为45度,特殊困难地区不应大于60度,拉线锚板坑深应能保证锚板埋深设计值(以地面最低处算,宜为2m)。拉线采用GJ-70钢绞线,通过UT型线夹与锚板拉杆连接,拉杆的下端用U型螺栓与锚板连接,拉线的另一端则固定在支柱上的承锚角钢处。2、安装工艺(1)作业人员站在与锚段相邻的转换柱中心线与线路中心线的交点处,通过锚柱中心目测一条直线,另一名作业人员从锚柱起始,在直线上丈量10.4m,此定点即为拉线坑中心(2)用铁锹开挖拉线坑,坑口尺寸为长1.2m、宽0.6m、坑深2m(3)利用棕绳将锚板放入拉线坑中,地锚杆放入马道中,并使短杆向上。(4)锚板安设后,回填拉线坑并夯实。(5)作业人员上支柱将拉线固定角钢安装到锚柱上距地面13.4m左右处。(6)将预制完毕的拉线的回头楔形线夹与拉线固定角钢用销钉连接牢固,然后在距地锚杆2—3m处拉线上安装楔形紧线器,并在紧线器受力侧前安装1—2个钢线卡子。(7)在地锚杆环中挂上钢丝套,将双钩紧线器的双钩与钢丝套和楔形紧线器套子连接。(8)紧动双钩紧线器使锚柱断头向拉线方向倾斜50—100mm后停止。(9)测量回头位置,并做好回头,然后安装UT型线夹,并使线夹螺栓的螺