羊台苑二期实体质量检测方案编制:审核:审批:二○一三年月日致:总监理工程师审核意见:项目监理机构(章):总监理工程师(注册章):年月日专业监理工程师(签名):年月日专业监理工程师审查意见:附件:(施工组织设计/方案)1份。总承包单位(项目章):项目负责人(注册章):年月日深圳市建控地盘监理有限公司(监理单位)我方已完成羊台苑二期实体质量检测方案安全专项施工方案的编制,并经公司技术负责人批准,请予以审查。施工组织设计(方案)报审表GDAQ21103工程名称:羊台苑二期编号:目录第一章工程概况··································································2第一节项目概况······························································2第二节建筑概况······························································2第三节现场平面布置··························································3第四节编制依据······························································4第二章结构实体检测······························································4第一节结构实体检测要求······················································4第二节结构实体检测··························································6第三节回弹··································································8第四节外观实测实量·························································12第五节检测结果的认定和处理措施·············································14第三章验证性检测方案···························································14第一节试件的制作要求·······················································14第二节混凝土强度检验·······················································14第三节钢筋保护层厚度检验···················································15第四节截面尺寸检验························································16第五节垂直度和表面平整度检验···············································17第六节本工程对钢筋保护层厚度的控制措施·····································17羊台苑二期实体质量检测施工方案深圳市鹏城建筑集团有限公司ShenzhenPengChengconstructiongroupCO.LTD第2页第一章工程概况第一节项目概况工程名称:羊台苑二期工程位置:宝安区石岩街道羊台山众兴路建设单位:深圳市东部开发(集团)有限公司设计单位:香港华艺设计顾问(深圳)有限公司监理单位:深圳市建控地盘监理有限公司质监单位:深圳市宝安区建设工程质量监督站安监单位:深圳市宝安区施工安全监督站施工单位:深圳市鹏城建筑集团有限公司第二节建筑概况1、羊台苑二期为保障性住房,位于深圳市宝安区石岩镇,由1-4栋塔楼及1栋幼儿园组成,如下表。序号层数/地上/地下地下室高度(m)标准层高度(m)建筑高度(m)建筑面积(m2)耐火等级1栋34/24.2/7.52.895.1515675.81一级2栋34/24.2/5.82.895.1515742.77一级3栋33/24.2/5.82.892.3517144.19一级4栋31/24.2/5.82.886.7514709.27一级5栋3/3.610.81712.46二级2、建筑特征:本工程1、2栋楼地上高度为95.15米、3栋楼地上高度为92.35米、4栋楼地上高度为86.75米、5栋幼儿园高度为10.80米;地下负二层层高为4.2米,负一层为4.2米至5.6米,1-4#楼标准层高2.8米,幼儿园层高3.6米,建筑面积:87786.38m2,其中地上建筑面积70669.72m2,(含核增面积239.72m2),地下为17126.66m23、使用功能:地上为商业网点、社区配套设施、住宅、幼儿园;地下为地下车库,设备用房。4、结构特征:⑴本工程位于深圳市石岩镇;1-4#楼为4栋高层住宅,地面以下为二层地下室5#楼1栋多层幼儿园,地面以下无地下室。⑵1-4#楼为框剪结构,5#楼为框架结构,设计使用年限为50年。⑶1-4#楼抗震设防类别为丙类、基础设计等级为甲级、人防抗力等级为核6级常6级;5#楼抗震羊台苑二期实体质量检测施工方案深圳市鹏城建筑集团有限公司ShenzhenPengChengconstructiongroupCO.LTD第3页设防类别为乙类、基础设计等级为乙级;1-5#楼建筑结构安全等级为二级、建筑物耐火等级为一级、建筑物场地类别为Ⅱ类场地、抗震设防烈度为七度、设计地震分组为第一组、地面粗糙度为C类,基本风压重现期50年为0.75KPa。