建筑给排水计算书(范本)

整理文档很辛苦,赏杯茶钱您下走!

免费阅读已结束,点击下载阅读编辑剩下 ...

阅读已结束,您可以下载文档离线阅读编辑

资源描述

目录第一章室内冷水系统…………………………………………………….3一竖向分区…………………………………………………………..3二用水量标准及计算………………………………………………..3三冷水管网计算……………………………………………………..4四引入管及水表选择………………………………………………..9五屋顶水箱容积计算……………………………………………….10六地下贮水池容积计算…………………………………………….11七生活水泵的选择………………………………………………….11第二章室内热水系统……………………………………………………12一热水量及耗热量计算…………………………………………….12二热水配水管网计算……………………………………………….12三热水循环管网计算……………………………………………….15四循环水泵的选择………………………………………………….16五加热设备选型及热水箱计算…………………………………….17第三章建筑消火栓给水系统设计……………………………………..18一消火栓系统的设计计算………………………………………..18二消防水泵的选择………………………………………………..20三消防水箱设置高度确定及校核………………………………..20四消火栓减压……………………………………………………..20五消防立管与环管计算…………………………………………..21六室外消火栓与水泵接合器的选定……………………………..21第四章自动喷水灭火系统设计……………………………………….22一自动喷水灭火系统的基本设计数据……………………………22二喷头的布置与选用……………………………………………..22三水力计算………………………………………………………..22四水力计算………………………………………………………..23五自动喷水灭火系统消防泵的选择………………………………26第五章建筑灭火器配置设计………………………………………….28第六章建筑排水系统设计…………………………………………….29一排水管道设计秒流量…………………………………………..29二排水管网水力计算……………………………………………..29三化粪池设计计算………………………………………………..33四户外排水管设计计算…………………………………………..34第七章建筑雨水系统设计…………………………………………….35一雨水量计算……………………………………………………..35二水力计算………………………………………………………..36第一章室内冷水系统一.竖向分区本工程是一栋十二层高的综合建筑,给水分两个区供给。一、二、三层商场和办公室作为低区,由市政管网直接供水;三至十二层客房作为高区,由屋顶水箱供水。二.用水量标准及用水量计算1.确定生活用水定额qd及小时变化系数kh。根据原始资料中建筑物性质及卫生设备完善程度,按《建筑给水排水规范》确定用水定额和小时变化系数见下,未预见用水量高区按以上各项之和的15%计,低区按10%计。列于用水量表中。2.用水量公式:①最高日用水量Qd=Σmqd/1000式中Qd:最高日用水量,L/d;m:用水单位数,人或床位数;qd:最高日生活用水定额,L/人.d,L/床.d,或L/人.班。②最大小时生活用水量Qh=QdKh/T式中Qh:最大小时用水量,L/h;Qd:最高日用水量,L/d;T:24h;Kh:小时变化系数,按《规范》确定。⑴.高区用水量计算客房:用水单位数:324床;用水定额:400L/(床/d);时变化系数Kh=2;供水时间为24h最高日用水量Qd=324×400=129600L/d最高日最大时用水量Qh=Kh×Qd/24=10.8m3/h未预见水量:按15%计,时变化系数Kh=1.最高日用水量Qd=129600×15%=19400L/d最高日最大时用水量Qh=19400/24=0.81m3/h⑵.低区用水量计算办公:用水单位数:442×2×60%/7=76人用水定额50L/(人*班)时变化系数Kh=1.5供水时间8h最高日用水量Qd=76×50=3800L/d最高日最大时用水量Qh=Kh×Qd/8=0.71m3/h商场:用水单位数:384㎡用水定额8L/(日*班)时变化系数Kh=1.5供水时间12h最高日用水量Qd=384×8=3072L/d最高日最大时用水量Qh=Kh×Qd/12=0.38m3/h未预见水量按10%计,时变化系数Kh=1.最高日用水量Qd=3800+3072=6872L/d最高日最大时用水量Qh=6872/24=0.29m3/d三.冷水管网计算1.设计秒流量公式的确定根据卫生洁具当量数计算各管段设计秒流量,对于一般高层综合楼可采用《规范》公式:qg=0.2αgN式中:qg:计算管段的设计秒流量(L/s);Ng:计算管段的卫生器具给水当量总数;α:根据建筑物用途而定的系数。本设计中高区α取2.5,低区取1.5。说明:计算值小于该管段上一个卫生器具给水额定流量时,应采用一个最大的卫生器具给水额定流量作为设计秒流量。如计算值大于该管段上按卫生器具给水额定流量累加所得流量值时,应按卫生器具给水额定力量累加所得流量值采用。2.高区给水管网水力计算高区给水管网系统图见下:3#、4#、5#、6#卫生间平面图见下:高区给水系统列表计算立管有4根,分别是J1L-1,J1L-2,J1L-5,J1L-7,其余J1L-3、J1L-4同J1L-2,J1L-6、J1L-11同J1L-5,J1L-8、J1L-9、J1L-10同J1L-7。计算立管编号及节点编号见系统图,卫生间编号见平面图。局部水头损失按沿程水头损失的30%计。