5、现场道路:主大门作为施工车辆主要进出口,施工临时道路土方开挖前,用辗压机辗压平整,铺设15cm厚碎石道渣,然后从工地出入口大门至施工现场间的路面浇灌长50m厚20cm的C30混凝土路面;保证车辆出入方便安全,也有利于文明施工;基础土方开挖时,安排专人轮班在工地出入口冲洗土方运输车辆的轮胎,避免运输车辆轮胎的淤泥污染市容路面。第三节现场平面布置1、本工程布置两台塔吊,1#塔吊(TC6020,R=60m)布置2栋西侧,主要负责1、2#楼;2#塔吊(TC6013,R=60m)布置在4栋南侧,主要负责3、4#楼。2、本工程布置4台施工电梯,1栋1台、2栋1台、3栋1台、4栋1台。3、本工程悬挑式脚手架主要考虑塔楼悬挑层以上的结构及装修使用,需按照建筑外轮廓搭设,同时综合考虑塔吊、施工电梯等大型机械进行脚手架平面布置4、现场排水:现场排水主要考虑雨天地面雨水以及其它用水能迅速排除,并防止进入基坑;地面做成一定坡度,使水及时排向排水系统。5、材料、构件堆放:工地生活区前面的空地浇捣300㎡和现场的水泥路面,作为施工临时使用场地,作砂、碎石、水泥、砖和钢筋、模板等堆场,分类堆放并标识。6、机械布置:塔吊:主体结构施工所用TC6013塔吊布置于工程D栋前面,塔吊臂长60m,塔吊安装高度高于井架;设置井字架主要供砌筑材料、装饰材料等运输之用;砂浆搅拌机靠近井架、灰、砂堆场,还施工电梯配合运输。7、施工临时用电:根据施工机具用量计划,现场施工机械电动机、电焊机总功率为W=350kW,现场照明用电按动力用电的10%计算,则用电总量为:35KW(详细按临时用电施工组织设计);本工程施工临时用电,由建设单位配电房直接供给,工地用电用橡皮线由配电房接至现场配电箱。8、施工临时用水设计:羊台苑二期实体质量检测施工方案深圳市鹏城建筑集团有限公司ShenzhenPengChengconstructiongroupCO.LTD第4页水源:本工程施工队用水是公路边原设有城市自来水管,由建设单位负责引入施工现场;考虑到城市自来水供水管的压力情况,本工程由管网直接供水,2层以上用高压水泵向各层楼面供水,水量不够的情况下有备用深水井配合供应。9、临时设施:本工程临时设在工地范围内,场内办公室、员工宿舍、仓库、厨房、卫生间;现场移动板房和砌砖做法,符合防火要求,详见施工总平面布置图。第四节编制依据1、GB50300-2001《建筑工程施工质量验收统一标准》2、GBJ107-87《混凝土强度检验评定标准》3、GB50204-2002《混凝土结构工程施工质量验收规范》4、GB/T50344-2004《建筑结构检测技术标准》5、《建筑工程施工质量验收统一标准》(GB5020300-2001)6、《混凝土结构工程质量验收规范》(GB50204-2002)7、《工程测量规范》(GB50026-93)8、《混凝土强度检验评分标准》(GBJ107)9、《回弹法检测混凝土抗压强度技术规程》(JGJ/T23-2001)10、《混凝土质量控制标准》(GB50164)11、《建筑施工手册》第四版;12、工程建设标准强制性条文、及其他有关法律、法规、规章、管理文件。第二章结构实体检测第一节结构实体检测要求1、对涉及混凝土结构安全的重要部位应进行结构实体检验;结构实体检验应在监理工程师(建设单位项目专业技术负责人)见证下,由施工项目技术负责人组织实施。2、承担结构实体检验的试验室应具有相应的资质;本工程由深圳市建设工程质量检测站(实体检测)检测;结构实体检验的内容应包括混凝土强度、钢筋保护层厚度以及工程合同约定的项目;必要时可检验其他项目。3、对混凝土强度的检验,应以在混凝土浇筑地点制备并与结构实体同条件养护的试件强度为依据;混凝土强度检验用同条件养护试件的留置、养护和强度代表值应符合下列条件:⑴同条件养护试件所对应的结构构件或结构部位,应由业主、监理、施工等各方共同选定。羊台苑二期实体质量检测施工方案深圳市鹏城建筑集团有限公司ShenzhenPengChengconstructiongroupCO.LTD第5页⑵对混凝土结构工程中的各混凝土强度等级,均应留置同条件养护试件。⑶同一强度等级的同条件养护试件,其留置的数量应根据混凝土工程量和重要性确定,不宜少于10组,且不应少于3组。⑷混凝土强度实体检测:主体结构混凝土一般采用回弹法检测,混凝土碳化深度采用1%酚酞溶液和碳化深度检测仪检测;主体结构混凝土抽检的构件应具有代表性,抽检的楼层数不少于总数的1/3,混凝土抽检的数量,按不少于混凝土构件总数的10%且不少于3个,不同混凝土强度等级的混凝土应分别抽检。4、对钢筋保护层厚度的检验,抽样数量、检验方法、允许偏差和合格条件应符合下列要求:⑴钢筋保护层厚度检验的结构部位,应由业主、监理、施工等各方根据结构构件的重要性共同选定。⑵钢筋保护层厚度的检验,可采用破损或局部破损的方法,也可采用非破损方法并用局部破损方法进行校准;当采用非破损方法检验时,所使用的检测仪器应经过计量检验,检测操作应符合相应规程的规定,钢筋保护层厚度检测的检测误差不应大于1㎜,本工程采用专用钢筋扫描仪进行检测。⑶重点对梁、柱、板等的钢筋保护层厚度进行抽检,对梁类、板类构件,应各抽取构件数量的2%且不少于5个构件进行检验;当有悬挑构件时,抽取的构件中悬挑梁类、板类构件所占比例均不宜小于50%;具体做法见《混凝土结构工程施工质量验收规范》(GB50204-2002)附录E。⑷对选定的梁类构件,应对全部纵向受力钢筋的保护层厚度进行检验;对选定的板类构件,应抽取不少于6根纵向受力钢筋的保护层厚度进行检验;对每根钢筋,应在有代表性的部位测量1点。⑸钢筋保护层厚度检验时,纵向受力钢筋保护层厚度的允许偏差,对梁类构件为+10㎜,-7㎜;对板类构件为+8㎜,-5㎜。5、现浇板厚度检测:⑴选用钻孔尺量法;⑵抽检的现浇板应具有代表性,抽检的楼层数不少于总数的1/3,抽检的数量每层现浇扳一般抽检数量不少于1块,每块板随机尺量四个点;⑶采取钻孔尺量法检测现浇板厚度的钻孔直径宜为12