卫生间给水水力计算表管段编号管长卫生器具名称数量n/N当量设计秒流量管径流速ihy=il∑hyL/m浴盆坐便器洗脸盆总数Ngqg(L/s)De(mm)V(m/s)(kpa/m)(kpa)(kpa)1—20.51/1.010.2200.990.0940.0472—30.81/1.01/0.51.50.3250.920.0580.0474—31.51/0.50.50.1200.540.030.0453—00.31/1.01/0.51/0.520.45320.850.0380.0110.151—21.81/0.50.50.1200.540.030.0542—30.41/0.51/0.510.2250.610.0280.0114—30.51/1.010.2200.990.0940.0383—00.41/1.01/0.51/0.520.45320.850.0380.0153’—00.11/1.01/0.51/0.520.45320.850.0380.0040.1221—20.81/1.010.2200.990.0940.0752—30.21/1.01/0.51.50.3250.920.0580.0124—32.51/0.50.50.1200.540.030.0753—00.41/1.01/0.51/0.520.45320.850.0380.0150.1773’—00.11/1.01/0.51/0.520.45320.850.0380.0040.1661—21.81/0.50.50.1200.990.0940.1692—30.31/1.01/0.51.50.3250.920.0580.0174—34.51/0.50.50.1200.540.030.1353—00.21/1.01/0.51/0.520.45320.850.0380.0080.3293#卫生间4#卫生间5#卫生间6#卫生间给水立管水力计算表管段编号管长卫生器具名称数量n/N当量设计秒流量管径流速ihy=il∑hyL/m浴盆坐便器洗脸盆总数Ngqg(L/s)De(mm)V(m/s)(kpa/m)(kpa)(kpa)1—231/1.01/0.51/0.520.45320.850.0380.1142—332/1.02/0.52/0.541401.20.0550.1653—433/1.03/0.53/0.561.23500.940.0270.0814—534/1.04/0.54/0.581.41501.080.0350.1055—635/1.05/0.55/0.5101.38501.210.0430.1296—736/1.06/0.56/0.5121.73630.830.0170.057—837/1.07/0.57/0.5141.87630.90.0190.0578—938/1.08/0.58/0.5162630.960.0220.0659—102.659/1.09/0.59/0.5182.12631.020.0240.0640.831—2341401.20.0550.1652—3381.41501.080.0350.1053—43121.73630.830.0170.054—53162630.960.0220.0655—63202.24631.080.0270.086—73242.45631.180.0320.0957—83282.65631.280.0360.1098—93322.83750.830.0110.0339—102.65363750.880.0130.0340.736J1L-1J1L-5J1L-2J1L-7横干管水力计算管段编号管长卫生器具名称数量n/N当量设计秒流量管径流速ihy=il∑hyL/m浴盆坐便器洗脸盆总数Ngqg(L/s)De(mm)V(m/s)(kpa/m)(kpa)(kpa)1—23.7724.24751.240.0240.0892—33.71446901.220.0180.0673—41.852167.35901.490.0270.056—53.7363750.880.0130.0485—41.851085.2901.070.0140.0264—水箱1.532491101.180.0140.0210.33.低区给水管网水力计算低区给水管网系统图见下:低区给水管网水力计算管段编号管长卫生器具名称数量n/N当量设计秒流量管径流速ihy=il∑hyL/m小便斗蹲便器洗手盆总数Ngqg(L/s)De(mm)V(m/s)(kpa/m)(kpa)(kpa)低区男卫1—20.81/0.50.50.1200.5370.030.0242—30.82/0.510.2250.6120.02750.0223—40.83/0.51.50.3250.9180.05820.0474—55.074/0.520.4320.7530.030.1545—60.94/0.51/0.52.50.5320.9420.0460.0416—70.94/0.52/0.530.6321.130.06440.0587—80.94/0.53/0.53.50.7400.8390.02850.0268—93.64/0.54/0.540.8400.9580.03640.1319—1038/0.58/0.581.41501.0780.03490.10510—01.3512/0.512/0.5121.73501.3230.0510.0690.677低区女卫1—20.91/0.50.50.1200.5370.030.0272—30.92/0.510.2250.6120.02750.0253—40.93/0.51.50.3250.9180.05820.0524—50.654/0.520.4320.7530.030.026—711/0.50.50.1200.5370.030.037—50.72/0.510.2250.6120.02750.029—811/0.50.50.1200.5370.030.038—51.32/0.510.2250.6120.02750.0365—1034/0.54/0.540.8400.9580.03640.1110—1138/0.58/0.581.41501.0780.03490.10511—01.3512/0.512

1 / 37
下载文档,编辑使用

©2015-2020 m.777doc.com 三七文档.

备案号:鲁ICP备2024069028号-1 客服联系 QQ:2149211541

×
保存成功